Source author record

Yann Le Coq

Yann Le Coq appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2016arXiv

Dispersive coupling between light and a rare-earth ion doped mechanical resonator

By spectrally hole burning an inhomogeneously broadened ensemble of ions while applying a controlled perturbation, one can obtain spectral holes that are functionalized for maximum sensitivity to different perturbations. We propose to use such hole burnt structures for the dispersive optical interaction with rare-earth ion dopants whose frequencies are sensitive to crystal strain due to the bending motion of a crystal cantilever. A quantitative analysis shows that good optical sensitivity to the bending motion is obtained if a magnetic field gradient is applied across the crystal during hole burning, and that the resulting opto-mechanical coupling strength is sufficient for observing quantum features such as zero point vibrations.

preprint2016arXiv

Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock

Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.

preprint2014arXiv

Quantum cascade laser frequency stabilisation at the sub-Hz level

Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. The comb is stabilised to a remote near-infrared ultra-stable laser referenced to frequency primary standards, whose signal is transferred via an optical fibre link. The stability and frequency traceability of our QCL exceed those demonstrated so far by two orders of magnitude. As a demonstration of its capability, we then use it to perform high-resolution molecular spectroscopy. We measure absorption frequencies with an 8x10-13 relative uncertainty. This confirms the potential of this setup for ultra-high precision measurements with molecules, such as our ongoing effort towards testing the parity symmetry by probing chiral species.

preprint2013arXiv

Mid-infrared laser phase-locking to a remote near-infrared frequency reference for high precision molecular spectroscopy

We present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 $μ$m with a state-of-the-art uncertainty of 8x10-13. We also demonstrate the frequency stabilization of a mid-infrared laser with fractional stability better than 4x10-14 at 1 s averaging time and a line-width below 17 Hz. This new stabilization scheme gives us the ability to transfer frequency stability in the range of 10-15 or even better, currently accessible in the near-infrared or in the visible, to mid-infrared lasers in a wide frequency range.

preprint2013arXiv

Spectral purity transfer between optical wavelengths at the $10^{-18}$ level

Ultra-stable lasers and optical frequency combs have been the enabling technologies for the tremendous progress of precise optical spectroscopy in the last ten years. To improve laser frequency stabilization beyond the thermal-noise fundamental limit of traditional room-temperature high-finesse optical cavities, new solutions have been recently developed. These being complex and often wavelength specific, the capability to transfer their spectral purity to any optical wavelengths is highly desirable. Here we present an optical frequency comb based scheme transferring a $4.5 \times 10^{-16}$ fractional frequency stability from a 1062 nm wavelength laser to a 1542 nm laser. We demonstrate that this scheme does not hinder the transfer down to $3 \times 10^{-18}$ at one second, two orders of magnitude below previously reported work with comparable systems. This exceeds by more than one order of magnitude the stability of any optical oscillator demonstrated to date, and satisfies the stability requirement for quantum-projection-noise limited optical lattice clocks.

preprint2012arXiv

Mid-IR frequency measurement using an optical frequency comb and a long-distance remote frequency reference

We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an ultrastable 1.55 $μ$m frequency reference signal, transferred from LNE-SYRTE to LPL through an optical link. We are now progressing towards the stabilization of the mid-IR laser via the frequency comb and the extension of this technique to quantum cascade lasers. Such a development is very challenging for ultrahigh resolution molecular spectroscopy and fundamental tests of physics with molecules.

preprint2007arXiv

Accuracy Evaluation of an Optical Lattice Clock with Bosonic Atoms

We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is determined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss the conditions necessary to reach a clock accuracy of 10^{-17} or less using this scheme.

preprint2005arXiv

Coherent matter wave inertial sensors for precision measurements in space

We analyze the advantages of using ultra-cold coherent sources of atoms for matter-wave interferometry in space. We present a proof-of-principle experiment that is based on an analysis of the results previously published in [Richard et al., Phys. Rev. Lett., 91, 010405 (2003)] from which we extract the ratio h/m for 87Rb. This measurement shows that a limitation in accuracy arises due to atomic interactions within the Bose-Einstein condensate.

preprint2005arXiv

Partially ferromagnetic electromagnet for trapping and cooling neutral atoms to quantum degeneracy

We have developed a compact partially ferromagnetic electromagnet to produce a Ioffe-Pritchard trap for neutral atoms. Our structure permits strong magnetic confinement with low power consumption. Compared to the previous iron-core electromagnet, it allows for easy compensation of remnant fields and very high stability, along with cost-effective realization and compactness. We describe and characterize our apparatus and demonstrate trapping and cooling of Rb 87 atoms to quantum degeneracy. Pure Bose-Einstein condensates containing 10^6 atoms are routinely realized on a half-minute cycle. In addition we test the stability of the magnetic trap by producing atom lasers.

preprint2005arXiv

Tapered-amplified AR-coated laser diodes for Potassium and Rubidium atomic-physics experiments

We present a system of room-temperature extended-cavity grating-diode lasers (ECDL) for production of light in the range 760-790nm. The extension of the tuning range towards the blue is permitted by the weak feedback in the cavity: the diodes are anti-reflection coated, and the grating has just 10% reflectance. The light is then amplified using semiconductor tapered amplifiers to give more than 400mW of power. The outputs are shown to be suitable for atomic physics experiments with potassium (767nm), rubidium (780nm) or both, of particular relevance to doubly-degenerate boson-fermion mixtures.