Researcher profile

Ingo Ernsting

Ingo Ernsting contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
6works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2015arXiv

A quantum cascade laser-based mid-IR frequency metrology system with ultra-narrow linewidth and $1\times 10^{-13}$-level frequency instability

We demonstrate a powerful tool for high-resolution mid-IR spectroscopy and frequency metrology with quantum cascade lasers (QCLs). We have implemented frequency stabilization of a QCL to an ultra-low expansion (ULE) reference cavity, via upconversion to the near-IR spectral range, at a level of $1\times10^{-13}$. The absolute frequency of the QCL is measured relative to a hydrogen maser, with instability $<1\times10^{-13}$ and inaccuracy $5\times10^{-13}$, using a frequency comb phase-stabilized to an independent ultrastable laser. The QCL linewidth is determined to be 60 Hz, dominated by fiber noise. Active suppression of fiber noise could result in sub-10 Hz linewidth.

preprint2014arXiv

A silicon single-crystal cryogenic optical resonator

We report on the demonstration and characterization of a silicon optical resonator for laser frequency stabilization, operating in the deep cryogenic regime at temperatures as low as 1.5 K. Robust operation was achieved, with absolute frequency drift less than 20 Hz over 1 hour. This stability allowed sensitive measurements of the resonator thermal expansion coefficient ($α$). We found $α=4.6\times10^{-13}$ ${\rm K^{-1}}$ at 1.6 K. At 16.8 K $α$ vanishes, with a derivative equal to $-6\times10^{-10}$ ${\rm K}^{-2}$. The temperature of the resonator was stabilized to a level below 10 $μ$K for averaging times longer than 20 s. The sensitivity of the resonator frequency to a variation of the laser power was also studied. The corresponding sensitivities and the expected Brownian noise indicate that this system should enable frequency stabilization of lasers at the low-$10^{-17}$ level.

preprint2013arXiv

Robust frequency stabilization of multiple spectroscopy lasers with large and tunable offset frequencies

We demonstrate a compact and robust device for simultaneous absolute frequency stabilization of three diode lasers whose carrier frequencies can be chosen freely relative to the reference. A rigid ULE multi-cavity block is employed, and, for each laser, the sideband locking technique is applied. Useful features of the system are a negligible lock error, computer control of frequency offset, wide range of frequency offset, simple construction, and robust operation. One concrete application is as a stabilization unit for the cooling and trapping lasers of a neutral atom lattice clock. The device significantly supports and improves the operation of the clock. The laser with the most stringent requirements imposed by this application is stabilized to a linewidth of 70 Hz, and a residual frequency drift less than 0.5 Hz/s. The carrier optical frequency can be tuned over 350 MHz while in lock.

preprint2013arXiv

Robust, frequency-stable and accurate mid-IR laser spectrometer based on frequency comb metrology of quantum cascade lasers up-converted in orientation-patterned GaAs

We demonstrate a robust and simple method for measurement, stabilization and tuning of the frequency of cw mid-infrared (MIR) lasers, in particular of quantum cascade lasers. The proof of principle is performed with a quantum cascade laser at 5.4 μm, which is upconverted to 1.2 μm by sum-frequency generation in orientation-patterned GaAs with the output of a standard high-power cw 1.5 μm fiber laser. Both the 1.2 μm and the 1.5 μm waves are measured by a standard Er:fiber frequency comb. Frequency measurement at the 100 kHz-level, stabilization to sub-10 kHz level, controlled frequency tuning and long-term stability are demonstrated.

preprint2011arXiv

Demonstration of a Transportable 1 Hz-Linewidth Laser

We present the setup and test of a transportable clock laser at 698 nm for a strontium lattice clock. A master-slave diode laser system is stabilized to a rigidly mounted optical reference cavity. The setup was transported by truck over 400 km from Braunschweig to Düsseldorf, where the cavity-stabilized laser was compared to a stationary clock laser for the interrogation of ytterbium (578 nm). Only minor realignments were necessary after the transport. The lasers were compared by a Ti:Sapphire frequency comb used as a transfer oscillator. The thus generated virtual beat showed a combined linewidth below 1 Hz (at 1156 nm). The transport back to Braunschweig did not degrade the laser performance, as was shown by interrogating the strontium clock transition.

preprint2011arXiv

Spectrally narrow, long-term stable optical frequency reference based on a Eu$^{3+}$:Y$_{2}$SiO$_{5}$ crystal at cryogenic temperature

Using an ultrastable continuous-wave laser at 580 nm we performed spectral hole burning of Eu$^{3+}$:Y$_{2}$SiO$_{5}$ at very high spectral resolution. Essential parameters determining the usefulness as a &#34;macroscopic&#34; frequency reference: linewidth, temperature sensitivity, long-term stability were characterized, using a H-maser stabilized frequency comb. Spectral holes with linewidth as low as 6 kHz were observed and the upper limit of the drift of the hole frequency was determined to be on the order of 5$\pm$3 mHz/s. We discuss necessary requirements for achieving ultra-high-stability in laser frequency stabilization to these spectral holes.