Researcher profile

Yang-heng Zheng

Yang-heng Zheng contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
8works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2016arXiv

Charmed baryon decay asymmetry in e+e- annihilation

We propose to measure the decay asymmetry parameters in the hadronic weak decays of singly charmed baryons, such as $\ldc\to\ldπ^+,Σ^0π^+,p \bar K_0$, $Ξ_c^0\toΞ^-π^+$ and $Ω_c^0\toΩ^-π^+$. The joint angular formulae for these processes are presented, and are used to extract the asymmetry parameters in $\ee$ annihilation data. Base on the current $\ldc$ data set collected at BESIII, we estimate the experimental sensitivities to measure the parameters $α_{\ldπ^+}$ for $\ldc\to\ldπ^+$, $α_{Σ^+π^0}$ for $\ldc\toΣ^+π^0$ and $α_{\usigπ^+}$ for $\ldc\to\usigπ^+$.

preprint2016arXiv

Radiation Studies for the Target Station of the MOMENT

The discovery of the neutrino mixing angle $θ_{13}$ opens new opportunities for the discovery of the leptonic CP violation for high intensity neutrino beams. MOMENT a future neutrino facility with a high-power proton beam of 15 MW from a continuous-wave linac is focused on that discovery. The high power of the proton beam causes extreme radiation conditions for the facility and especially for the target station where the pion capture system of five superconducting solenoids is located. In this paper initial studies are performed for the effects of the radiation on the solenoid structure and the area surrounding it. A concept cooling system is also proposed.

preprint2016arXiv

Study of a sealed high gas pressure THGEM detector and response of Alpha particle spectra

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under high pressure of 2 atm mainly consist in selecting optimal voltages for ionization region and induction region. The dependence of the shape of Alpha particle spectra measured with relative gas gain on gas pressure (1.3 $\sim$ 2.0 atm) has been studied. The 8 groups of relative gas gain versus working voltage of THGEM expressed by weighting filed $E/P$ are normalized, being consistent with theory. The results show that the air tightness of the chamber is good measured by a sensitive barometer and checked with gas gain. The experimental results are compared with Monte Carlo simulation on energy deposition without gas gain involved.

preprint2014arXiv

MOMENT: a muon-decay medium-baseline neutrino beam facility

Neutrino beam with about 300 MeV in energy, high-flux and medium baseline is considered a rational choice for measuring CP violation before the more powerful Neutrino Factory will be built. Following this concept, a unique neutrino beam facility based on muon-decayed neutrinos is proposed. The facility adopts a continuous-wave proton linac of 1.5 GeV and 10 mA as the proton driver, which can deliver an extremely high beam power of 15 MW. Instead of pion-decayed neutrinos, unprecedentedly intense muon-decayed neutrinos are used for better background discrimination. The schematic design for the facility is presented here, including the proton driver, the assembly of a mercury-jet target and capture superconducting solenoids, a pion/muon beam transport line, a long muon decay channel of about 600 m and the detector concept. The physics prospects and the technical challenges are also discussed.

preprint2013arXiv

Experimental studies of THGEM in different Ar/CO2 mixtures

In this paper, the performances of a type of the domestic THGEM (THick Gaseous Electron Multiplier) working in the Ar/CO2 mixtures are reported in details. This kind of single THGEM can provide the gain range from 100 to 1000, which is very suitable for the application in the neutron detection. In order to study its basic characteristics as the references for the development of THGEM based neutron detector, the counting rate plateau, the energy resolution and the gain of the THGEM have been measured in the different Ar/CO2 mixtures with the change of the electrical fields. For the Ar/CO2(90%/10%) gas mixture, a wide counting rate plateau is got from 720V to 770V with the plateau slope of 2.4% / 100 V and the excellent energy resolution about 22% is obtained at the 5.9keV full energy peak of the 55Fe X-ray source.

preprint2011arXiv

The Online Data Quality Monitoring System at BESIII

The online Data Quality Monitoring (DQM) plays an important role in the data taking process of HEP experiments. BESIII DQM samples data from online data flow, reconstructs them with offline reconstruction software, and automatically analyzes the reconstructed data with user-defined algorithms. The DQM software is a scalable distributed system. The monitored results are gathered and displayed in various formats, which provides the shifter with current run information that can be used to find problems early. This paper gives an overview of DQM system at BESIII.

preprint2008arXiv

A simulation study on the measurement of D0-D0bar mixing parameter y at BES-III

We established a method on measuring the $\dzdzb$ mixing parameter $y$ for BESIII experiment at the BEPCII $e^+e^-$ collider. In this method, the doubly tagged $ψ(3770) \to D^0 \overline{D^0}$ events, with one $D$ decays to CP-eigenstates and the other $D$ decays semileptonically, are used to reconstruct the signals. Since this analysis requires good $e/π$ separation, a likelihood approach, which combines the $dE/dx$, time of flight and the electromagnetic shower detectors information, is used for particle identification. We estimate the sensitivity of the measurement of $y$ to be 0.007 based on a $20fb^{-1}$ fully simulated MC sample.