Researcher profile

Hewei Gao

Hewei Gao contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2024arXiv

Fast KV-Switching and Dual-Layer Flat-Panel Detector Enabled Cone-Beam CT Joint Spectral Imaging

Purpose: Fast kV-switching (FKS) and dual-layer flat-panel detector (DL-FPD) technologies have been actively studied as promising dual-energy solutions for FPD-based cone-beam computed tomography (CBCT). However, CBCT spectral imaging is known to face challenges in obtaining accurate and robust material discrimination performance due to the limited energy separation. To further improve CBCT spectral imaging capability, this work aims to promote a source-detector joint spectral imaging solution which takes advantages of both FKS and DL-FPD, and to conduct a feasibility study on the first tabletop CBCT system with the joint spectral imaging capability developed. Methods: In this work, the first FKS and DL-FPD jointly enabled multi-energy tabletop CBCT system has been developed in our laboratory. To evaluate its spectral imaging performance, a set of physics experiments are conducted, where the multi-energy and head phantoms are scanned using the 80/105/130kVp switching pairs and projection data are collected using a prototype DL-FPD. To compensate for the slightly angular mismatch between the low- and high-energy projections in FKS, a dual-domain projection completion scheme is implemented. Afterwards material decomposition is carried out by using the maximum-likelihood method, followed by reconstruction of basis material and virtual monochromatic images. Results: The physics experiments confirmed the feasibility and superiority of the joint spectral imaging, whose CNR of the multi-energy phantom were boosted by an average improvement of 21.9%, 20.4% for water and 32.8%, 62.8% for iodine when compared with that of the FKS and DL-FPD in fan-beam and cone-beam experiments, respectively. Conclusions: A feasibility study of the joint spectral imaging for CBCT by utilizing both the FKS and DL-FPD was conducted, with the first tabletop CBCT system having such a capability being developed.

preprint2021arXiv

Fluence Adaptation for Task-based Dose Optimization in X-ray Phase-Contrast Imaging

Purpose: Grating-based imaging (GBI) and edge-illumination (EI) are two promising types of XPCI as the conventional x-ray sources can be directly utilized. For GBI and EI systems, the phase-stepping acquisition with multiple exposures at a constant fluence is usually adopted in the literature. This work, however, attempts to challenge such a constant fluence concept during the phase-stepping process and proposes a fluence adaptation mechanism for dose reduction. Method: Recently, analytic multi-order moment analysis has been proposed to improve the computing efficiency. In these algorithms, multiple contrasts can be calculated by summing together the weighted phase-stepping curves (PSCs) with some kernel functions, which suggests us that the raw data at different steps have different contributions for the noise in retrieved contrasts. Based on analytic retrieval formulas and the Gaussian noise model for detected signals, we derived an optimal adaptive fluence distribution, which is proportional to the absolute weighting kernel functions and the root of original sample PSCs acquired under the constant fluence. Results: To validate our analyses, simulations and experiments are conducted for GBI and EI systems. Simulated results demonstrate that the dose reduction ratio between our proposed fluence distributions and the typical constant one can be about 20% for the phase contrast, which is consistent with our theoretical predictions. Although the experimental noise reduction ratios are a little smaller than the theoretical ones, synthetic and real experiments both observe better noise performance by our proposed method. Our simulated results also give out the effective ranges of the parameters of the PSCs, such as the visibility in GBI, the standard deviation and the mean value in EI, providing a guidance for the use of our proposed approach in practice.

preprint2020arXiv

An Analysis of Scatter Characteristics in X-ray CT Spectral Correction

X-ray scatter remains a major physics challenge in volumetric computed tomography (CT), whose physical and statistical behaviors have been commonly leveraged in order to eliminate its impact on CT image quality. In this work, we conduct an in-depth derivation of how the scatter distribution and scatter to primary ratio (SPR) will change during the spectral correction, leading to an interesting finding on the property of scatter: when applying the spectral correction before scatter is removed, the impact of SPR on a CT projection will be scaled by the first derivative of the mapping function; while the scatter distribution in the transmission domain will be scaled by the product of the first derivative of the mapping function and a natural exponential of the projection difference before and after the mapping. Such a characterization of scatter's behavior provides an analytic approach of compensating for the SPR as well as approximating the change of scatter distribution after spectral correction, even though both of them might be significantly distorted as the linearization mapping function in spectral correction could vary a lot from one detector pixel to another. We conduct an evaluation of SPR compensations on a Catphan phantom and an anthropomorphic chest phantom to validate the characteristics of scatter. In addition, this scatter property is also directly adopted into CT imaging using a spectral modulator with flying focal spot technology (SMFFS) as an example to demonstrate its potential in practical applications.

preprint2019arXiv

Truncated analytic moment analysis and its hybrid-field contrast in grating-based x-ray phase contrast imaging

For grating-based x-ray phase contrast imaging (GPCI), a multi-order moment analysis (MMA) has been recently developed to obtain multiple contrasts from the ultra-small-angle x-ray scattering distribution, as a novel information retrieval approach that is totally different from the conventional Fourier components analysis (FCA). In this paper, we present an analytic form of MMA in theory that can retrieve multiple contrasts directly from raw phase-stepping images, with no scattering distribution involved. For practical implementation, a truncated analytic analysis (called as TA-MMA) is adopted and it is hundreds of times faster in computation than the original deconvolution-based MMA (called as DB-MMA). More importantly, TA-MMA is proved to establish a quantitative connection between FCA and MMA, i.e., the first-order moment computed by TA-MMA is essentially the product of the phase contrast and the dark-field contrast retrieved by FCA, providing a new physical parameter for GPCI. The new physical parameter, in fact, can be treated as a ``hybrid-field'' contrast as it fuses the original phase contrast and dark-field contrast in a straightforward manner, which may be the first physical fusion contrast in GPCI to our knowledge and may have a potential to be directly used in practical applications.