Abstract
Dual-comb microscopy (DCM), an interesting imaging modality based on the optical-frequency-comb (OFC) mode and image pixel one-to-one correspondence, benefits from scan-less full-field imaging and simultaneous confocal amplitude and phase imaging. However, the two fully frequency-stabilized OFC sources requirement hampers DCM practicality due to the complexity and costs. Here, a bidirectional single-cavity dual-comb fiber laser (SCDCFL) is adopted as a DCM low-complexity OFC source. Computational image correction reduces the image blur caused by the SCDCFL residual timing jitter. Nanometer-order step surface profilometry with a 14.0 nm uncertainty highlights the image-corrected DCM effectiveness. The proposed method enhances the DCM versality and practicality.