Source author record

Zheng Feng

Zheng Feng appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Variational Temporal Deconfounder for Individualized Treatment Effect Estimation from Longitudinal Observational Data

Estimating treatment effects, especially individualized treatment effects (ITE), using observational data is challenging due to the complex situations of confounding bias. Existing approaches for estimating treatment effects from longitudinal observational data are usually built upon a strong assumption of "unconfoundedness", which is hard to fulfill in real-world practice. In this paper, we propose the Variational Temporal Deconfounder (VTD), an approach that leverages deep variational embeddings in the longitudinal setting using proxies (i.e., surrogate variables that serve for unobservable variables). Specifically, VTD leverages observed proxies to learn a hidden embedding that reflects the true hidden confounders in the observational data. As such, our VTD method does not rely on the "unconfoundedness" assumption. We test our VTD method on both synthetic and real-world clinical data, and the results show that our approach is effective when hidden confounding is the leading bias compared to other existing models.

preprint2020arXiv

Ghost spintronic THz-emitter-array microscope

Terahertz (THz) wave shows great potential in non-destructive testing, bio detection and cancer imaging. Recent progresses on THz wave near-field probes/apertures enable mechanically raster scanning of an object's surface in the near-field region, while an efficient, non-scanning, non-invasive, deeply sub-diffraction-limited imaging still remains challenging. Here, we demonstrate a THz near-field microscopy using a reconfigurable spintronic THz emitter array (STEA) with computational ghost imaging. By illuminating an object with the reconfigurable STEA in near field and computing the correlation measurements, we reconstruct its image with deeply sub-diffraction resolution. By circulating an external magnetic field, the in-line polarization rotation of THz waves is realized, making the fused image contrast polarization-free. The time-of-flight (TOF) measurements of coherent THz pulses further enables to resolve objects at different distances or depths. The demonstrated ghost spintronic THz-emitter-array microscope (GHOSTEAM) is a new imaging tool for THz near-field real-time imaging (with potential of video framerate), especially opening up paradigm-shift opportunities in non-intrusive label-free bioimaging in a broadband frequency range from 0.1 THz to 30 THz (namely 3.3-1000 cm-1).

preprint2018arXiv

Comparing Clinical Judgment with MySurgeryRisk Algorithm for Preoperative Risk Assessment: A Pilot Study

Background: Major postoperative complications are associated with increased short and long-term mortality, increased healthcare cost, and adverse long-term consequences. The large amount of data contained in the electronic health record (EHR) creates barriers for physicians to recognize patients most at risk. We hypothesize, if presented in an optimal format, information from data-driven predictive risk algorithms for postoperative complications can improve physician risk assessment. Methods: Prospective, non-randomized, interventional pilot study of twenty perioperative physicians at a quarterly academic medical center. Using 150 clinical cases we compared physicians' risk assessment before and after interaction with MySurgeryRisk, a validated machine-learning algorithm predicting preoperative risk for six major postoperative complications using EHR data. Results: The area under the curve (AUC) of MySurgeryRisk algorithm ranged between 0.73 and 0.85 and was significantly higher than physicians' risk assessments (AUC between 0.47 and 0.69) for all postoperative complications except cardiovascular complications. The AUC for repeated physician's risk assessment improved by 2% to 5% for all complications with the exception of thirty-day mortality. Physicians' risk assessment for acute kidney injury and intensive care unit admission longer than 48 hours significantly improved after knowledge exchange, resulting in net reclassification improvement of 12.4% and 16%, respectively. Conclusions: The validated MySurgeryRisk algorithm predicted postoperative complications with equal or higher accuracy than pilot cohort of physicians using available clinical preoperative data. The interaction with algorithm significantly improved physicians' risk assessment.