Source author record

D. Hover

D. Hover appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2016arXiv

Resonance fluorescence from an artificial atom in squeezed vacuum

We present an experimental realization of resonance fluorescence in squeezed vacuum. We strongly couple microwave-frequency squeezed light to a superconducting artificial atom and detect the resulting fluorescence with high resolution enabled by a broadband traveling-wave parametric amplifier. We investigate the fluorescence spectra in the weak and strong driving regimes, observing up to 3.1 dB of reduction of the fluorescence linewidth below the ordinary vacuum level and a dramatic dependence of the Mollow triplet spectrum on the relative phase of the driving and squeezed vacuum fields. Our results are in excellent agreement with predictions for spectra produced by a two-level atom in squeezed vacuum [Phys. Rev. Lett. \textbf{58}, 2539-2542 (1987)], demonstrating that resonance fluorescence offers a resource-efficient means to characterize squeezing in cryogenic environments.

preprint2016arXiv

The Flux Qubit Revisited to Enhance Coherence and Reproducibility

The scalable application of quantum information science will stand on reproducible and controllable high-coherence quantum bits (qubits). Here, we revisit the design and fabrication of the superconducting flux qubit, achieving a planar device with broad frequency tunability, strong anharmonicity, high reproducibility, and relaxation times in excess of $40\,μ$s at its flux-insensitive point. Qubit relaxation times $T_1$ across 22 qubits are consistently matched with a single model involving resonator loss, ohmic charge noise, and 1/f flux noise, a noise source previously considered primarily in the context of dephasing. We furthermore demonstrate that qubit dephasing at the flux-insensitive point is dominated by residual thermal photons in the readout resonator. The resulting photon shot noise is mitigated using a dynamical decoupling protocol, resulting in $T_2\approx 85\,μ$s, approximately the $2T_1$ limit. In addition to realizing an improved flux qubit, our results uniquely identify photon shot noise as limiting $T_2$ in contemporary qubits based on transverse qubit-resonator interaction.

preprint2015arXiv

Thermal and Residual Excited-State Population in a 3D Transmon Qubit

We present a systematic study of the first excited-state population in a 3D transmon qubit mounted in a dilution refrigerator with a variable temperature. Using a modified version of the protocol developed by Geerlings et al. [1], we observe the excited-state population to be consistent with a Maxwell-Boltzmann distribution, i.e., a qubit in thermal equilibrium with the refrigerator, over the temperature range 35-150 mK. Below 35 mK, the excited-state population saturates to 0.1%, near the resolution of our measurement. We verified this result using a flux qubit with ten-times stronger coupling to its readout resonator. We conclude that these qubits have effective temperature T_{eff} = 35 mK. Assuming T_{eff} is due solely to hot quasiparticles, the inferred qubit lifetime is 108 us and in plausible agreement with the measured 80 us.

preprint2014arXiv

High fidelity single-shot readout of a transmon qubit using a SLUG μwave amplifier

We report high-fidelity, quantum nondemolition, single-shot readout of a superconducting transmon qubit using a DC-biased superconducting low-inductance undulatory galvanometer(SLUG) amplifier. The SLUG improves the system signal-to-noise ratio by 7 dB in a 20 MHz window compared with a bare HEMT amplifier. An optimal cavity drive pulse is chosen using a genetic search algorithm, leading to a maximum combined readout and preparation fidelity of 91.9% with a measurement time of Tmeas = 200ns. Using post-selection to remove preparation errors caused by heating, we realize a combined preparation and readout fidelity of 94.3%.

preprint2013arXiv

High Fidelity Qubit Readout with the Superconducting Low-Inductance Undulatory Galvanometer Microwave Amplifier

We describe the high fidelity dispersive measurement of a superconducting qubit using a microwave amplifier based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). The SLUG preamplifier achieves gain of 19 dB and yields a signal-to-noise ratio improvement of 9 dB over a state-of-the-art HEMT amplifier. We demonstrate a separation fidelity of 99% at 700 ns compared to 59% with the HEMT alone. The SLUG displays a large dynamic range, with an input saturation power corresponding to 700 photons in the readout cavity.

preprint2012arXiv

Coherent Josephson phase qubit with a single crystal silicon capacitor

We have incorporated a single crystal silicon shunt capacitor into a Josephson phase qubit. The capacitor is derived from a commercial silicon-on-insulator wafer. Bosch reactive ion etching is used to create a suspended silicon membrane; subsequent metallization on both sides is used to form the capacitor. The superior dielectric loss of the crystalline silicon leads to a significant increase in qubit energy relaxation times. T1 times up to 1.6 micro-second were measured, more than a factor of two greater than those seen in amorphous phase qubits. The design is readily scalable to larger integrated circuits incorporating multiple qubits and resonators.

preprint2011arXiv

Microwave Photon Counter Based on Josephson Junctions

We describe a microwave photon counter based on the current-biased Josephson junction. The junction is tuned to absorb single microwave photons from the incident field, after which it tunnels into a classically observable voltage state. Using two such detectors, we have performed a microwave version of the Hanbury Brown and Twiss experiment at 4 GHz and demonstrated a clear signature of photon bunching for a thermal source. The design is readily scalable to tens of parallelized junctions, a configuration that would allow number-resolved counting of microwave photons.

preprint2011arXiv

SLUG Microwave Amplifier: Theory

We describe a novel scheme for low-noise phase-insensitive linear amplification at microwave frequencies based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). Direct integration of the junction equations of motion provides access to the full scattering matrix of the SLUG. We discuss the optimization of SLUG amplifiers and calculate amplifier gain and noise temperature in both the thermal and quantum regimes. Loading of the SLUG element by the finite input admittance is taken into account, and strategies for decoupling the SLUG from the higher-order modes of the input circuit are discussed. The microwave SLUG amplifier is expected to achieve noise performance approaching the standard quantum limit in the frequency range from 5-10 GHz, with gain around 15 dB for a single-stage device and instantaneous bandwidths of order 1 GHz.

preprint2011arXiv

Superconducting Low-Inductance Undulatory Galvanometer Microwave Amplifier

We describe a microwave amplifier based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). The SLUG is embedded in a microstrip resonator, and the signal current is injected directly into the device loop. Measurements at 30 mK show gains of 25 dB at 3 GHz and 15 dB at 9 GHz. Amplifier performance is well described by a simple numerical model based on the Josephson junction phase dynamics. We expect optimized devices based on high critical current junctions to achieve gain greater than 15 dB, bandwidth of several hundred MHz, and added noise of order one quantum in the frequency range of 5-10 GHz.