Researcher profile

Zhili Wang

Zhili Wang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2015arXiv

Performance Analysis of Quantitative Phase Retrieval Method in Zernike Phase Contrast X-ray Microscopy

Since the invention of Zernike phase contrast method in 1930, it has been widely used in optical microscopy and more recently in X-ray microscopy. Considering the image contrast is a mixture of absorption and phase information, we recently have proposed and demonstrated a method for quantitative phase retrieval in Zernike phase contrast X-ray microscopy. In this contribution, we analyzed the performance of this method at different photon energies. Intensity images of PMMA samples are simulated at 2.5 keV and 6.2 keV, respectively, and phase retrieval is performed using the proposed method. The results demonstrated that the proposed phase retrieval method is applicable over a wide energy range. For weakly absorbing features, the optimal photon energy is 2.5 keV, from the point of view of image contrast and accuracy of phase retrieval. On the other hand, in the case of strong absorption objects, a higher photon energy is preferred to reduce the error of phase retrieval. Those results can be used as guidelines to perform quantitative phase retrieval in Zernike phase contrast X-ray microscopy with the proposed method.

preprint2015arXiv

Research on the background correction method in x-ray phase contrast imaging with Talbot-Lau interferometer

X-ray Talbot-Lau interferometer has been used widely to conduct phase contrast imaging with a conventional low-brilliance x-ray source. Typically, in this technique, background correction has to be performed in order to obtain the pure signal of the sample under inspection. In this study, we reported on a research on the background correction strategies within this technique, especially we introduced a new phase unwrapping solution for one conventional background correction method, the key point of this new solution is changing the initial phase of each pixel by a cyclic shift operation on the raw images collected in phase stepping scan. Experimental result and numerical analysis showed that the new phase unwrapping algorithm could successfully subtract contribution of the system's background without error. Moreover, a potential advantage of this phase unwrapping strategy is that its effective phase measuring range could be tuned flexibly in some degree for example to be (-pi+3, pi+3], thus it would find usage in certain case because measuring range of the currently widely used background correction method is fixed to be (-pi, pi].

preprint2014arXiv

A LabVIEW based user-friendly X-ray phase-contrast imaging system software platform

X-ray phase-contrast imaging can provide greatly improved contrast over conventional absorption-based imaging for weakly absorbing samples, such as biological soft tissues and fibre composites. In this manuscript, we introduce an easy and fast way to develop a user-friendly software platform dedicated to the new grating-based X-ray phase-contrast imaging setup recently built at the National Synchrotron Radiation Laboratory of the University of Science and Technology of China. Unified management and control of 21 motorized positioning stages, of an ultra-precision piezoelectric translation stage and of the X-ray tube are achieved with this platform. The software package also covers the automatic image acquisition of the phase-stepping scanning with a flat panel detector. Moreover, a data post-processing module for signals retrieval and other custom features are in principle available. With a seamless integration of all necessary functions in a unique package, this software platform will greatly support the user activity during experimental runs.

preprint2014arXiv

A user-friendly nano-CT image alignment and 3D reconstruction platform based on LabVIEW

X-ray computed tomography at the nanometer scale (nano-CT) offers a wide range of applications in scientific and industrial areas. Here we describe a reliable, user-friendly and fast software package based on LabVIEW that may allow to perform all procedures after the acquisition of raw projection images in order to obtain the inner structure of the investigated sample. A suitable image alignment process to address misalignment problems among image series due to mechanical manufacturing errors, thermal expansion and other external factors has been considered together with a novel fast parallel beam 3D reconstruction procedure, developed ad hoc to perform the tomographic reconstruction. Remarkably improved reconstruction results obtained at the Beijing Synchrotron Radiation Facility after the image calibration confirmed the fundamental role of this image alignment procedure that minimizes unwanted blurs and additional streaking artifacts always present in reconstructed slices. Moreover, this nano-CT image alignment and its associated 3D reconstruction procedure fully based on LabVIEW routines, significantly reduce the data post-processing cycle, thus making faster and easier the activity of the users during experimental runs.

preprint2014arXiv

Experimental research on the feature of an X-ray Talbot-Lau interferometer vs. tube accelerating voltage

X-ray Talbot-Lau interferometer has been used most widely to perform X-ray phase-contrast imaging with a conventional low-brilliance X-ray source, it yields high-sensitivity phase and dark-field images of sample producing low absorption contrast, thus bearing tremendous potential for future clinical diagnosis. In this manuscript, while changing accelerating voltage of the X-ray tube from 35KV to 45KV, X-ray phase-contrast imaging of a test sample were performed at each integer KV position to investigate the characteristic of an X-ray Talbot-Lau interferometer (located in the Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Japan) vs. tube voltage. Experimental results and data analysis show that this X-ray Talbot-Lau interferometer is insensitive to the tube accelerating voltage within a certain range, fringe visibility around 44% is maintained in the aforementioned tube voltage range. This experimental research implies that potential new dual energy phase-contrast X-ray imaging strategy and rough refraction spectrum measurement is feasible with this X-ray Talbot-Lau interferometer.