Source author record

E. Previtali

E. Previtali appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

57works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

57 published item(s)

preprint2022arXiv

An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

preprint2022arXiv

European Strategy for Particle Physics -- Accelerator R&D Roadmap

The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.

preprint2022arXiv

High precision measurement of the half-life of the 391.6 keV metastable level in 239Pu

Materials selection for rare event physics requires high performance detectors and customized analyses. In this context a novel $β$-$γ$ detection system, comprised of a liquid scintillator in coincidence with a HPGe, was developed with the main purpose of studying ultra trace contamination of uranium, thorium and potassium in liquid samples. In the search for $^{238}\textrm{U}$ contaminations through neutron activation analysis, since the activation product $^{239}\textrm{Np}$ decays to a relatively long-lived isomeric state of $^{239}\textrm{Pu}$, it is possible to perform a time selection of these events obtaining a strong background suppression. Investigating the time distribution of the coincidences between the $β^-$ decay of $^{239}\textrm{Np}$ and the delayed events following the de-excitation of the $^{239}\textrm{Pu}$ isomeric level at 391.6 keV, a precision measurement of the half-life of this level was conducted. The half-life of the 391.6 keV $^{239}\textrm{Pu}$ level resulted $190.2 \pm 0.2$ ns, thus increasing the precision by about a factor of 20 over previous measurements.

preprint2022arXiv

Measurements of neutron fields in a wide energy range using multi-foil activation analysis

An accurate characterization of the neutron fields at spallation sources is crucial for many applications based on neutron irradiations, such as radiation damage tests that need a precise dose estimate. In this work we present the neutron flux measurements performed with the multi-foil activation technique in the ROTAX and ChipIr beamlines of the ISIS spallation source, characterized by moderated and unmoderated spectra, respectively. We selected many different activation reactions to cover a wide energy range, from thermal to very fast neutrons up to about 100 MeV. By applying a Bayesian unfolding algorithm, we demonstrate the effectiveness of this technique in measuring the neutron flux intensity and energy spectrum with precision and accuracy.

preprint2022arXiv

New measurement of double beta decays of $^{100}$Mo to excited states of $^{100}$Ru with the CUPID-Mo experiment

The CUPID-Mo experiment, located at Laboratoire Souterrain de Modane (France), was a demonstrator experiment for CUPID. It consisted of an array of 20 Li$_2^{100}$MoO$_4$ (LMO) calorimeters each equipped with a Ge light detector (LD) for particle identification. In this work, we present the result of a search for two-neutrino and neutrinoless double beta decays of $^{100}$Mo to the first 0$^+$ and $2^+$ excited states of $^{100}$Ru using the full CUPID-Mo exposure (2.71 kg$\times$yr of LMO). We measure the half-life of $2νββ$ decay to the $0^{+}_1$ state as $T_{1/2}^{2ν\rightarrow 0_1^+}=7.5\pm 0.8 \ \text{(stat.)} \ ^{+ 0.4}_{-0.3} \ \text{(syst.)} )\times 10^{20} \ \mathrm{yr}$. The bolometric technique enables measurement of the electron energies as well as the gamma rays from nuclear de-excitation and this allows us to set new limits on the two-neutrino decay to the $2_1^+$ state of $T^{2ν\rightarrow 2_1^+}_{1/2}>4.4\times 10^{21} \ \mathrm{yr} \ \text{(90 % c.i.)}$ and on the neutrinoless modes of $T_{1/2}^{0ν\rightarrow 2_1^+}>2.1\times10^{23} \ \mathrm{yr}\ \text{(90 % c.i.)}$, $T_{1/2}^{0ν\rightarrow 0_1^+}>1.2\times10^{23} \ \mathrm{yr}\ \text{(90 % c.i.)}$. Information on the electrons spectral shape is obtained which allows us to make the first comparison of the single state (SSD) and higher state (HSD) $2νββ$ decay models for the $0_1^+$ excited state of $^{100}$Ru.

preprint2022arXiv

Optimization of the first CUPID detector module

CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.

preprint2022arXiv

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 νββ$) decay. Here we show results from the search for $0 νββ$ decay of $^{130}$Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for $0 νββ$ decay and set a lower bound of $T_{1/2}^{0 ν} > 2.2 \times 10^{25}$ years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.

