Researcher profile

C. Arnaboldi

C. Arnaboldi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2012arXiv

Double-beta decay of $^{130}$Te to the first 0$^{+}$ excited state of $^{130}$Xe with CUORICINO

The CUORICINO experiment was an array of 62 TeO$_{2}$ single-crystal bolometers with a total $^{130}$Te mass of $11.3\,$kg. The experiment finished in 2008 after more than 3 years of active operating time. Searches for both $0ν$ and $2ν$ double-beta decay to the first excited $0^{+}$ state in $^{130}$Xe were performed by studying different coincidence scenarios. The analysis was based on data representing a total exposure of N($^{130}$Te)$\cdot$t=$9.5\times10^{25}\,$y. No evidence for a signal was found. The resulting lower limits on the half lives are $T^{2ν}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>1.3\times10^{23}\,$y (90% C.L.), and $T^{0ν}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>9.4\times10^{23}\,$y (90% C.L.).

preprint2011arXiv

A novel technique of particle identification with bolometric detectors

We report in this paper the proofs that the pulse shape analysis can be used in some bolometers to identify the nature of the interacting particle. Indeed, while detailed analyses of the signal time development in purely thermal detectors have not produced so far interesting results, similar analyses on bolometers built with scintillating crystals seem to show that it is possible to distinguish between an electron or gamma-ray and an alpha particle interaction. This information can be used to eliminate background events from the recorded data in many rare process studies, especially Neutrinoless Double Beta decay search. Results of pulse shape analysis of signals from a number of bolometers with absorbers of different composition (CaMoO4, ZnMoO4, MgMoO4 and ZnSe) are presented and the pulse shape discrimination capability of such detectors is discussed.

preprint2011arXiv

CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background

The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been obtained for bulk contaminations and surface contaminations from several nuclides. An extrapolation to the CUORE background has been performed.

preprint2011arXiv

Search for beta plus/EC double beta decay of 120Te

We present a search for beta plus/EC double beta decay of 120Te performed with the CUORICINO experiment, an array of TeO2 cryogenic bolometers. After collecting 0.0573 kg y of 120Te, we see no evidence of a signal and therefore set the following limits on the half-life: T1/2 (0nu) > 1.9 10^{21} y at 90% C.L. for the 0 neutrino mode and T1/2 (2nu) > 7.6 10^{19} y at 90% C.L. for the two neutrino mode. These results improve the existing limits by almost three orders of magnitude (four in the case of 0 neutrino mode).

preprint2010arXiv

130Te Neutrinoless Double-Beta Decay with CUORICINO

We report the final result of the CUORICINO experiment. Operated between 2003 and 2008, with a total exposure of 19.75 kg y of 130Te, CUORICINO was able to set a lower bound on the 130Te 0nDBD half-life of 2.8 10^{24} years at 90% C.L. The limit here reported includes the effects of systematic uncertainties that are examined in detail in the paper. The corresponding upper bound on the neutrino Majorana mass is in the range 300--710 meV, depending on the adopted nuclear matrix element evaluation.

preprint2010arXiv

CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors

We report the performances of a 0.51 kg CdWO4 scintillating bolometer to be used for future Double Beta Decay Experiments. The simultaneous read-out of the heat and the scintillation light allows to discriminate between different interacting particles aiming at the disentanglement and the reduction of background contribution, key issue for next generation experiments. We will describe the observed anticorrelation between the heat and the light signal and we will show how this feature can be used in order to increase the energy resolution of the bolometer over the entire energy spectrum, improving up to a factor 2.6 on the 2615 keV line of 208Tl. The detector was tested in a 433 h background measurement that permitted to estimate extremely low internal trace contaminations of 232Th and 238U. The light yield of gamma/beta, alpha and neutrons is presented. Furthermore we developed a method in order to correctly evaluate the absolute thermal quenching factor of alpha particles in scintillating bolometers.

preprint2010arXiv

Characterization of ZnSe scintillating bolometers for Double Beta Decay

ZnSe scintillating bolometers are good candidates for future Double Beta Decay searches, because of the 82Se high Q-value and thanks to the possibility of alpha background rejection on the basis of the scintillation signal. In this paper we report the characteristics and the anomalies observed in an extensive study of these devices. Among them, an unexpected high emission from alpha particles, accompanied with an unusual pattern of the light vs. heat scatter plot. The perspectives for the application of this kind of detectors to search for the Neutrinoless Double Beta Decay of 82Se are presented.

preprint2010arXiv

Muon-induced backgrounds in the CUORICINO experiment

To better understand the contribution of cosmic ray muons to the CUORICINO background, 10 plastic scintillator detectors were installed at the CUORICINO site and operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV kg yr) (95% CL) was obtained on the cosmic ray-induced background in the neutrinoless double beta decay region of interest. The measurements were also compared to Geant4 simulations.

preprint2010arXiv

Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.

preprint2010arXiv

Production of high purity TeO2 single crystals for the study of neutrinoless double beta decay

High purity TeO2 crystals are produced to be used for the search for the neutrinoless double beta decay of 130Te. Dedicated production lines for raw material synthesis, crystal growth and surface processing were built compliant with radio-purity constraints specific to rare event physics experiments. High sensitivity measurements of radio-isotope concentrations in raw materials, reactants, consumables, ancillaries and intermediary products used for TeO2 crystals production are reported. Production and certification protocols are presented and resulting ready-to-use TeO2 crystals are described.

preprint2005arXiv

The Microcalorimeter Arrays for a Rhenium Experiment (MARE): a next-generation calorimetric neutrino mass experiment

Neutrino oscillation experiments have proved that neutrinos are massive particles, but can&#39;t determine their absolute mass scale. Therefore the neutrino mass is still an open question in elementary particle physics. An international collaboration is growing around the project of Microcalorimeter Arrays for a Rhenium Experiment (MARE) for directly measuring the neutrino mass with a sensitivity of about 0.2eV/c2. Many groups are joining their experiences and technical expertise in a common effort towards this challenging experiment. We discuss the different scenarios and the impact of MARE as a complement of KATRIN.

preprint2002arXiv

CUORE: A Cryogenic Underground Observatory for Rare Events

CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.