Researcher profile

David M. Paganin

David M. Paganin contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

On optimization of Paganin's method for propagation-based X-ray phase-contrast imaging and tomography

Paganin's method for image reconstruction in propagation-based phase-contrast X-ray imaging and tomography has enjoyed broad acceptance in recent years, with over one thousand publications citing its use. The present paper discusses approaches to optimization of the method with respect to simple image quality metrics, such as signal-to-noise ratio and spatial resolution, as well as a reference-based metric corresponding to the relative mean squared difference between the reconstructed image and the "ground truth" image that would be obtained in a setup with perfect spatial resolution and no noise. The problem of optimization of the intrinsic regularization parameter of Paganin's method with respect to spatial resolution in the reconstructed image is studied in detail. It is also demonstrated that a combination of Paganin's method with a Tikhonov-regularized deconvolution of the point-spread function of the imaging system can provide significantly higher image quality compared to the standard version of the method. Analytical expressions for some relevant image quality metrics are obtained and compared with results of numerical simulations. Advantages and shortcomings of optimization approaches using a number of different image quality metrics are discussed. The results of this study are expected to be useful in practical X-ray imaging and training of deep machine learning models for image denoising and segmentation.

preprint2020arXiv

On the Inherent Dose-Reduction Potential of Classical Ghost Imaging

Classical ghost imaging is a computational imaging technique that employs patterned illumination. It is very similar in concept to the single-pixel camera in that an image may be reconstructed from a set of measurements even though all imaging quanta that pass through that sample are never recorded with a position resolving detector. The method was first conceived and applied for visible-wavelength photons and was subsequently translated to other probes such as x rays, atomic beams, electrons and neutrons. In the context of ghost imaging using penetrating probes that enable transmission measurement, we here consider several questions relating to the achievable signal-to-noise ratio (SNR). This is compared with the SNR for conventional imaging under scenarios of constant radiation dose and constant experiment time, considering both photon shot-noise and per-measurement electronic read-out noise. We show that inherent improved SNR capabilities of ghost imaging are limited to a subset of these scenarios and are actually due to increased dose (Fellgett advantage). An explanation is also presented for recent results published in the literature that are not consistent with these findings.

preprint2020arXiv

Single-shot x-ray speckle-based imaging of a single-material object

We develop a means for speckle-based phase imaging of the projected thickness of a single-material object, under the assumption of illumination by spatially random time-independent x-ray speckles. These speckles are generated by passing x rays through a suitable spatially random mask. The method makes use of a single image obtained in the presence of the object, which serves to deform the illuminating speckle field relative to a reference speckle field (which only needs to be measured once) obtained in the presence of the mask and the absence of the object. The method implicitly rather than explicitly tracks speckles, and utilizes the transport-of-intensity equation to give a closed-form solution to the inverse problem of determining the complex transmission function of the object. Implementation using x-ray synchrotron data shows the method to be robust and efficient with respect to noise. Applications include x-ray phase--amplitude radiography and tomography, as well as time-dependent imaging of dynamic and radiation-sensitive samples using low-flux sources.

preprint2019arXiv

Neutron Ghost Imaging

Ghost imaging is demonstrated using a poly-energetic reactor source of thermal neutrons. The method presented enables position resolution to be incorporated, into a variety of neutron instruments that are not position resolving. In an imaging context, ghost imaging can be beneficial for dose reduction and resolution enhancement. We also demonstrate a super-resolution variant of the method, namely a parallel form of neutron ghost imaging, with the ability to significantly increase the spatial resolution of a pixelated detector such as a CCD or CMOS camera. Extensions of our neutron ghost-imaging protocol are discussed in detail and include neutron ghost tomography, neutron ghost microscopy, dark-field neutron ghost imaging, and isotope-resolved color neutron ghost imaging via prompt gamma-ray bucket detection.