Researcher profile

Ercang Luo

Ercang Luo contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

Active suppression of temperature oscillation from a pulse-tube cryocooler in a cryogen-free cryostat: Part 1. Simulation modeling from thermal response characteristics

A cryogen-free cryostat cooled using a 4 K commercial GM or pulse tube cryocooler (PTC) displays temperature oscillations caused by the intrinsic working principle of the regenerative cryocooler. To dampen such oscillations usually requires either a large heat capacity or a large thermal resistance. To understand this phenomenon better and suppress it more effectively, both the step response characteristic and the intrinsic oscillation characteristic of cryostat have been used to obtain the complete transfer functions of a simulation model. The latter is used to test and optimize traditional PID feedback control. The results showed this approach has almost no effect on the temperature oscillation amplitude. Based on this simulation model, a novel active method was proposed and tested numerically. Simulation results predict the method should suppress the amplitude of the original temperature oscillation by a factor of two.

preprint2020arXiv

Active suppression of temperature oscillation from a pulse-tube cryocooler in a cryogen-free cryostat: Part 2. Experimental realization

A cryogen-free cryostat cooled by a closed cycle cryocooler is compact, can provide uninterrupted long-term operation (up to ten thousand hours) and is suited to temperatures from 3 K to 300 K. Its intrinsic temperature oscillation, however, limits its application in experiments requiring high thermal stability at low temperature (below 77 K). Passive suppression methods are effective but all suffer from drawbacks. We describe a novel, active suppression scheme more efficient than traditional proportional-integral (PI) control. The experimental results show that it can reduce the standard deviation of the temperature oscillation by a further 30% compared with PI feedback. To the best of our knowledge, this is the first time such active suppression of temperature oscillations has been implemented with the cryogen-free cryostat. The results also show, however, that an unwanted lower frequency thermal noise will be generated, which appears to be the limit of the method. Nevertheless, the approach could be used to improve the temperature stability in all cryogen-free cryostats.

preprint2020arXiv

Prediction and realization of a temperature control limit at low temperatures in SPRIGT

On May 20th 2019, the World Metrology Day, the Bureau International des Poids et Mesures announced a major revision to the four more SI units. The base unit, the kelvin, is defined by fixing the value of Boltzmann constant as indicated in Mise en pratique for the definition of the kelvin in the SI. To realize the new kelvin, a novel practical realization technique of single-pressure refractive-index gas thermometry (SPRIGT) has been jointly developed by the TIPC-CAS in China and the LNE-Cnam in France. To carry out accurate SPRIGT, experimental methods have been implemented and micro-kelvin level temperature control limits have been predicted and achieved at 5 K to 26 K. The resonator temperature stability can be maintained to within better than 8 μK of its set point with an integration time 33.6 s over 180 h. Besides, solutions for further improving the stability were also demonstrated, which can be a reference for temperature metrology field worldwide and other fields where high-stability temperature is required. The present work should also provide a solid foundation for international data comparison of thermodynamic temperature at low temperatures, and will promote realizations of the new kelvin and the spread of high-accuracy, low-temperature metrology.

preprint2020arXiv

Realization of ppm level pressure stability for primary thermometry using a primary piston gauge

To achieve an uncertainty of 0.25 mK in single-pressure refractive-index gas thermometry (SPRIGT), the relative pressure variation of He-4 gas in the range 30 kPa to 90 kPa, should not exceed 4 ppm (k=1). To this end, a novel pressure control system has been developed. It consists of two main parts: a piston gauge to control the pressure, and a home-made gas compensation system to supplement the micro-leak of the piston gauge. In addition, to maintain the piston at constant height, a servo loop is used that automatically determines in real time the amount of extra gas required. At room temperature, the standard deviations of the stabilized pressure are 3.0 mPa at 30 kPa, 4.5 mPa at 60 kPa and 2 mPa at 90 kPa. For the temperature region 5 K-25 K used for SPRIGT in the present work, the relative pressure stability is better than 0.16 ppm i.e. 25 times better than required. Moreover, the same pressure stabilization system is readily transposable to other primary gas thermometers.

preprint2020arXiv

Resonance frequency measurement with accuracy and stability at the 10-12 level in a copper microwave cavity below 26 K by experimental optimization

Single pressure refractive index gas thermometry (SPRIGT) is a novel primary thermometry, jointly developed by TIPC of CAS in China and LNE-Cnam in France. To realize a competitive uncertainty of 0.25 mK for thermodynamic temperature measurements, high-stability and low-uncertainty of microwave resonance frequency measurements better than 2 ppb should be achieved. This article describes how to realize high-stability and low-uncertainty of resonance frequency measurements in a copper microwave cavity by experimental optimization methods based on Allan analysis of variance. In this manner, 10-12 level accuracy and stability of microwave resonance frequency measurements were realized with an integration time of 3 hours, which is nearly 20 times better than those without optimization in our previous work (Sci. Bull 2019; 64: 286-288). It has potential applications in gas metrology and other research fields, where high-stability and low-uncertainty microwave measurements are necessary. Besides, microwave measurements were carried out isobarically at pressures of (30, 60, 90, and 120) kPa over the temperature range of (5 to 26) K, with good microwave mode consistency for the determined thermodynamic temperatures. These will provide strong support for the success of the implementation of SPRIGT in China.