Researcher profile

Calum Williams

Calum Williams contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Optimizing achromaticity in metalenses, and development of a layered thin-film metalens

Metalenses are ultrathin optical devices designed to replicate behavior of conventional refractive lenses, or lens arrays, utilizing nanoscale resonant structures to redirect incident light. These are often comprised of discrete meta-atoms such as nanoscale dielectric pillars. Achromatic focusing - associated with traditional multi-element refractive counterparts - is frequently attempted with single-layer metalens designs, which has proven difficult to achieve with bounded refractive indices and total lens thickness. A recent study (F.Presutti and F.Monticone, 2020) formalized this, applying optical delay-line limitations to metalenses, resulting in a generalized trade-off in achromaticity for focusing systems. In this work, we (1) theoretically explore achromaticity in metalens design, and (2) propose a thin-film multilayer design as an alternative to the discrete meta-atom approach for large numerical aperture (NA) achromatic metalenses. It is shown that wavefront modulation can also be achieved with spectrally-varying transmission magnitudes, rather than purely matching a phase profile. In fact, even with a bounded refractive index, perfect achromatic operation over a given spectral range can be offset by imperfect operation elsewhere, resulting in a NA limited by the smallest general spectral feature controlled. These considerations lead to a generalized phase-matching optimization routine, and a thin-film metalens is simulated, utilizing layered TiO2/MgF2 with total thicknesses under 1 μm (20 layers), focusing across 6 simultaneous wavelengths (350-740 nm, Δλ~65 nm). A significant proportion (>40% spectral average) of the reflected light is focused for moderate NA (~0.35). With the maturity of the optical coating industry, the conformal thin-film approach reduces manufacturing complexity from its discrete nanoscale meta-atom equivalents.

preprint2021arXiv

Automated real-time spectral characterization of phase-change tunable optical filters using a linear variable filter and infrared camera

Actively tunable optical filters based on chalcogenide phase-change materials (PCMs) are an emerging technology with applications across chemical spectroscopy and thermal imaging. The refractive index of an embedded PCM thin film is modulated through an amorphous-to-crystalline phase transition induced through thermal stimulus. Performance metrics include transmittance, passband center wavelength (CWL), and bandwidth; ideally monitored during operation (in situ) or after a set number of tuning cycles to validate real-time operation. Measuring these aforementioned metrics in real-time is challenging. Fourier-transform infrared spectroscopy (FTIR) provides the gold-standard for performance characterization, yet is expensive and inflexible -- incorporating the PCM tuning mechanism is not straightforward, hence in situ electro-optical measurements are challenging. In this work, we implement an open-source MATLAB-controlled real-time performance characterization system consisting of an inexpensive linear variable filter (LVF) and mid-wave infrared camera, capable of switching the PCM-based filters while simultaneously recording in situ filter performance metrics and spectral filtering profile. These metrics are calculated through pixel intensity measurements and displayed on a custom-developed graphical user interface in real-time. The CWL is determined through spatial position of intensity maxima along the LVF's longitudinal axis. Furthermore, plans are detailed for a future experimental system that further reduces cost, is compact, and utilizes a near-infrared camera.

preprint2020arXiv

PCM-net: A refractive index database of chalcogenide phase change materials for tunable nanophotonic device modelling

Recently, chalcogenide glass based phase change materials (PCMs) have shown utility as a tuning material for a range of nanophotonic devices. Owing to their low loss, ultrafast switching speeds and wide waveband operation, PCMs are integrated in an increasing number of next generation tunable components, including integrated photonic switches, metasurface optics and tunable spectral filters. Nonetheless, modelling of PCM-based devices is challenging, both in terms of accurate representation of experimentally-derived material properties in different phase states, and standardization of results across the research community. In this work, we introduce PCMnet, an online database of the complex refractive indices of a variety of chalcogenide glass PCMs (such as GeSbTe), as an accessible and indexed repository for data sharing across the PCM community. Refractive indices (n) and extinction coefficients (k) between amorphous and crystalline states are directly extracted from experimentally-derived data in numerous academic research articles, and collated into the material resource database. Due to the inaccuracies associated with our data collection methods, this data is supplemented with additional computationally-generated data, obtained through WVASE, a commercial ellipsometry analysis software package. To demonstrate the utility of PCMnet, we provide a NASA application-driven device optimization example using the optical properties of PCMs collected with our database. We anticipate the database providing great use to the PCM community and coordinated research efforts enabled by PCMnet will promote the shared repository for the selection of appropriate PCMs for tunable nanophotonic device design for a range of applications.