preprint2022arXiv

Search for Neutrinoless $β^+EC$ Decay of $^{120}$Te with CUORE

CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay ($0νββ$) in $^{130}$Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than $^{130}$Te. In this work we describe a search for neutrinoless positron emitting electron capture ($0νβ^+EC$) decay in $^{120}$Te with a total TeO$_2$ exposure of 355.7 kg $\cdot$ yr, corresponding to 0.2405 kg $\cdot$ yr of $^{120}$Te. Albeit $0 νββ$ with two final state electrons represents the most promising channel, the emission of a positron and two 511-keV $γ$s make $0νβ^+EC$ decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of $3.4 \cdot 10^{22}$ yr at 90% Credibility Interval (C.I.). After unblinding we find no evidence of $0νβ^+EC$ signal and set a 90% C.I. Bayesian lower limit of $2.9 \cdot 10^{22}$ yr on $^{120}$Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

preprint2022arXiv

Toward CUPID-1T

Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years$)$ and $m_{ββ}\lesssim15$~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of $0\mathrm{νββ}$. We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond $0\mathrm{νββ}$, all moving toward the next-to-next generation CUPID-1T detector.

preprint2021arXiv

New results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0νββ$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0νββ$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0νββ$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0νββ$ decay half-life. In this work, we present the current status of CUORE's search for $0νββ$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2νββ$) decay half-life.

preprint2020arXiv

Double Beta Decay APPEC Committee Report

This report constitutes the roadmap document prepared by the Double Beta Decay APPEC Committee for the APPEC SAC on the future neutrinoless double beta decay experimental programme in Europe. It reviews the existing, planned and proposed technologies for neutrinoless double beta decay, their discovery potential and technical challenges, making a critical examination of resources and schedules. It also provides a concise discussion of the theoretical issues and of the status and uncertainties on the nuclear matrix element evaluation.

preprint2020arXiv

Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector

To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.

preprint2020arXiv

Search for double $β$-decay modes of $^{64}$Zn using purified zinc

The production of ultra-pure raw material is a crucial step to ensure the required background level in rare event searches. In this work, we establish an innovative technique developed to produce high-purity (99.999%) granular zinc. We demonstrate the effectiveness of the refining procedure by measuring the internal contaminations of the purified zinc with a high-purity germanium detector at the Laboratori Nazionali del Gran Sasso. The total activity of cosmogenic activated nuclides is measured at the level of a few mBq/kg, as well as limits on naturally occurring radionuclides are set to less than mBq/kg. The excellent radiopurity of the zinc sample allows us to search for electron capture with positron emission and neutrinoless double electron capture of $^{64}$Zn, setting the currently most stringent lower limits on their half-lives, $T_{1/2}^{\varepsilonβ^+} > 2.7 \times 10^{21}\text{yr}$ (90% C.I.), and $T_{1/2}^{0\nu2\varepsilon}> 2.6 \times 10^{21}\text{yr}$ (90% C.I.), respectively.

preprint2020arXiv

Search for Neutrino-less Double Beta Decay of $^{64}$Zn and $^{70}$Zn with CUPID-0

CUPID-0 is the first pilot experiment of CUPID, a next-generation project searching for neutrino-less double beta decay. In its first scientific run, CUPID-0 operated 26 ZnSe cryogenic calorimeters coupled to light detectors in the underground Laboratori Nazionali del Gran Sasso. In this work, we analyzed a ZnSe exposure of 11.34 kg$\times$yr to search for the neutrino-less double beta decay of $^{70}$Zn and for the neutrino-less positron-emitting electron capture of $^{64}$Zn. We found no evidence for these decays and set 90$\%$ credible interval limits of ${\rm T}_{1/2}^{0νββ}(^{70}{\rm Zn}) > 1.6 \times 10^{21}$ yr and ${\rm T}_{1/2}^{0νEC β+}(^{64}{\rm Zn}) > 1.2 \times 10^{22}$ yr, surpassing by almost two orders of magnitude the previous experimental results

preprint2019arXiv

Evidence of Single State Dominance in the Two-Neutrino Double-$β$ Decay of Se-82 with CUPID-0

