We are developing monolithic pixel sensors based on a 0.2 μμm fully-depleted Silicon-on-Insulator (SOI) technology for HEP experiment applications. The total ionizing dose (TID) effect is the major issue in the applications for hard radiation environments in HEP experiments. To compensate for TID damage, we have introduced a Double SOI structure which has a Middle Silicon layer (SOI2 layer) in addition. We studied the recovery from TID damage induced by 60Co γ\mathrm{^{60}Co}~γ's and other characteristics of an Integration-type Double SOI sensor. The Double SOI sensor irradiated to 100 kGy showed a response for IR laser similar to of a non-irradiated sensor when we applied a negative voltage to the SOI2 layer. We conclude that the Double SOI sensor is radiation hard enough to be used in HEP experiments in harsh radiation environments such as at Bell II or ILC.