Source author record

F. v. Feilitzsch

F. v. Feilitzsch appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

21works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

21 published item(s)

preprint2022arXiv

EXCESS workshop: Descriptions of rising low-energy spectra

Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.

preprint2022arXiv

Probing spin-dependent dark matter interactions with $^6$Li

CRESST is one of the most prominent direct detection experiments for dark matter particles with sub-GeV/c$^2$ mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of $^{6}$Li. This is now possible thanks to new calculations on nuclear matrix elements of this specific isotope of Li. To show the potential of using this particular nuclide for probing dark matter interactions, we used the data collected previously by a CRESST prototype based on LiAlO$_2$ and operated in an above ground test-facility at Max-Planck-Institut für Physik in Munich, Germany. In particular, the inclusion of $^{6}$Li in the limit calculation drastically improves the result obtained for spin-dependent interactions with neutrons in the whole mass range. The improvement is significant, greater than two order of magnitude for dark matter masses below 1 GeV/c$^2$, compared to the limit previously published with the same data.

preprint2020arXiv

Description of CRESST-III Data

In CRESST-III, 10 cryogenic detector modules optimized for low energy thresholds were operated for almost two years (May 2016 - February 2018). Together with this document we are publishing data from the best performing detector module which has a nuclear recoil threshold of 30.1eV. With this data-set we were able to set limits on the cross-section for spin-dependent and spin-independent elastic scattering of dark matter particles off nuclei at dark matter masses down to 160MeV/c$^2$. We publish the energies of all events after data selection as well as of all events within the acceptance region for dark-matter searches. In this document we describe how to use these data sets.

preprint2019arXiv

First results on sub-GeV spin-dependent dark matter interactions with $^{7}$Li

In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.

preprint2016arXiv

A detector module with highly efficient surface-alpha event rejection operated in CRESST-II Phase 2

The cryogenic dark matter experiment CRESST-II aims at the direct detection of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals. We present a new, highly improved, detector design installed in the current run of CRESST-II Phase 2 with an efficient active rejection of surface-alpha backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target crystal, a detector housing with fully-scintillating inner surface could be realized. The presented detector (TUM40) provides an excellent threshold of ${\sim}\,0.60\,$keV and a resolution of $σ\,{\approx}\,0.090$ keV (at 2.60$\,$keV). With significantly reduced background levels, TUM40 sets stringent limits on the spin-independent WIMP-nucleon scattering cross section and probes a new region of parameter space for WIMP masses below 3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the surface-alpha event rejection in detail.

preprint2016arXiv

Beta/gamma and alpha backgrounds in CRESST-II Phase 2

The experiment CRESST-II aims at the detection of dark matter with scintillating CaWO$_4$ crystals operated as cryogenic detectors. Recent results on spin-independent WIMP-nucleon scattering from the CRESST-II Phase 2 allowed to probe a new region of parameter space for WIMP masses below 3 GeV/c$^2$. This sensitivity was achieved after background levels were reduced significantly. We present extensive background studies of a CaWO$_4$ crystal, called TUM40, grown at the Technische Universität München. The average beta/gamma rate of 3.51/[kg keV day] (1-40 keV) and the total intrinsic alpha activity from natural decay chains of $3.08\pm0.04$ mBq/kg are the lowest reported for CaWO$_4$ detectors. Contributions from cosmogenic activation, surface-alpha decays, external radiation and intrinsic alpha/beta emitters are investigated in detail. A Monte-Carlo based background decomposition allows to identify the origin of the majority of beta/gamma events in the energy region relevant for dark matter search.

preprint2016arXiv

Energy-Dependent Light Quenching in CaWO$_4$ Crystals at mK Temperatures

Scintillating CaWO$_4$ single crystals are a promising multi-element target for rare-event searches and are currently used in the direct Dark Matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers). The relative light output of different particle interactions in CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an active background discrimination and the identification of a possible signal induced by weakly interacting massive particles (WIMPs). We present the first precise measurements of the QFs of O, Ca and W at mK temperatures by irradiating a cryogenic detector with a fast neutron beam. A clear energy dependence of the QF of O and, less pronounced, of Ca was observed for the first time. Furthermore, in CRESST neutron-calibration data a variation of the QFs among different CaWO$_4$ single crystals was found. For typical CRESST detectors the QFs in the region-of-interest (10-40$\,$keV) are $QF_O^{ROI}=(11.2{\pm}0.5)\,$%, $QF_{Ca}^{ROI}=(5.94{\pm}0.49)\,$% and $QF_W^{ROI}=(1.72{\pm}0.21)\,$%. The latest CRESST data (run32) is reanalyzed using these fundamentally new results on light quenching in CaWO$_4$ having moderate influence on the WIMP analysis. Their relevance for future CRESST runs and for the clarification of previously published results of direct Dark Matter experiments is emphasized.

