Source author record

Y. Sugiyama

Y. Sugiyama appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Update of beam coupling impedance evaluation by the stretched-wire method

In many cases beam coupling impedances or wake fields are calculated with computer simulator such as CST Studio Suite, GdfidL Electromagnetic Field Simulator and so on. But evaluation with the stretched-wire method is still very useful by its flexibility to the change of the device-under-test configuration, speed to get results and, more than anything, its accessibility on the real devices. One of the drawbacks in the practical procedure, difficulty of Thru-Reflect-Line calibration, is overcome using the calibration method recently introduced in high frequency vector network analyzers, "2-X THRU de-embedding". Here the procedure is explained in detail. The method has been successfully applied to RF cavity and FX kicker measurement in the J-PARC MR.

preprint2015arXiv

Photon-Veto Counters at the Outer Edge of the Endcap Calorimeter for the KOTO Experiment

The Outer-Edge Veto (OEV) counter subsystem for extra-photon detection from the backgrounds for the? $K^0_L\rightarrowπ^0ν\barν$ decay is located at the outer edge of the endcap CsI calorimeter of the KOTO experiment at J-PARC. The subsystem is composed of 44 counters with different cross-sectional shapes. All counters are made of lead and scintillator plates and read out through wavelength-shifting fibers. In this paper, we discuss the design and performances of the OEV counters under heavy load ($\sim8$ tons/m$^2$) in vacuum. For 1-MeV energy deposit, the average light yield and time resolution are 20.9 photo-electrons and 1.5 ns, respectively. Although no pronounced peak by minimum-ionizing particles is observed in the energy distributions, an energy calibration method with cosmic rays works well in monitoring the gain stability with an accuracy of a few percent.

preprint2010arXiv

Measure valued solutions of the 2D Keller-Segel system

We study the solutions of the two-dimensional Keller-Segel system describing chemotaxis. The Keller-Segel system as well as the properties of the blow-up set has been extensively studied. In this paper we obtain generalized solutions for the Keller-Segel system in the sense of measures as the limit of two-different regularizations of it. We will show that the resulting limit measures, that are in some suitable sense global weak solutions of the Keller-Segel system, depend in the regularization.