Researcher profile

Fernando Sparasci

Fernando Sparasci contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Active suppression of temperature oscillation from a pulse-tube cryocooler in a cryogen-free cryostat: Part 1. Simulation modeling from thermal response characteristics

A cryogen-free cryostat cooled using a 4 K commercial GM or pulse tube cryocooler (PTC) displays temperature oscillations caused by the intrinsic working principle of the regenerative cryocooler. To dampen such oscillations usually requires either a large heat capacity or a large thermal resistance. To understand this phenomenon better and suppress it more effectively, both the step response characteristic and the intrinsic oscillation characteristic of cryostat have been used to obtain the complete transfer functions of a simulation model. The latter is used to test and optimize traditional PID feedback control. The results showed this approach has almost no effect on the temperature oscillation amplitude. Based on this simulation model, a novel active method was proposed and tested numerically. Simulation results predict the method should suppress the amplitude of the original temperature oscillation by a factor of two.

preprint2020arXiv

Active suppression of temperature oscillation from a pulse-tube cryocooler in a cryogen-free cryostat: Part 2. Experimental realization

A cryogen-free cryostat cooled by a closed cycle cryocooler is compact, can provide uninterrupted long-term operation (up to ten thousand hours) and is suited to temperatures from 3 K to 300 K. Its intrinsic temperature oscillation, however, limits its application in experiments requiring high thermal stability at low temperature (below 77 K). Passive suppression methods are effective but all suffer from drawbacks. We describe a novel, active suppression scheme more efficient than traditional proportional-integral (PI) control. The experimental results show that it can reduce the standard deviation of the temperature oscillation by a further 30% compared with PI feedback. To the best of our knowledge, this is the first time such active suppression of temperature oscillations has been implemented with the cryogen-free cryostat. The results also show, however, that an unwanted lower frequency thermal noise will be generated, which appears to be the limit of the method. Nevertheless, the approach could be used to improve the temperature stability in all cryogen-free cryostats.

preprint2020arXiv

Comparison of ITS-90 realizations from 13 K to 273 K between LNE-CNAM and INRIM

Since Key Comparison CCT-K2, only few comparisons on realizations of cryogenic fixed points have been carried out, be they bilateral (three, of which one still pending) or multilateral (two trilateral). Since a forthcoming general follow-up is unlikely, any bilateral comparison, not only key comparisons, is most welcome to provide evidence of the continuing thermometric capabilities of the laboratories involved in the realization of the ITS-90. Not too long after the creation in 2018 of the Joint Research Laboratory for Fluid Metrology Evangelista Torricelli between LNE-CNAM and INRIM, the two laboratories agreed to perform a bilateral comparison at all the cryogenic fixed points of the scale between 13 K and 273 K, including the two hydrogen vapour-pressure temperatures required for the full platinum resistance thermometer range 3.3.1 of the ITS-90. The results are reported here and show a substantial agreement, within the combined uncertainties.

preprint2012arXiv

Copper passivation procedure for water-filled copper cells for applications in metrology

In the framework of the European research project MeteoMet, the LNE-CNAM and the LNE-CETIAT are developing novel copper cells for the determination of the water vapour pressure equation and the measurement of the triple point of water temperature at the highest degree of accuracy. The Water Vapour Pressure Equation (WVPE) is the basic formula for the calculation of the vapour pressure and other humidity related quantities. Improvement in the uncertainty of the water vapour formulation in the temperature range between -80^{\cdot}C (and possibly down to -90^{\cdot}C) and +100^{\cdot}C is needed for the improvement of primary standards in the field of hygrometry. The Triple Point of Water (TPW, temperature 273,16 K) plays a key role in thermometry, because of its threefold function. On one side, it defines the temperature unit, the kelvin. On the other side, it is the reference point in Standard Platinum Resistance Thermometer (SPRT) calibrations, according to the International Temperature Scale of 1990 (ITS-90). Finally, it is the connection point between the current definition of the kelvin and the future one, based on the Boltzmann constant. Copper cells for WVPE and TPW allow highly accurate temperature control, fast thermal response time and excellent thermal uniformity, because of the elevated copper thermal conductivity. Thus, they can be an outstanding tool for reducing measurement uncertainty. Nevertheless, accurate filling techniques and procedures are necessary, to minimize water contamination and get stable, accurate and reproducible results. This report describes the filling system and the copper passivation and cleaning procedure, as well as the method for filling copper cells with high-purity water.