Source author record

A. Lyndaker

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
2topics
4close collaborators

Published work

3 publications

preprint2015arXiv

Operation of the CESR-TA vertical beam size monitor at EbE_{\rm b}=4 GeV

We describe operation of the CESR-TA vertical beam size monitor (xBSM) with e±e^\pm beams with EbE_{\rm b}=4 GeV. The xBSM measures vertical beam size by imaging synchrotron radiation x-rays through an optical element onto a detector array of 32 InGaAs photodiodes with 50 μμm pitch. The device has previously been successfully used to measure vertical beam sizes of 10-100 μμm on a bunch-by-bunch, turn-by-turn basis at e±e^\pm beam energies of ∼\sim2 GeV and source magnetic fields below 2.8 kG, for which the detector required calibration for incident x-rays of 1-5 keV. At Eb=4.0E_{\rm b}=4.0 GeV and BB=4.5 kG, however, the incident synchrotron radiation spectrum extends to ∼\sim20 keV, requiring calibration of detector response in that regime. Such a calibration is described and then used to analyze data taken with several different thicknesses of filters in front of the detector. We obtain a relative precision of better than 4% on beam size measurement from 15-100 μμm over several different ranges of x-ray energy, including both 1-12 keV and 6-17 keV. The response of an identical detector, but tilted vertically by 60∘^\circ in order to increase magnfication without a longer beamline, is measured and shown to improve x-ray detection above 4 keV without compromising sensitivity to beam size. We also investigate operation of a coded aperture using gold masking backed by synthetic diamond.

preprint2014arXiv

Design and performance of coded aperture optical elements for the CESR-TA x-ray beam size monitor

We describe the design and performance of optical elements for an x-ray beam size monitor (xBSM), a device measuring e+e^+ and e−e^- beam sizes in the CESR-TA storage ring. The device can measure vertical beam sizes of 10−100 μ10-100~μm on a turn-by-turn, bunch-by-bunch basis at e±e^\pm beam energies of ∼2−5 \sim2-5~GeV. X-rays produced by a hard-bend magnet pass through a single- or multiple-slit (coded aperture) optical element onto a detector. The coded aperture slit pattern and thickness of masking material forming that pattern can both be tuned for optimal resolving power. We describe several such optical elements and show how well predictions of simple models track measured performances.

preprint2014arXiv

Vertical beam size measurement in the CESR-TA e+e−e^+e^- storage ring using x-rays from synchrotron radiation

We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring e+e^+ and e−e^- beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of 10−100 μ10-100~μm on a turn-by-turn, bunch-by-bunch basis at e±e^\pm beam energies of ∼2 \sim2~GeV. At such beam energies the xBSM images x-rays of ε≈ε\approx1-10 ~keV (λ≈0.1−1λ\approx 0.1-1 nm) that emerge from a hard-bend magnet through a single- or multiple-slit (coded aperture) optical element onto an array of 32 InGaAs photodiodes with 50 μ~μm pitch. Beamlines and detectors are entirely in-vacuum, enabling single-shot beam size measurement down to below 0.1 ~mA (2.5×1092.5\times10^9 particles) per bunch and inter-bunch spacing of as little as 4 ~ns. At Eb=2.1E_{\rm b}=2.1 GeV, systematic precision of ∼1 μ\sim 1~μm is achieved for a beam size of ∼12 μ\sim12~μm; this is expected to scale as ∝1/σb\propto 1/σ_{\rm b} and ∝1/Eb\propto 1/E_{\rm b}. Achieving this precision requires comprehensive alignment and calibration of the detector, optical elements, and x-ray beam. Data from the xBSM have been used to extract characteristics of beam oscillations on long and short timescales, and to make detailed studies of low-emittance tuning, intra-beam scattering, electron cloud effects, and multi-bunch instabilities.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview