Source author record

David R. Leibrandt

David R. Leibrandt appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

Rotational spectroscopy of a single molecular ion at sub part-per-trillion resolution

We use quantum-logic spectroscopy (QLS) and interrogate rotational transitions of a single CaH+ ion with a highly coherent frequency comb, achieving a fractional statistical uncertainty for a transition line center of 4 x 10^-13. We also improve the resolution in measurement of the Stark effect due to the radio-frequency (rf) electric field experienced by a molecular ion in an rf Paul trap, which we characterize and model. This allows us to determine the electric dipole moment of CaH+ by systematically displacing the ion to sample different known rf electric fields and measuring the resultant shifts in transition frequency.

preprint2020arXiv

Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks

Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.

preprint2020arXiv

Optical Atomic Clock Comparison through Turbulent Air

We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.

preprint2020arXiv

Quantum entanglement between an atom and a molecule

Conventional information processors freely convert information between different physical carriers to process, store, or transmit information. It seems plausible that quantum information will also be held by different physical carriers in applications such as tests of fundamental physics, quantum-enhanced sensors, and quantum information processing. Quantum-controlled molecules in particular could transduce quantum information across a wide range of quantum-bit (qubit) frequencies, from a few kHz for transitions within the same rotational manifold, a few GHz for hyperfine transitions, up to a few THz for rotational transitions, to hundreds of THz for fundamental and overtone vibrational and electronic transitions, possibly all within the same molecule. Here, we report the first demonstration of entanglement between states of the rotation of a $\rm^{40}CaH^+$ molecular ion and internal states of a $\rm^{40}Ca^+$ atomic ion. The qubit addressed in the molecule has a frequency of either 13.4 kHz or 855 GHz, highlighting the versatility of molecular qubits. This work demonstrates how molecules can transduce quantum information between qubits with different frequencies to enable hybrid quantum systems. We anticipate that quantum control and measurement of molecules as demonstrated here will create opportunities for quantum information science, quantum sensors, fundamental and applied physics, and controlled quantum chemistry.

preprint2016arXiv

Probing beyond the laser coherence time in optical clock comparisons

We develop differential measurement protocols that circumvent the laser noise limit in the stability of optical clock comparisons by synchronous probing of two clocks using phase-locked local oscillators. This allows for probe times longer than the laser coherence time, avoids the Dick effect, and supports Heisenberg-limited measurement precision. We present protocols for such frequency comparisons and develop numerical simulations of the protocols with realistic noise sources. These methods provide a route to reduce frequency ratio measurement durations by more than an order of magnitude.

preprint2015arXiv

An open source digital servo for AMO physics experiments

We describe a general purpose digital servo optimized for feedback control of lasers in atomic, molecular, and optical (AMO) physics experiments. The servo is capable of feedback bandwidths up to roughly 1~MHz (limited by the 320~ns total latency); loop filter shapes up to fifth order; multiple-input, multiple-output control; and automatic lock acquisition. The configuration of the servo is controlled via a graphical user interface, which also provides a rudimentary software oscilloscope and tools for measurement of system transfer functions. We illustrate the functionality of the digital servo by describing its use in two example scenarios: frequency control of the laser used to probe the narrow clock transition of $^{27}$Al$^+$ in an optical atomic clock, and length control of a cavity used for resonant frequency doubling of a laser.

preprint2015arXiv

Laser frequency stabilization based on steady-state spectral-hole burning in Eu$^{3+}$:Y$_2$SiO$_5$

We present and analyze a method of laser frequency stabilization via steady-state patterns of spectral holes in Eu$^{3+}$:Y$_2$SiO$_5$. Three regions of spectral holes are created, spaced in frequency by the ground state hyperfine splittings of $~^{151}$Eu$^{3+}$. The absorption pattern is shown not to degrade after days of laser frequency stabilization. An optical frequency comparison of a laser locked to such a steady-state spectral-hole pattern with an independent cavity-stabilized laser and a Yb optical lattice clock demonstrates a spectral-hole fractional frequency instability of $1.0\times10^{-15}~ τ^{-\frac{1}{2}}$ that averages to $8.5^{+4.8}_{-1.8}\times10^{-17}$ at $τ= 73$ s. Residual amplitude modulation at the frequency of the RF drive applied to the fiber-coupled electro-optic modulator is reduced to less than $1\times10^{-6}$ fractional amplitude modulation at $τ>$ 1 s by an active servo. The contribution of residual amplitude modulation to the laser frequency instability is further reduced by digital division of the transmission and incident photodetector signals to less than $1\times10^{-16}$ at $τ>$ 1 s.

