Source author record

A. M. Gezhaev

A. M. Gezhaev appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

$^{222}$Rn content variations at ground and underground conditions

The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of the cylindrical ionionization air chamber. We found that the radon content in the ventilated airflow within the measurement accuracy does not depend on the distance travelled along the adit. In addition, we observed that the radon content increases abruptly in those locations where underground gases and water are released. As a result, we review various mechanisms of air enrichment with radon. We also outline our research methodology and present the results of our measurements of radon release from the rocky walls of the underground laboratory. Finally, we present the results of the measurements of the radon content of various ground and underground water sources.

preprint2020arXiv

Annual variations of the $^{214}$Po, $^{213}$Po and $^{212}$Po half-life values

Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal functions. The sinusoid curve with amplitude $A=(5.0 \pm1.5) \cdot 10^{-4}$, period $ω=(365\pm 8)$ days, and phase $ϕ=(170 \pm 7)$ days approximates the set of $^{214}$Po $τ$ values obtained at BNO INR RAS during the $\sim$973 days starting on January 4, 2012. The function approximates a set of $τ$-values with a time duration of $\sim1460$ days obtained at the KhNU has an amplitude $A=(4.9\pm1.8)\cdot10^{-4}$, a period $ω= (377\pm13)$ days and a phase $ϕ=(77\pm10)$ days. The $^{213}$Po $τ$-value set with a time duration of $\sim1700$ days can be described by a sinusoidal function with an amplitude $A=(3.9\pm1.2)\cdot10^{-4}$, a period $ω= (370\pm13)$ days and a phase $ϕ=(130\pm9)$ days. The $^{212}$Po $τ$-value set with a time duration of $\sim670$ days can be described by a sinusoidal function with an amplitude $A=(7.5\pm1.6)\cdot10^{-4}$, a period $ω= (375\pm13)$ days and a phase $ϕ=(40\pm10)$ days.

preprint2015arXiv

Characteristics of a thermal neutrons scintillation detector with the [ZnS(Ag)+$^6$LiF] at different conditions of measurements

A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performed. The results are compared with the ones measured by the $^3$He proportional counter.

preprint2015arXiv

High-resolution ion pulse ionization chamber with air filling for the Rn-222 decays detection

The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register alpha-particles from the $^{222}$Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV alpha-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented.

preprint2015arXiv

Results of measurements of an environment neutron background at BNO INR RAS objects with the helium proportional counter

A method of measurements of the environmental neutron background at the Baksan Neutrino Observatory of the INR RAS are described. Measurements were done by using of a proportional counter filled with mixture of Ar(2 at)+$^3$He(4 at). The results obtained at the surface and the underground laboratory of the BNO INR RAS are presented. It is shown that a neutron background in the underground laboratory at the 4900 m w.e. depth is decreased by $\sim 260$ times without any special shield in a comparison with the Earth surface. A neutron flux density in the 5-1323.5~cm air height region is constant within the determination error and equal to $(7.1\pm0.1_{\rm{stat}}\pm0.3_{\rm{syst}})\times10^{-3}$ s$^{-1}\cdot$cm$^{-2}$.

preprint2015arXiv

Technical Design Report for the AMoRE $0νββ$ Decay Search Experiment

The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \mohundred nuclide was chosen for this \zeronubb decay search because of its high $Q$-value and favorable nuclear matrix element. Tests have demonstrated that \camo crystals produce the brightest scintillation light among all of the molybdate crystals, both at room and at cryogenic temperatures. $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals are being operated at milli-Kelvin temperatures and read out via specially developed metallic-magnetic-calorimeter (MMC) temperature sensors that have excellent energy resolution and relatively fast response times. The excellent energy resolution provides good discrimination of signal from backgrounds, and the fast response time is important for minimizing the irreducible background caused by random coincidence of two-neutrino double-beta decay events of \mohundred nuclei. Comparisons of the scintillating-light and phonon yields and pulse shape discrimination of the phonon signals will be used to provide redundant rejection of alpha-ray-induced backgrounds. An effective Majorana neutrino mass sensitivity that reaches the expected range of the inverted neutrino mass hierarchy, i.e., 20-50 meV, could be achieved with a 200~kg array of $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals operating for three years.

preprint2015arXiv

The study of the thermal neutron flux in the deep underground laboratory DULB-4900

We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the absolute humidity of the air in laboratory. The amplitude of the modulation exceed 5\% of total neutron flux.

preprint2012arXiv

Working characteristics of the New Low-Background Laboratory (DULB-4900, Baksan Neutrino Observatory)

A concise technical characteristic of a new low-background laboratory DULB-4900 of the BNO INR RAS is presented. The technique and the results of background measurements in the Hall, ordinary box and low-background box are presented. Rn-222 contamination in the laboratory air has been measured by direct detection of gamma-radiation of its daughter Bi-214 distributed over the volume of the low-background box. The results of the data analysis are presented.

preprint2011arXiv

Experimental test of the time stability of the half-life of alpha-decay Po-214 nuclei

A method and results of an experimental test of the time stability of the half-life of alpha-decay Po-214 nuclei are presented. Two underground installations aimed at monitoring the time stability have been constructed. Time of measurement exceeds 1038 days for one set up and 562 days for the other. It was found that amplitude of possible annual variation of Po-214 half-life does not exceed 0.2% of the mean value. The limit on the deviation of the decay curve from exponent at 0.034\times T_{1/2}<t< 0.1\times T_{1/2} range has been found.