We report on the measurement of the two-neutrino double-$β$ decay of $^{82}$Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0~experiment. With an exposure of 9.95 kg$\times$yr of Zn$^{82}$Se, we determine the two-neutrino double-$β$ decay half-life of $^{82}$Se with an unprecedented precision level, $T_{1/2}^{2ν} = [8.60 \pm 0.03 \textrm{(stat.)}~^{+0.17}_{-0.10} \textrm{(syst.)}] \times 10^{19}~\textrm{yr}$. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5 $σ$.

preprint2019arXiv

First data from the CUPID-Mo neutrinoless double beta decay experiment

The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both heat and scintillation light signals allows the efficient discrimination of $α$ from $γ$&$β$ events. In this proceedings, we discuss results from the first 2 months of data taking in spring 2019. In addition to an excellent bolometric performance of 6.7$\,$keV (FWHM) at 2615$\,$keV and an $α$ separation of better than 99.9\% for all detectors, we report on bulk radiopurity for Th and U. Finally, we interpret the accumulated physics data in terms of a limit of $T_{1/2}^{0ν}\,> 3\times10^{23}\,$yr for $^{100}$Mo and discuss the sensitivity of CUPID-Mo until the expected end of physics data taking in early 2020.

preprint2019arXiv

Improved Limit on Neutrinoless Double-Beta Decay in $^{130}$Te with CUORE

We report new results from the search for neutrinoless double-beta decay in $^{130}$Te with the CUORE detector. This search benefits from a four-fold increase in exposure, lower trigger thresholds and analysis improvements relative to our previous results. We observe a background of $(1.38\pm0.07)\cdot10^{-2}$ counts$/($keV$\cdot$kg$\cdot$yr$)$ in the $0νββ$ decay region of interest and, with a total exposure of 372.5 kg$\cdot$yr, we attain a median exclusion sensitivity of $1.7\cdot10^{25}$ yr. We find no evidence for $0νββ$ decay and set a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the $^{130}$Te half-life for this process. In the hypothesis that $0νββ$ decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.

preprint2019arXiv

Precise measurement of $2νββ$ decay of $^{100}$Mo with the CUPID-Mo detection technology

We report the measurement of the two-neutrino double-beta ($2νββ$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2ν}=[7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}]\times10^{18}$ years. This is the most accurate determination of the $2νββ$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3σ$, that the single-state dominance model of the $2νββ$ decay of $^{100}$Mo is favored over the high-state dominance model.

preprint2019arXiv

The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects

CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo. In this article, we detail the CUPID-Mo detector concept, assembly, installation in the underground laboratory in Modane in 2018, and provide results from the first datasets. The demonstrator consists of an array of 20 scintillating bolometers comprised of $^{100}$Mo-enriched 0.2 kg Li$_2$MoO$_4$ crystals. The detectors are complemented by 20 thin cryogenic Ge bolometers acting as light detectors to distinguish $α$ from $γ$/$β$ events by the detection of both heat and scintillation light signals. We observe good detector uniformity, facilitating the operation of a large detector array as well as excellent energy resolution of 5.3 keV (6.5 keV) FWHM at 2615 keV, in calibration (physics) data. Based on the observed energy resolutions and light yields a separation of $α$ particles at much better than 99.9\% with equally high acceptance for $γ$/$β$ events is expected for events in the region of interest for $^{100}$Mo $0νββ$. We present limits on the crystals' radiopurity ($\leq$3 $μ$Bq/kg of $^{226}$Ra and $\leq$2 $μ$Bq/kg of $^{232}$Th). Based on these initial results we also discuss a sensitivity study for the science reach of the CUPID-Mo experiment, in particular, the ability to set the most stringent half-life limit on the $^{100}$Mo $0νββ$ decay after half a year of livetime. The achieved results show that CUPID-Mo is a successful demonstrator of the technology - developed in the framework of the LUMINEU project - selected for the CUPID experiment, a proposed follow-up of CUORE, the currently running first tonne-scale cryogenic $0νββ$ experiment.

preprint2018arXiv

Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0

We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.

preprint2016arXiv

Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive $0νββ$ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final $0νββ$ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized $0νββ$ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the $0νββ$ decay half-life limits previously reported for CUORE-0, $T^{0ν}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino limit, $T^{0ν}_{1/2}>4.0\times10^{24}$ yr.

