Source author record

Eugen Wiens

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
3topics
4close collaborators

Published work

2 publications

preprint2020arXiv

A simplified cryogenic optical resonator apparatus providing ultra-low frequency drift

A system providing an optical frequency with an instability comparable to that of a hydrogen maser is presented. It consists of a 55 cm\mathrm{cm} long, vertically oriented silicon optical resonator operated at temperatures between 1.51.5 K\mathrm{K} and 3.63.6 K\mathrm{K} in a closed-cycle cryostat with low-temperature Joule-Thomson stage. We show that with a standard cryostat, a simple cryogenic optomechanical setup, no active or passive vibration isolation, a minimum frequency instability of 2.5×10−152.5\times10^{-15} at τ=1500τ=1500 s\mathrm{s} integration time can be reached. The influence of pulse-tube vibrations was minimized by using a resonator designed for low acceleration sensitivity. With reduced optical laser power and interrogation duty cycle an ultra-low fractional frequency drift of −2.6×10−19-2.6\times10^{-19}/s\mathrm{s} is reached. At 3.53.5 K\mathrm{K} the resonator frequency exhibits a vanishing thermal sensitivity and an ultra-small temperature derivative 8.5×10−12/K28.5\times10^{-12}/\mathrm{K}^{2}. These are favorable properties that should lead to high performance also in simpler cryostats not equipped with a Joule-Thomson stage.

preprint2014arXiv

A silicon single-crystal cryogenic optical resonator

We report on the demonstration and characterization of a silicon optical resonator for laser frequency stabilization, operating in the deep cryogenic regime at temperatures as low as 1.5 K. Robust operation was achieved, with absolute frequency drift less than 20 Hz over 1 hour. This stability allowed sensitive measurements of the resonator thermal expansion coefficient (αα). We found α=4.6×10−13α=4.6\times10^{-13} K−1{\rm K^{-1}} at 1.6 K. At 16.8 K αα vanishes, with a derivative equal to −6×10−10-6\times10^{-10} K−2{\rm K}^{-2}. The temperature of the resonator was stabilized to a level below 10 μμK for averaging times longer than 20 s. The sensitivity of the resonator frequency to a variation of the laser power was also studied. The corresponding sensitivities and the expected Brownian noise indicate that this system should enable frequency stabilization of lasers at the low-10−1710^{-17} level.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.