preprint2020arXiv

Tunable mid-wave infrared Fabry-Perot bandpass filters using phase-change GeSbTe

We demonstrate spectrally-tunable Fabry-Perot bandpass filters operating across the MWIR by utilizing the phase-change material GeSbTe (GST) as a tunable cavity medium between two (Ge:Si) distributed Bragg reflectors. The induced refractive index modulation of GST increases the cavity's optical path length, red-shifting the passband. Our filters have spectral-tunability of ~300 nm, transmission efficiencies of 60-75% and narrowband FWHMs of 50-65 nm (Q-factor ~70-90). We further show multispectral thermal imaging and gas sensing. By matching the filter's initial passband to a CO$_{2}$ vibrational-absorption mode (~4.25 $μ$m), tunable atmospheric CO$_{2}$ sensing and dynamic plume visualization of added CO$_{2}$ is realized.

preprint2019arXiv

All-optical continuous tuning of phase-change plasmonic metasurfaces for multispectral thermal imaging

Actively tunable, narrowband spectral filtering across arbitrary optical wavebands is highly desirable in a plethora of applications, from chemical sensing, hyperspectral imaging to infrared astronomy. Yet, the ability to actively reconfigure the optical properties of a solid-state narrowband filter remains elusive. Existing solutions require either moving parts, have slow response times or provide limited spectral coverage. Here, we demonstrate a continuously tunable, spectrally-agnostic, all-solid-state, narrowband phase-change metasurface filter based on a GeSbTe (GST)-embedded plasmonic nanohole array. The passband of the presented tunable filter is ~74 nm with ~70% transmittance and operates across 3 - 5 $μ$m; the thermal imaging waveband. Continuous, reconfigurable tuning is achieved by exploiting intermediate GST phases via optical switching with a single nanosecond laser pulse and material stability is verified through multiple switching cycles. We further demonstrate multispectral thermal imaging in the mid-wave infrared using our phase-change metasurfaces. Our results pave the way for highly functional, reduced power, compact hyperspectral imaging systems and optical filters.

preprint2019arXiv

Grayscale-to-color: Single-step fabrication of bespoke multispectral filter arrays

Conventional cameras, such as in smartphones, capture wideband red, green and blue (RGB) spectral components, replicating human vision. Multispectral imaging (MSI) captures spatial and spectral information beyond our vision but typically requires bulky optical components and is expensive. Snapshot multispectral image sensors have been proposed as a key enabler for a plethora of MSI applications, from diagnostic medical imaging to remote sensing. To achieve low-cost and compact designs, spatially variant multispectral filter arrays (MSFAs) based on thin-film optical components are deposited atop image sensors. Conventional MSFAs achieve spectral filtering through either multi-layer stacks or pigment, requiring: complex mixtures of materials; additional lithographic steps for each additional wavelength; and large thicknesses to achieve high transmission efficiency. By contrast, we show here for the first time a single-step grayscale lithographic process that enables fabrication of bespoke MSFAs based on the Fabry-Perot resonances of spatially variant metal-insulator-metal (MIM) cavities, where the exposure dose controls insulator (cavity) thickness. We demonstrate customizable MSFAs scalable up to N-wavelength bands spanning the visible and near-infrared with high transmission efficiency (~75%) and narrow linewidths (~50 nm). Using this technique, we achieve multispectral imaging of several spectrally distinct target using our bespoke MIM-MSFAs fitted to a monochrome CMOS image sensor. Our unique framework provides an attractive alternative to conventional MSFA manufacture, by reducing both fabrication complexity and cost of these intricate optical devices, while increasing customizability.

preprint2018arXiv

Quantitative phase and polarisation endoscopy applied to detection of early oesophageal tumourigenesis

Phase and polarisation of coherent light are highly perturbed by interaction with microstructural changes in pre-malignant tissue, holding promise for label-free early cancer detection in endoscopically accessible tissues such as the gastrointestinal tract. Flexible optical fibres used in conventional diagnostic endoscopy scramble phase and polarisation, restricting clinicians instead to low-contrast amplitude-only imaging. Here, we unscramble phase and polarisation images by exploiting the near-diagonal multi-core fibre (MCF) transmission matrix to create a novel parallelised fibre characterisation architecture, scalable to arbitrary MCFs without additional experimental overhead. Our flexible MCF holographic endoscope produces full-field en-face images of amplitude, quantitative phase and resolved polarimetric properties using a low-cost laser diode and camera. We demonstrate that recovered phase enables computational re-focusing at working distances up to 1mm over a field-of-view up to 750$\times$750 $μm^2$. Furthermore, we demonstrate that the spatial distribution of phase and polarisation information enables label-free visualisation of early tumours in oesophageal mouse issue that are not identifiable using conventional amplitude-only information, a milestone towards future application for early cancer detection in endoscopy.