preprint2016arXiv

Cerenkov light identification with Si low-temperature detectors with Neganov-Luke effect-enhanced sensitivity

A new generation of cryogenic light detectors exploiting Neganov-Luke effect to enhance the thermal signal has been used to detect the Cherenkov light emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism a high significance event-by-event discrimination between alpha and beta/gamma interactions at the $^{130}$Te neutrino-less double beta decay Q-value - (2527.515 $\pm$ 0.013) keV - has been demonstrated. This measurement opens the possibility of drastically reducing the background in cryogenic experiments based on TeO$_{2}$.

preprint2016arXiv

CUORE-0 detector: design, construction and operation

The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.

preprint2016arXiv

First array of enriched Zn$^{82}$Se bolometers to search for double beta decay

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in $^{82}$Se, the Zn$^{82}$Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn$^{82}$Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

preprint2016arXiv

Steps towards the hyperfine splitting measurement of the muonic hydrogen ground state: pulsed muon beam and detection system characterization

The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the test were the characterization of the target, the hodoscope and the X-ray detectors. The apparatus consisted of a beam hodoscope and X-rays detectors made with high purity Germanium and Lanthanum Bromide crystals. In this paper the experimental setup is described and the results of the detector characterization are presented.

preprint2015arXiv

CUORE-0 results and prospects for the CUORE experiment

With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of 130Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1 sigma (9.5E25 y at the 90% confidence level), in five years of live time, corresponding to an upper limit on the effective Majorana mass in the range 40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric detectors could improve CUORE sensitivity and competitiveness of bolometric detectors towards a full analysis of the inverted neutrino mass hierarchy. CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g each, arranged in a 13 floor structure) constructed strictly following CUORE recipes both for materials and assembly procedures. An experiment its own, CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta decay half-life of 130Te around 3E24 y in one year of live time. We present an update of the data, corresponding to an exposure of 18.1 kg y. An analysis of the background indicates that the CUORE performance goal is satisfied while the sensitivity goal is within reach.

preprint2015arXiv

Double-beta decay investigation with highly pure enriched $^{82}$Se for the LUCIFER experiment

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of $^{82}$Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched $^{82}$Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3\% enriched $^{82}$Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of $^{232}$Th, $^{238}$U and $^{235}$U are respectively: $<$61 $μ$Bq/kg, $< $110 $μ$Bq/kg and $<$74 $μ$Bq/kg at 90\% C.L.. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the $^{82}$Se allowed us to establish the most stringent lower limits on the half-lives of double-beta decay of $^{82}$Se to 0$^+_1$, 2$^+_2$ and 2$^+_1$ excited states of $^{82}$Kr of 3.4$\cdot$10$^{22}$ y, 1.3$\cdot$10$^{22}$ y and 1.0$\cdot$10$^{22}$ y, respectively, with a 90\% C.L..

preprint2015arXiv

JUNO Conceptual Design Report

The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4$σ$, and determine neutrino oscillation parameters $\sin^2θ_{12}$, $Δm^2_{21}$, and $|Δm^2_{ee}|$ to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high quantum efficiency provide $\sim$75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.

preprint2015arXiv

Large area Si low-temperature light detectors with Neganov-Luke effect

Next generation calorimetric experiments for the search of rare events rely on the detection of tiny amounts of light (of the order of 20 optical photons) to discriminate and reduce background sources and improve sensitivity. Calorimetric detectors are the simplest solution for photon detection at cryogenic (mK) temperatures. The development of silicon based light detectors with enhanced performance thanks to the use of the Neganov-Luke effect is described. The aim of this research line is the production of high performance detectors with industrial-grade reproducibility and reliability.

preprint2015arXiv

Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0

We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times 10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of $^{130}$Te and place a Bayesian lower bound on the decay half-life, $T^{0ν}_{1/2}>$~$ 2.7\times 10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0ν}_{1/2} > 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, $m_{ββ}< 270$ -- $760~\mathrm{meV}$.

preprint2015arXiv

Searching for neutrinoless double-beta decay of $^{130}$Te with CUORE

Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detector will contain 206 kg of $^{130}$Te and have an average energy resolution of 5 keV; the projected $0νββ$ decay half-life sensitivity after five years of live time is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). In this paper we review the experimental techniques used in CUORE as well as its current status and anticipated physics reach.

