Source author record

Denzal Martin

Denzal Martin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Librational Feedback Cooling

Librational motion, whereby a rigid body undergoes angular oscillation around a preferred direction, can be observed in optically trapped, silica microspheres. We demonstrate the cooling of one librational degree of freedom for $\sim 5~μ$m diameter spheres that have been induced to rotate with an external electric field coupled to their electric dipole moment. Cooling is accomplished by adding a phase modulation to the rotating field. The degree of cooling is quantified by applying a $π/2$ shift to the phase of the electric field and fitting the resulting exponential decay of the librational motion to obtain a damping time, as well as estimating a mode temperature from the observed libration in equilibrium. The result is an important step in the study of the dynamics of trapped microspheres, crucial to cooling the mechanical motion to its ground state, as well as providing insights regarding the charge mobility in the material at microscopic scales.

preprint2020arXiv

Absolute pressure and gas species identification with an optically levitated rotor

The authors describe a novel variety of spinning-rotor vacuum gauge in which the rotor is a ${\sim}4.7{\text -}μ$m-diameter silica microsphere, optically levitated. A rotating electrostatic field is used to apply torque to the permanent electric dipole moment of the silica microsphere and control its rotational degrees of freedom. When released from a driving field, the microsphere's angular velocity decays exponentially with a damping time inversely proportional to the residual gas pressure, and dependent on gas composition. The gauge is calibrated by measuring the rotor mass with electrostatic co-levitation, and assuming a spherical shape, confirmed separately, and uniform density. The gauge is cross-checked against a capacitance manometer by observing the torsional drag due to a number of different gas species. The techniques presented can be used to perform absolute vacuum measurements localized in space, owing to the small dimensions of the microsphere and the ability to translate the optical trap in three dimensions, as well as measurements in magnetic field environments. In addition, the dynamics of the microsphere, paired with a calibrated vacuum gauge, can be used to measure the effective molecular mass of a gas mixture without the need for ionization and at pressures up to approximately 1 mbar.

preprint2020arXiv

High sensitivity, levitated microsphere apparatus for short-distance force measurements

A high sensitivity force sensor based on dielectric microspheres in vacuum, optically trapped by a single, upward-propagating laser beam, is described. Off-axis parabolic mirrors are used both to focus the 1064~nm trapping beam and to recollimate it to provide information on the horizontal position of the microsphere. The vertical degree of freedom is readout by forming an interferometer between the light retroreflected by the microsphere and a reference beam, hence eliminating the need for auxiliary beams. The focus of the trapping beam has a 1/e$^2$ radius of 3.2~$μ$m and small non-Gaussian tails, suitable for bringing devices close to the trapped microsphere without disturbing the optical field. Electrodes surrounding the trapping region provide excellent control of the electric field, which can be used to drive the translational degrees of freedom of a charged microsphere and the rotational degrees of freedom of a neutral microsphere, coupling to its electric dipole moment. With this control, the charge state can be determined with single electron precision, the mass of individual microspheres can be measured, and empirical calibrations of the force sensitivity can be made for each microsphere. A force noise of $<1\times10^{-17}$~N/$\sqrt{\rm Hz}$, which is comparable to previous reports, is measured on all three degrees of freedom for 4.7~$μ$m diameter, 84~pg silica microspheres. Various devices have been brought within $1.6~μ$m of the surface of a trapped microsphere. Metrology in the trapping region is provided by two custom-designed microscopes providing views in the horizontal and one of the vertical planes. The apparatus opens the way to performing high sensitivity three-dimensional force measurements at short distance.