Researcher profile

Yuxiang Xing

Yuxiang Xing contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

Fluence Adaptation for Task-based Dose Optimization in X-ray Phase-Contrast Imaging

Purpose: Grating-based imaging (GBI) and edge-illumination (EI) are two promising types of XPCI as the conventional x-ray sources can be directly utilized. For GBI and EI systems, the phase-stepping acquisition with multiple exposures at a constant fluence is usually adopted in the literature. This work, however, attempts to challenge such a constant fluence concept during the phase-stepping process and proposes a fluence adaptation mechanism for dose reduction. Method: Recently, analytic multi-order moment analysis has been proposed to improve the computing efficiency. In these algorithms, multiple contrasts can be calculated by summing together the weighted phase-stepping curves (PSCs) with some kernel functions, which suggests us that the raw data at different steps have different contributions for the noise in retrieved contrasts. Based on analytic retrieval formulas and the Gaussian noise model for detected signals, we derived an optimal adaptive fluence distribution, which is proportional to the absolute weighting kernel functions and the root of original sample PSCs acquired under the constant fluence. Results: To validate our analyses, simulations and experiments are conducted for GBI and EI systems. Simulated results demonstrate that the dose reduction ratio between our proposed fluence distributions and the typical constant one can be about 20% for the phase contrast, which is consistent with our theoretical predictions. Although the experimental noise reduction ratios are a little smaller than the theoretical ones, synthetic and real experiments both observe better noise performance by our proposed method. Our simulated results also give out the effective ranges of the parameters of the PSCs, such as the visibility in GBI, the standard deviation and the mean value in EI, providing a guidance for the use of our proposed approach in practice.

preprint2020arXiv

A novel deep learning-based method for monochromatic image synthesis from spectral CT using photon-counting detectors

With the growing technology of photon-counting detectors (PCD), spectral CT is a widely concerned topic which has the potential of material differentiation. However, due to some non-ideal factors such as cross talk and pulse pile-up of the detectors, direct reconstruction from detected spectrum without any corrections will get a wrong result. Conventional methods try to model these factors using calibration and make corrections accordingly, but depend on the preciseness of the model. To solve this problem, in this paper, we proposed a novel deep learning-based monochromatic image synthesis method working in sinogram domain. Different from previous deep learning-based methods aimed at this problem, we designed a novel network architecture according to the physical model of cross talk, and it can solve this problem better in an ingenious way. Our method was tested on a cone-beam CT (CBCT) system equipped with a PCD. After using FDK algorithm on the corrected projection, we got quite more accurate results with less noise, which showed the feasibility of monochromatic image synthesis by our method.

preprint2019arXiv

Truncated analytic moment analysis and its hybrid-field contrast in grating-based x-ray phase contrast imaging

For grating-based x-ray phase contrast imaging (GPCI), a multi-order moment analysis (MMA) has been recently developed to obtain multiple contrasts from the ultra-small-angle x-ray scattering distribution, as a novel information retrieval approach that is totally different from the conventional Fourier components analysis (FCA). In this paper, we present an analytic form of MMA in theory that can retrieve multiple contrasts directly from raw phase-stepping images, with no scattering distribution involved. For practical implementation, a truncated analytic analysis (called as TA-MMA) is adopted and it is hundreds of times faster in computation than the original deconvolution-based MMA (called as DB-MMA). More importantly, TA-MMA is proved to establish a quantitative connection between FCA and MMA, i.e., the first-order moment computed by TA-MMA is essentially the product of the phase contrast and the dark-field contrast retrieved by FCA, providing a new physical parameter for GPCI. The new physical parameter, in fact, can be treated as a ``hybrid-field'' contrast as it fuses the original phase contrast and dark-field contrast in a straightforward manner, which may be the first physical fusion contrast in GPCI to our knowledge and may have a potential to be directly used in practical applications.