preprint2015arXiv

Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments

CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/keV/kg/y will be reached, in five years of data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0 is a smaller experiment constructed to test and demonstrate the performances expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

preprint2015arXiv

The CUORE and CUORE-0 Experiments at Gran Sasso

The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0νββ$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\% C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to test and demonstrate the performances expected for CUORE, has been assembled and is running. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

preprint2014arXiv

CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy

The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). Further background rejection with auxiliary light detector can significantly improve the search sensitivity and competitiveness of bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and possibly other double beta decay candidate nuclei.

preprint2014arXiv

Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors

Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric 0nubb experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. We highlight the main challenges and identify priorities for an R&D program addressing them.

preprint2014arXiv

First bolometric measurement of the two neutrino double beta decay of $^{100}$Mo with a ZnMoO$_4$ crystals array

The large statistics collected during the operation of a ZnMoO$_4$ array, for a total exposure of 1.3 kg $\cdot$ day of $^{100}$Mo, allowed the first bolometric observation of the two neutrino double beta decay of $^{100}$Mo. The observed spectrum of each crystal was reconstructed taking into account the different background contributions due to environmental radioactivity and internal contamination. The analysis of coincidences between the crystals allowed the assignment of constraints to the intensity of the different background sources, resulting in a reconstruction of the measured spectrum down to an energy of $\sim$300 keV. The half-life extracted from the data is T$_{1/2}^{2ν}$= [7.15 $\pm$ 0.37 (stat) $\pm$ 0.66 (syst)] $\cdot$ 10$^{18}$ y.

preprint2014arXiv

Initial performance of the CUORE-0 experiment

CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.

preprint2013arXiv

Characterization of bolometric Light Detectors for rare event searches

Bolometers have proven to be very good detectors to search for rare processes thanks to their excellent energy resolution and their low intrinsic background. Further active background rejection can be obtained by the simultaneous readout of the heat and light signals produced by particles interacting in scintillating bolometers, as proposed by the LUCIFER experiment. In this framework, the choice of the light detector and the optimization of its working conditions play a crucial role. In this paper, we report a study of the performances of a Germanium bolometric light detector in terms of signal amplitude, energy resolution and signal time development. The impact of various operational parameters on the detector performances is discussed.

preprint2013arXiv

Performances of a large mass ZnSe bolometer to search for rare events

Scintillating bolometers of ZnSe are the baseline choice of the LUCIFER experiment, whose aim is to observe the neutrinoless double beta decay of 82Se. The independent read-out of the heat and scintillation signals allows to identify and reject alpha particle interactions, the dominant background source for bolometric detectors. In this paper we report the performances of a ZnSe crystal operated within the LUCIFER R&D. We measured the scintillation yield, the energy resolution and the background in the energy region where the signal from neutrinoless double beta decay of 82Se is expected with an exposure of 9.4 kg x days. With a newly developed analysis algorithm we improved the rejection of alpha events, and we estimated the increase in energy resolution obtained by the combination of the heat and light signals. For the first time we measured the light emitted by nuclear recoils, and found it to be compatible with zero. We conclude that the discrimination of nuclear recoils from beta/gamma interactions in the WIMPs energy region is possible, but low-noise light detectors are needed.

preprint2013arXiv

Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals

We report the results of a search for axions from the 14.4 keV M1 transition from Fe-57 in the core of the sun using the axio-electric effect in TeO2 bolometers. The detectors are 5x5x5 cm3 crystals operated at about 10 mK in a facility used to test bolometers for the CUORE experiment at the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg d of data was made using a newly developed low energy trigger which was optimized to reduce the detectors energy threshold. An upper limit of 0.63 c kg-1 d-1 was established at 95% C.L.. From this value, a lower bound at 95% C.L. was placed on the Peccei-Quinn energy scale of fa >= 0.76 10**6 GeV for a value of S=0.55 for the flavor-singlet axial vector matrix element. Bounds are given for the interval 0.15 < S < 0.55.

