Source author record

Luca Marmugi

Luca Marmugi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2020arXiv

Sub-Sm$^{-1}$ electromagnetic induction imaging with an unshielded atomic magnetometer

Progress in electromagnetic induction imaging with atomic magnetometers has brought its domain to the edge of the regime useful for biomedical imaging. However, a demonstration of imaging below the required 1 Sm$^{-1}$ level is still missing. In this Letter, we use an $^{87}$Rb radio-frequency atomic magnetometer operating near room temperature in an unshielded environment to image calibrated solutions mimicking the electric conductivity of live tissues. By combining the recently introduced near-resonant imaging technique with a dual radio-frequency coil excitation scheme, we image 5 mL of solutions down to 0.9 Sm$^{-1}$. We measure a signal-to-noise ratio of 2.7 at 2 MHz for 0.9 Sm$^{-1}$, increased up to 7.2 with offline averaging. Our work is an improvement of 50 times on previous imaging results, and demonstrates the sensitivity and stability in unshielded environments required for imaging biological tissues, in particular for the human heart.

preprint2016arXiv

Compact setup for the production of $^{87}$Rb $|F = 2, m_F = +2\rangle$ Bose-Einstein condensates in a hybrid trap

We present a compact experimental apparatus for Bose-Einstein condensation of $^{87}$Rb in the $|F = 2, m_F = +2\rangle$ state. A pre-cooled atomic beam of $^{87}$Rb is obtained by using an unbalanced magneto-optical trap, allowing controlled transfer of trapped atoms from the first vacuum chamber to the science chamber. Here, atoms are transferred to a hybrid trap, as produced by overlapping a magnetic quadrupole trap with a far-detuned optical trap with crossed beam configuration, where forced radiofrequency evaporation is realized. The final evaporation leading to Bose-Einstein condensation is then performed by exponentially lowering the optical trap depth. Control and stabilization systems of the optical trap beams are discussed in detail. The setup reliably produces a pure condensate in the $|F = 2, m_F = +2\rangle$ state in 50 s, which include 33 s loading of the science magneto-optical trap and 17 s forced evaporation.

preprint2016arXiv

Electromagnetic Imaging with Atomic Magnetometers: A Novel Approach to Security and Surveillance

We describe our research programme on the use of atomic magnetometers to detect conductive objects via electromagnetic induction. The extreme sensitivity of atomic magnetometers at low frequencies, up to seven orders of magnitude higher than a coil-based system, permits deep penetration through different media and barriers, and in various operative environments. This eliminates the limitations usually associated with electromagnetic detection.

preprint2016arXiv

Electromagnetic induction imaging with a radio-frequency atomic magnetometer

We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future generation of imaging instruments, which combine magnetic induction tomography and the unmatched performance of atomic magnetometers.

preprint2016arXiv

Optical atomic magnetometry for magnetic induction tomography of the heart

We report on the use of radio-frequency optical atomic magnetometers for magnetic induction tomography measurements. We demonstrate the imaging of dummy targets of varying conductivities placed in the proximity of the sensor, in an unshielded environment at room-temperature and without background subtraction. The images produced by the system accurately reproduce the characteristics of the actual objects. Furthermore, we perform finite element simulations in order to assess the potential for measuring low-conductivity biological tissues with our system. Our results demonstrate the feasibility of an instrument based on optical atomic magnetometers for magnetic induction tomography imaging of biological samples, in particular for mapping anomalous conductivity in the heart.

preprint2015arXiv

Photo-induced modifications of the substrate-adsorbate interaction in K-loaded porous glass

The effects of visible and infrared light on potassium atoms embedded in a nanoporous glass matrix are investigated. Photodesorption by visible light enhances the atomic mobility and causes the formation of metallic nanoparticles. Two different populations of metastable clusters with absorption bands in the near-infrared and infrared are grown as a consequence of illumination. Atoms can move between the two groups through sequences of adsorption/desorption events at the pore surface. Irradiation with infrared light, instead, does not significantly enhance the atomic diffusion inside the pores. However, it induces relevant modifications of the substrate, thus changing its interaction with the assembled clusters. Consequently, infrared light alters the dynamics of the system, affecting also the evolution of non-resonant nanoparticles populations, even after the illumination sequence. These results provide new insights on the photo-induced modifications of the substrate-adsorbate interaction in nano-sized confined systems.

preprint2014arXiv

Magnetic induction tomography using an all-optical $^{87}$Rb atomic magnetometer

We demonstrate Magnetic Induction Tomography (MIT) with an all-optical atomic magnetometer. Our instrument creates a conductivity map of conductive objects. Both shape and size of the imaged samples compare very well with the actual shape and size. Given the potential of all-optical atomic magnetometers for miniaturization and extreme sensitivity, the proof-of-principle presented here opens up promising avenues in the development of instrumentation for magnetic induction tomography.