Source author record

D. L. Rubin

D. L. Rubin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

preprint2020arXiv

A limit on the anisotropy of the one-way maximum attainable speed of the electron

We report here the first experimental result for the anisotropy of the one-way maximum attainable speed of the electron, $\vec{Δc_{1,e}}$, obtained via the study of a sidereal time dependence of a difference between the electron and positron beam momenta in the CESR storage ring at Cornell University. At 95 percent confidence, an upper limit for the component of $Δ\vec {c}_{1,e}/c$ perpendicular to Earth's rotational axis is found to be $5.5 \times 10^{-15}$.

preprint2015arXiv

Operation of the CESR-TA vertical beam size monitor at $E_{\rm b}$=4 GeV

We describe operation of the CESR-TA vertical beam size monitor (xBSM) with $e^\pm$ beams with $E_{\rm b}$=4 GeV. The xBSM measures vertical beam size by imaging synchrotron radiation x-rays through an optical element onto a detector array of 32 InGaAs photodiodes with 50 $μ$m pitch. The device has previously been successfully used to measure vertical beam sizes of 10-100 $μ$m on a bunch-by-bunch, turn-by-turn basis at $e^\pm$ beam energies of $\sim$2 GeV and source magnetic fields below 2.8 kG, for which the detector required calibration for incident x-rays of 1-5 keV. At $E_{\rm b}=4.0$ GeV and $B$=4.5 kG, however, the incident synchrotron radiation spectrum extends to $\sim$20 keV, requiring calibration of detector response in that regime. Such a calibration is described and then used to analyze data taken with several different thicknesses of filters in front of the detector. We obtain a relative precision of better than 4% on beam size measurement from 15-100 $μ$m over several different ranges of x-ray energy, including both 1-12 keV and 6-17 keV. The response of an identical detector, but tilted vertically by 60$^\circ$ in order to increase magnfication without a longer beamline, is measured and shown to improve x-ray detection above 4 keV without compromising sensitivity to beam size. We also investigate operation of a coded aperture using gold masking backed by synthetic diamond.

preprint2014arXiv

Design and performance of coded aperture optical elements for the CESR-TA x-ray beam size monitor

We describe the design and performance of optical elements for an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2-5~$GeV. X-rays produced by a hard-bend magnet pass through a single- or multiple-slit (coded aperture) optical element onto a detector. The coded aperture slit pattern and thickness of masking material forming that pattern can both be tuned for optimal resolving power. We describe several such optical elements and show how well predictions of simple models track measured performances.

preprint2014arXiv

Vertical beam size measurement in the CESR-TA $e^+e^-$ storage ring using x-rays from synchrotron radiation

We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2~$GeV. At such beam energies the xBSM images x-rays of $ε\approx$1-10$~$keV ($λ\approx 0.1-1$ nm) that emerge from a hard-bend magnet through a single- or multiple-slit (coded aperture) optical element onto an array of 32 InGaAs photodiodes with 50$~μ$m pitch. Beamlines and detectors are entirely in-vacuum, enabling single-shot beam size measurement down to below 0.1$~$mA ($2.5\times10^9$ particles) per bunch and inter-bunch spacing of as little as 4$~$ns. At $E_{\rm b}=2.1 $GeV, systematic precision of $\sim 1~μ$m is achieved for a beam size of $\sim12~μ$m; this is expected to scale as $\propto 1/σ_{\rm b}$ and $\propto 1/E_{\rm b}$. Achieving this precision requires comprehensive alignment and calibration of the detector, optical elements, and x-ray beam. Data from the xBSM have been used to extract characteristics of beam oscillations on long and short timescales, and to make detailed studies of low-emittance tuning, intra-beam scattering, electron cloud effects, and multi-bunch instabilities.

preprint2014arXiv

Visible-light beam size monitors using synchrotron radiation at CESR

A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the horizontal and vertical beam sizes over a wide range of beam currents. By varying the separation of the slits, beam sizes ranging from 50 to 500 um can be measured with a resolution of approximately 5 um. To measure larger beam size (> 500 um), direct imaging can be employed by rotating the double slits away from SR beam path. By imaging the pi-polarized component of SR, a small vertical beam size (~70 um) was measured during an undulator test run in CESR, which was consistent with the interferometer measurement. To measure the bunch length, a beam splitter is inserted to direct a fraction of light into a streak camera setup. This beam size monitor measures the transverse and longitudinal beam sizes simultaneously, which is successfully used for intrabeam scattering studies. Detailed error analysis is discussed.