preprint2013arXiv

Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay

We present a study of the sensitivity and discovery potential of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity for various background scenarios are presented, and an extension of the sensitivity formulation to the discovery potential case is also discussed. Assuming a background rate of 10^-2 cts/(keV kg y), we find that, after 5 years of live time, CUORE has a 1 sigma sensitivity to the neutrinoless double-beta decay half-life of T_1/2(1 sigma) = 1.6 \times 10^26 y and thus a potential to probe the effective Majorana neutrino mass down to 40-100 meV; the sensitivity at 1.64 sigma, which corresponds to 90% C.L., will be T_1/2(1.64 sigma) = 9.5 \times 10^25 y. This range is compared with the claim of observation of neutrinoless double-beta decay in 76Ge and the preferred range of the neutrino mass parameter space from oscillation results.

preprint2013arXiv

The 4 K outer cryostat for the CUORE experiment: construction and quality control

The external shell of the CUORE cryostat is a large cryogen-free system designed to host the dilution refrigerator and the bolometers of the CUORE experiment in a low radioactivity environment. The three vessels that form the outer shell were produced and delivered to the Gran Sasso underground Laboratories in July 2012. In this paper, we describe the production techniques and the validation tests done at the production site in 2012.

preprint2013arXiv

The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments

We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data from the finished CUORICINO experiment. Finally, we report the expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers) experiments to a WIMP annual modulation signal.

preprint2012arXiv

Double-beta decay of $^{130}$Te to the first 0$^{+}$ excited state of $^{130}$Xe with CUORICINO

The CUORICINO experiment was an array of 62 TeO$_{2}$ single-crystal bolometers with a total $^{130}$Te mass of $11.3\,$kg. The experiment finished in 2008 after more than 3 years of active operating time. Searches for both $0ν$ and $2ν$ double-beta decay to the first excited $0^{+}$ state in $^{130}$Xe were performed by studying different coincidence scenarios. The analysis was based on data representing a total exposure of N($^{130}$Te)$\cdot$t=$9.5\times10^{25}\,$y. No evidence for a signal was found. The resulting lower limits on the half lives are $T^{2ν}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>1.3\times10^{23}\,$y (90% C.L.), and $T^{0ν}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>9.4\times10^{23}\,$y (90% C.L.).

preprint2012arXiv

New experimental limits on the alpha decays of lead isotopes

For the first time a PbWO4 crystal was grown using ancient Roman lead and it was run as a cryogenic detector. Thanks to the simultaneous and independent read-out of heat and scintillation light, the detector was able to discriminate beta/gamma interactions with respect to alpha particles down to low energies. New more stringent limits on the alpha decays of the lead isotopes are presented. In particular a limit of T_{1/2} > 1.4*10^20 y at a 90% C.L. was evaluated for the alpha decay of 204Pb to 200Hg.

preprint2012arXiv

Performances of a large mass ZnMoO4 scintillating bolometer for a next generation neutrinoless double beta decay experiment

We present the performances of a 330 g zinc molybdate (ZnMoO4) crystal working as scintillating bolometer as a possible candidate for a next generation experiment to search for neutrinoless double beta decay of 100Mo. The energy resolution, evaluated at the 2615 keV gamma-line of 208Tl, is 6.3 keV FWHM. The internal radioactive contaminations of the ZnMoO4 were evaluated as <6 microBq/kg (228Th) and 27\pm6 microBq/kg (226Ra). We also present the results of the alpha vs beta/gamma discrimination, obtained through the scintillation light as well as through the study of the shape of the thermal signal alone.

preprint2011arXiv

A novel technique of particle identification with bolometric detectors

We report in this paper the proofs that the pulse shape analysis can be used in some bolometers to identify the nature of the interacting particle. Indeed, while detailed analyses of the signal time development in purely thermal detectors have not produced so far interesting results, similar analyses on bolometers built with scintillating crystals seem to show that it is possible to distinguish between an electron or gamma-ray and an alpha particle interaction. This information can be used to eliminate background events from the recorded data in many rare process studies, especially Neutrinoless Double Beta decay search. Results of pulse shape analysis of signals from a number of bolometers with absorbers of different composition (CaMoO4, ZnMoO4, MgMoO4 and ZnSe) are presented and the pulse shape discrimination capability of such detectors is discussed.

preprint2011arXiv

CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background

The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been obtained for bulk contaminations and surface contaminations from several nuclides. An extrapolation to the CUORE background has been performed.