preprint2016arXiv

Limits on momentum-dependent asymmetric dark matter with CRESST-II

The usual assumption in direct dark matter searches is to only consider the spin-dependent or spin-independent scattering of dark matter particles. However, especially in models with light dark matter particles $\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the momentum transfer $q^2$ can become dominant. One such model based on asymmetric dark matter has been invoked to overcome discrepancies in helioseismology and an indication was found for a particle with preferred mass of 3 $\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data from the CRESST-II experiment, which uses cryogenic detectors based on $\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter particles, are used to constrain these momentum-dependent models. The low energy threshold of 307 eV for nuclear recoils of the detector used, allows us to rule out the proposed best fit value above.

preprint2016arXiv

New Limits on Double Electron Capture of $^{40}$Ca and $^{180}$W

We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Depending on the process, these values improve the currently best limits by a factor of $\sim$1.4-30.

preprint2016arXiv

Results on light dark matter particles with a low-threshold CRESST-II detector

The CRESST-II experiment uses cryogenic detectors to search for nuclear recoil events induced by the elastic scattering of dark matter particles in CaWO$_4$ crystals. Given the low energy threshold of our detectors in combination with light target nuclei, low mass dark matter particles can be probed with high sensitivity. In this letter we present the results from data of a single detector module corresponding to 52 kg live days. A blind analysis is carried out. With an energy threshold for nuclear recoils of 307 eV we substantially enhance the sensitivity for light dark matter. Thereby, we extend the reach of direct dark matter experiments to the sub-region and demonstrate that the energy threshold is the key parameter in the search for low mass dark matter particles.

preprint2015arXiv

Impact of Coherent Neutrino Nucleus Scattering on Direct Dark Matter Searches based on CaWO$_4$ Crystals

Atmospheric and solar neutrinos scattering coherently off target nuclei will be an important background source for the next generation of direct dark matter searches. In this work we focus on calcium tungstate as target material. For comparison with existing works we calculate the neutrino floor indicating which sensitivities can be reached before the neutrino background appears. In addition, we investigate the sensitivities of future direct dark matter searches using CRESST-II like detectors. Extending previous works we take into account achievable energy resolutions and thresholds as well as beta and gamma backgrounds for this investigation. We show that an exploration of WIMP-nucleon cross sections below the neutrino floor is possible for exposures of $\gtrsim10$ kg-years or higher. In the third part we show that a first detection of coherent neutrino nucleus scattering of atmospheric and solar neutrinos using the same detectors and the backgrounds is feasible for exposures of $\gtrsim50$ kg-years.

preprint2015arXiv

Microscopic Model for the Scintillation-Light Generation and Light-Quenching in CaWO$_4$ single crystals

Scintillators are employed for particle detection and identification using light-pulse shapes and light quenching factors. We developed a comprehensive model describing the light generation and quenching in CaWO$_4$ single crystals used for direct dark matter search. All observed particle-dependent light-emission characteristics can be explained quantitatively, light-quenching factors and light-pulse shapes are calculated on a microscopic basis. This model can be extended to other scintillators such as inorganic crystal scintillators, liquid noble gases or organic liquid scintillators.

preprint2015arXiv

Probing low WIMP masses with the next generation of CRESST detector

The purpose of this document is to describe the upgrade of the CRESST dark matter search at LNGS. The proposed strategy will allow to explore a region of the parameter space for spin-independent WIMP-nucleon elastic scattering corresponding to WIMP masses below 10GeV/c$^\text{2}$, that has not been covered by other experiments. These results can be achieved only with outstanding detector performances in terms of threshold and background. This proposal shows how CRESST can match these performance requirements, adding a unique piece of information to the dark matter puzzle. The results of this program will fix a new state-of-the-art in the low mass WIMP exploration, opening new perspectives of understanding the dark matter scenario.

preprint2015arXiv

Results on low mass WIMPs using an upgraded CRESST-II detector

The CRESST-II cryogenic dark matter search aims for the detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from a low-threshold analysis of a single upgraded detector module. This module efficiently vetoes low energy backgrounds induced by $α$-decays on inner surfaces of the detector. With an exposure of \unit[29.35]{kg live days} collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering which probes a new region of parameter space for WIMP masses below \unit[3]{GeV/c$^2$}, previously not covered in direct detection searches. A possible excess over background discussed for the previous CRESST-II phase 1 (from 2009 to 2011) is not confirmed.

preprint2015arXiv

The CRESST Dark Matter Search - Status and Perspectives

In the past years the spotlight of the search for dark matter particles widened to the low mass region, both from theoretical and experimental side. We discuss results from data obtained in 2013 with a single detector TUM40. This detector is equipped with a new upgraded holding scheme to efficiently veto backgrounds induced by surface alpha decays. This veto, the low threshold of 0.6keV and an unprecedented background level for CaWO$_4$ target crystals render TUM40 the detector with the best overall performance of CRESST-II phase 2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate light dark matter particles (<3GeV/c$^2$), previously not accessible for other direct detection experiments.

