Source author record

Zhao Wu

Zhao Wu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Heating at the remote footpoints as a brake on jet flows along loops in the solar atmosphere

We report on observations of a solar jet propagating along coronal loops taken by the Solar Dynamics Observatory (SDO), the Interface Region Imaging Spectragraph (IRIS) and 1-m New Vacuum Solar Telescope (NVST). The ejecta of the jet consist of multi-thermal components and propagate with a speed greater than 100 km/s. Brightenings are found in the remote footpoints of the coronal loops having compact and round-shape in the Halpha images. The emission peak of the remote brightening in the Atmospheric Imaging Assembly (AIA) 94 Ã…passband lags 60 s behind that in the jet base. The brightenings in the remote footpoints are believed to be consequences of heating by nonthermal electrons, MHD waves and/or conduction front generated by the magnetic reconnection processes of the jet. The heating in the remote footpoints leads to extension of the brightening along the loops toward the jet base, which is believed to be the chromospheric evaporation. This apparently acts as a brake on the ejecta, leading to a deceleration in the range from 1.5 to 3 km s$^{-2}$ with an error of $\sim1.0$\,km s$^{-2}$ when the chromospheric evaporation and the ejecta meet at locations near the loop apexes. The dynamics of this jet allows a unique opportunity to diagnose the chromospheric evaporation from the remote footpoints, from which we deduce a velocity in the range of 330--880 km/s.

preprint2019arXiv

Data compression for turbulence databases using spatio-temporal sub-sampling and local re-simulation

Motivated by specific data and accuracy requirements for building numerical databases of turbulent flows, data compression using spatio-temporal sub-sampling and local re-simulation is proposed. Numerical re-simulation experiments for decaying isotropic turbulence based on sub-sampled data are undertaken. The results and error analyses are used to establish parameter choices for sufficiently accurate sub-sampling and sub-domain re-simulation.

preprint2014arXiv

A LabVIEW based user-friendly X-ray phase-contrast imaging system software platform

X-ray phase-contrast imaging can provide greatly improved contrast over conventional absorption-based imaging for weakly absorbing samples, such as biological soft tissues and fibre composites. In this manuscript, we introduce an easy and fast way to develop a user-friendly software platform dedicated to the new grating-based X-ray phase-contrast imaging setup recently built at the National Synchrotron Radiation Laboratory of the University of Science and Technology of China. Unified management and control of 21 motorized positioning stages, of an ultra-precision piezoelectric translation stage and of the X-ray tube are achieved with this platform. The software package also covers the automatic image acquisition of the phase-stepping scanning with a flat panel detector. Moreover, a data post-processing module for signals retrieval and other custom features are in principle available. With a seamless integration of all necessary functions in a unique package, this software platform will greatly support the user activity during experimental runs.

preprint2014arXiv

A user-friendly nano-CT image alignment and 3D reconstruction platform based on LabVIEW

X-ray computed tomography at the nanometer scale (nano-CT) offers a wide range of applications in scientific and industrial areas. Here we describe a reliable, user-friendly and fast software package based on LabVIEW that may allow to perform all procedures after the acquisition of raw projection images in order to obtain the inner structure of the investigated sample. A suitable image alignment process to address misalignment problems among image series due to mechanical manufacturing errors, thermal expansion and other external factors has been considered together with a novel fast parallel beam 3D reconstruction procedure, developed ad hoc to perform the tomographic reconstruction. Remarkably improved reconstruction results obtained at the Beijing Synchrotron Radiation Facility after the image calibration confirmed the fundamental role of this image alignment procedure that minimizes unwanted blurs and additional streaking artifacts always present in reconstructed slices. Moreover, this nano-CT image alignment and its associated 3D reconstruction procedure fully based on LabVIEW routines, significantly reduce the data post-processing cycle, thus making faster and easier the activity of the users during experimental runs.