preprint2011arXiv

First measurement of the partial widths of $^{209}$Bi decay to the ground and to the first excited states

$^{209}$Bi alpha decay to the ground and to the first excited state have been contemporary observed for the first time with a large BGO scintillating bolometer. The half-life of $^{209}$Bi is determined to be $τ_{1/2}$=(2.01$\pm$0.08)$\cdot10^{19}$ years while the branching ratio for the ground-state to ground-state transition is (98.8$\pm$0.3)%.

preprint2011arXiv

Search for beta plus/EC double beta decay of 120Te

We present a search for beta plus/EC double beta decay of 120Te performed with the CUORICINO experiment, an array of TeO2 cryogenic bolometers. After collecting 0.0573 kg y of 120Te, we see no evidence of a signal and therefore set the following limits on the half-life: T1/2 (0nu) > 1.9 10^{21} y at 90% C.L. for the 0 neutrino mode and T1/2 (2nu) > 7.6 10^{19} y at 90% C.L. for the two neutrino mode. These results improve the existing limits by almost three orders of magnitude (four in the case of 0 neutrino mode).

preprint2010arXiv

130Te Neutrinoless Double-Beta Decay with CUORICINO

We report the final result of the CUORICINO experiment. Operated between 2003 and 2008, with a total exposure of 19.75 kg y of 130Te, CUORICINO was able to set a lower bound on the 130Te 0nDBD half-life of 2.8 10^{24} years at 90% C.L. The limit here reported includes the effects of systematic uncertainties that are examined in detail in the paper. The corresponding upper bound on the neutrino Majorana mass is in the range 300--710 meV, depending on the adopted nuclear matrix element evaluation.

preprint2010arXiv

CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors

We report the performances of a 0.51 kg CdWO4 scintillating bolometer to be used for future Double Beta Decay Experiments. The simultaneous read-out of the heat and the scintillation light allows to discriminate between different interacting particles aiming at the disentanglement and the reduction of background contribution, key issue for next generation experiments. We will describe the observed anticorrelation between the heat and the light signal and we will show how this feature can be used in order to increase the energy resolution of the bolometer over the entire energy spectrum, improving up to a factor 2.6 on the 2615 keV line of 208Tl. The detector was tested in a 433 h background measurement that permitted to estimate extremely low internal trace contaminations of 232Th and 238U. The light yield of gamma/beta, alpha and neutrons is presented. Furthermore we developed a method in order to correctly evaluate the absolute thermal quenching factor of alpha particles in scintillating bolometers.

preprint2010arXiv

Muon-induced backgrounds in the CUORICINO experiment

To better understand the contribution of cosmic ray muons to the CUORICINO background, 10 plastic scintillator detectors were installed at the CUORICINO site and operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV kg yr) (95% CL) was obtained on the cosmic ray-induced background in the neutrinoless double beta decay region of interest. The measurements were also compared to Geant4 simulations.

preprint2010arXiv

Production of high purity TeO2 single crystals for the study of neutrinoless double beta decay

High purity TeO2 crystals are produced to be used for the search for the neutrinoless double beta decay of 130Te. Dedicated production lines for raw material synthesis, crystal growth and surface processing were built compliant with radio-purity constraints specific to rare event physics experiments. High sensitivity measurements of radio-isotope concentrations in raw materials, reactants, consumables, ancillaries and intermediary products used for TeO2 crystals production are reported. Production and certification protocols are presented and resulting ready-to-use TeO2 crystals are described.

preprint2005arXiv

The Microcalorimeter Arrays for a Rhenium Experiment (MARE): a next-generation calorimetric neutrino mass experiment

Neutrino oscillation experiments have proved that neutrinos are massive particles, but can't determine their absolute mass scale. Therefore the neutrino mass is still an open question in elementary particle physics. An international collaboration is growing around the project of Microcalorimeter Arrays for a Rhenium Experiment (MARE) for directly measuring the neutrino mass with a sensitivity of about 0.2eV/c2. Many groups are joining their experiences and technical expertise in a common effort towards this challenging experiment. We discuss the different scenarios and the impact of MARE as a complement of KATRIN.

preprint2002arXiv

CUORE: A Cryogenic Underground Observatory for Rare Events

CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.