preprint2014arXiv

Neganov-Luke amplified cryogenic light detectors for the background discrimination in neutrinoless double beta decay search with TeO$_{2}$ bolometers

We demonstrate that Neganov-Luke amplified cryogenic light detectors with Transition Edge Sensor read-out can be applied for the background suppression in cryogenic experiments searching for the neutrinoless double beta decay of $^{130}\text{Te}$ with TeO$_{2}$ based bolometers. Electron and gamma induced events can be discriminated from $α$ events by detecting the Cherenkov light produced by the $β$ particles emitted in the decay. We use the Cherenkov light produced by events in the full energy peak of $^{208}\text{Tl}$ and by events from a $^{147}\text{Sm}$ source to show that at the Q-value of the neutrinoless double beta decay of $^{130}\text{Te}$ ($Q_{ββ} = 2.53 \,\text{MeV}$), a separation of $e^{-}/γ$ events from $α$ events can be achieved on an event-by-event basis with practically no reduction in signal acceptance.

preprint2014arXiv

Radiopurity of CaWO$_4$ Crystals for Direct Dark Matter Search with CRESST and EURECA

The direct dark matter search experiment CRESST uses scintillating CaWO$_4$ single crystals as targets for possible WIMP scatterings. An intrinsic radioactive contamination of the crystals as low as possible is crucial for the sensitivity of the detectors. In the past CaWO$_4$ crystals operated in CRESST were produced by institutes in Russia and the Ukraine. Since 2011 CaWO$_4$ crystals have also been grown at the crystal laboratory of the Technische Universität München (TUM) to better meet the requirements of CRESST and of the future tonne-scale multi-material experiment EURECA. The radiopurity of the raw materials and of first TUM-grown crystals was measured by ultra-low background $γ$-spectrometry. Two TUM-grown crystals were also operated as low-temperature detectors at a test setup in the Gran Sasso underground laboratory. These measurements were used to determine the crystals' intrinsic $α$-activities which were compared to those of crystals produced at other institutes. The total $α$-activities of TUM-grown crystals as low as 1.23 $\pm$ 0.06 mBq/kg were found to be significantly smaller than the activities of crystals grown at other institutes typically ranging between ~15 mBq/kg and ~35 mBq/kg.

preprint2012arXiv

Influence of Annealing on the Optical and Scintillation Properties of CaWO$_4$ Single Crystals

We investigate the influence of oxygen annealing on the room temperature optical and scintillation properties of CaWO$_4$ single crystals that are being produced for direct Dark Matter search experiments. The applied annealing procedure reduces the absorption coefficient at the peak position of the scintillation spectrum ($\sim430$ nm) by a factor of $\sim6$ and leads to an even larger reduction of the scattering coefficient. Furthermore, the annealing has no significant influence on the \emph{intrinsic} light yield. An additional absorption occurring at $\sim400$ nm suggests the formation of O$^-$ hole centers. Light-yield measurements at room temperature where one crystal surface was mechanically roughened showed an increase of the \emph{measured} light yield by $\sim40 %$ and an improvement of the energy resolution at 59.5 keV by $\sim12 %$ for the annealed crystal. We ascribe this result to the reduction of the absorption coefficient while the surface roughening is needed to compensate for the also observed reduction of the scattering coefficient after annealing.

preprint2012arXiv

Low-Temperature Light Detectors: Neganov-Luke Amplification and Calibration

The simultaneous measurement of phonons and scintillation light induced by incident particles in a scintillating crystal such as CaWO4 is a powerful technique for the active rejection of background induced by gamma's and beta's and even neutrons in direct Dark Matter searches. However, less than ~1% of the energy deposited in a CaWO4 crystal is detected as light. Thus, very sensitive light detectors are needed for an efficient event-by-event background discrimination. Due to the Neganov-Luke effect, the threshold of low-temperature light detectors based on semiconducting substrates can be improved significantly by drifting the photon-induced electron-hole pairs in an applied electric field. We present measurements with low-temperature light detectors based on this amplification mechanism. The Neganov-Luke effect makes it possible to improve the signal-to-noise ratio of our light detectors by a factor of ~9 corresponding to an energy threshold of ~21 eV. We also describe a method for an absolute energy calibration using a light-emitting diode.

preprint2011arXiv

Neutrino oscillometry at the next generation neutrino observatory

The large next generation liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) offers an excellent opportunity for neutrino oscillometry. The characteristic spatial pattern of very low monoenergetic neutrino disappearance from artificial radioactive sources can be detected within the long length of detector. Sufficiently strong sources of more than 1 MCi activity can be produced at nuclear reactors. Oscillometry will provide a unique tool for precise determination of the mixing parameters for both active and sterile neutrinos within the broad mass region 0.01 - 2 (eV)^2. LENA can be considered as a versatile tool for a careful investigation of neutrino oscillations.