Abstract
High-purity germanium crystals approximately 12 cm in diameter were grown in a hydrogen atmosphere using the Czochralski method. The dislocation density of the crystals was determined to be in the range of 2000 - 4200 cm-2, which meets a requirement for use as a radiation detector. The axial and radial distributions of impurities in the crystals were measured and are discussed. A planar detector was also fabricated from one of the crystals and then evaluated for electrical and spectral performance. Measurements of gamma-ray spectra from Cs-137 and Am-241 sources demonstrate that the detector has excellent energy resolution.