preprint2013arXiv

Absolute and relative stability of an optical frequency reference based on spectral hole burning in Eu$^{3+}$:Y$_2$SiO$_5$

We present and analyze four frequency measurements designed to characterize the performance of an optical frequency reference based on spectral hole burning in \EuYSO. The first frequency comparison, between a single unperturbed spectral hole and a hydrogen maser, demonstrates a fractional frequency drift rate of $5 \times 10^{-18}$ s$^{-1}$. Optical-frequency comparisons between a pattern of spectral holes, a Fabry-Pérot cavity, and an Al$^+$ optical atomic clock show a short-term fractional frequency stability of $1 \times10^{-15} τ^{-1/2}$ that averages down to $2.5^{+1.1}_{-0.5} \times 10^{-16}$ at $τ= 540~s$ (with linear frequency drift removed). Finally, spectral hole patterns in two different \EuYSO crystals located in the same cryogenic vessel are compared, yielding a short-term stability of $7 \times10^{-16} τ^{-1/2}$ that averages down to $5.5^{+1.8}_{-0.9} \times 10^{-17}$ at $τ= 204$~s (with quadratic frequency drift removed).

preprint2013arXiv

Shifts of optical frequency references based on spectral-hole burning in Eu:Y2SiO5

Several properties of Eu:Y2SiO5 spectral holes are measured, to assess the suitability of broad-band hole-patterns for use as laser-frequency references. We measure frequency shifts due to magnetic fields, side-features of neighboring spectral holes, and changing optical probe power. A precise calibration of a temperature insensitive point is also performed, where the temperature-induced frequency shift is canceled to first order by the pressure-induced shift from the crystal's helium-gas environment.

preprint2012arXiv

A cavity-stabilized laser with acceleration sensitivity below $10^{-12}$/g

We characterize the frequency-sensitivity of a cavity-stabilized laser to inertial forces and temperature fluctuations, and perform real-time feed-forward to correct for these sources of noise. We measure the sensitivity of the cavity to linear accelerations, rotational accelerations, and rotational velocities by rotating it about three axes with accelerometers and gyroscopes positioned around the cavity. The worst-direction linear acceleration sensitivity of the cavity is $2(1) \times 10^{-11}$/g measured over 0-50 Hz, which is reduced by a factor of 50 to below $10^{-12}$/g for low-frequency accelerations by real-time feed-forward corrections of all of the aforementioned inertial forces. A similar idea is demonstrated in which laser frequency drift due to temperature fluctuations is reduced by a factor of 70 via real-time feed-forward from a temperature sensor located on the outer wall of the cavity vacuum chamber.

preprint2011arXiv

Field-test of a robust, portable, frequency-stable laser

We operate a frequency-stable laser in a non-laboratory environment where the test platform is a passenger vehicle. We measure the acceleration experienced by the laser and actively correct for it to achieve a system acceleration sensitivity of $Δf / f$ = $11(2) \times 10^{-12}$/g, $6(2) \times 10^{-12}$/g, and $4(1) \times 10^{-12}$/g for accelerations in three orthogonal directions at 1 Hz. The acceleration spectrum and laser performance are evaluated with the vehicle both stationary and moving. The laser linewidth in the stationary vehicle with engine idling is 1.7(1) Hz.

preprint2009arXiv

Cavity sideband cooling of a single trapped ion

We report a demonstration and quantitative characterization of one-dimensional cavity cooling of a single trapped 88Sr+ ion in the resolved sideband regime. We measure the spectrum of cavity transitions, the rates of cavity heating and cooling, and the steady-state cooling limit. The cavity cooling dynamics and cooling limit of 22.5(3) motional quanta, limited by the moderate coupling between the ion and the cavity, are consistent with a simple model [Phys. Rev. A 64, 033405] without any free parameters, validating the rate equation model for cavity cooling.

preprint2006arXiv

Electron impact ionization loading of a surface electrode ion trap

We demonstrate a method for loading surface electrode ion traps by electron impact ionization. The method relies on the property of surface electrode geometries that the trap depth can be increased at the cost of more micromotion. By introducing a buffer gas, we can counteract the rf heating assocated with the micromotion and benefit from the larger trap depth. After an initial loading of the trap, standard compensation techniques can be used to cancel the stray fields resulting from charged dielectric and allow for the loading of the trap at ultra-high vacuum.