Source author record

E. Romano

E. Romano appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.

preprint2021arXiv

Modeling the triple-GEM detector response to background particles for the CMS Experiment

An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.

preprint2020arXiv

A comparison between scintillation light Analog and Digital trigger for large volume Liquid Argon Time Projection Chambers

Large volume Liquid Argon Time Projection Chambers (LAr-TPC) are used and proposed for neutrino physics and rare event search. Most of these detectors make use of the scintillation light of liquid argon for trigger purposes. Two different approaches can be adopted to provide these detectors with an effective trigger system, relying upon analog or digital processing of signal coming from photodetectors, like photomultiplier tubes or silicon photomultipliers. Each method presents advantages and drawbacks, so the implementation of a hybrid solution can benefit from both approaches. To this purpose, an innovative electronic board prototype has been designed and proposed for the use in large volume LAr-TPC detectors.

preprint2020arXiv

Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.

preprint2011arXiv

On the exponent of a finite group admitting a fixed-point-free four-group of automorphisms

Let $A$ be a group isomorphic with either $S_4$, the symmetric group on four symbols, or $D_8$, the dihedral group of order 8. Let $V$ be a normal four-subgroup of $A$ and $α$ an involution in $A\setminus V$. Suppose that $A$ acts on a finite group $G$ in such a manner that $C_G(V)=1$ and $C_G(α)$ has exponent $e$. We show that if $A\cong S_4$ then the exponent of $G$ is $e$-bounded and if $A\cong D_8$ then the exponent of the derived group $G'$ is $e$-bounded. This work was motivated by recent results on the exponent of a finite group admitting an action by a Frobenius group of automorphisms.

preprint2010arXiv

Industrially Scalable Process for Silicon Nanowires for Seebeck Generators

The observation that the thermal conductivity of single-crystalline silicon nanowires with diameter on the length scale of 25 nm is lower than that of bulk material by two orders of magnitude has attracted the interest onto silicon as a potentially effective thermoelectric material. However, the potential interest has a hope of transforming in a practical interest only if poly-crystalline silicon can replace single crystalline silicon and the preparation of nanowires does not involve any advanced photolithography. In this work we show that a technique, based on the controlled etching and filling of recessed regions and employing standard photolithography and deposition-etching methods, succeeds in the preparation of poly-crystalline silicon nanowires (with diameter of 25 nm and length on the centimetre scale) at a linear density of 3E6 cm^-1.