Source author record

Y. Miura

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

7works
6topics
4close collaborators

Published work

7 publications

preprint2020arXiv

Enhancement of anomalous Nernst effect in Ni/Pt superlattice

We report an enhancement of the anomalous Nernst effect (ANE) in Ni/Pt (001) epitaxial superlattices. The transport and magneto-thermoelectric properties were investigated for the Ni/Pt superlattices with various Ni layer thicknesses (t{\it t}). The anomalous Nernst coefficient was increased up to more than 1 μμV K−1^{-1} for 2.0 nm ≤{\leq} t{\it t} ≤{\leq} 4.0 nm, which was the remarkable enhancement compared to the bulk Ni. It has been found that the large transverse Peltier coefficient (ααxy_{xy}), reaching ααxy_{xy} = 4.8 A K−1^{-1} m−1^{-1} for t{\it t} = 4.0 nm, plays a prime role for the enhanced ANE of the Ni/Pt (001) superlattices.

preprint2019arXiv

Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models

We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of 1 × 1 1\,\times\,1\,cm2^{2} and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.

preprint2019arXiv

Beam test performance of the highly granular SiW-ECAL technological prototype for the ILC

The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors, with each sensor containing an array of 256 5.5×5.55.5\times5.5 mm2^2 silicon PIN diodes. The four sensors covered a total area of 18×1818\times18 cm2^2, and comprised a total of 1024 channels. The readout was split into a trigger line and a charge signal line. Key performance results for signal over noise for the two output lines are presented, together with a study of the uniformity of the detector response. Measurements of the response to electrons for the tungsten loaded version of the detector are also presented.

preprint2015arXiv

Electronic and magnetic properties of off-stoichiometric Co2_\mathrm{2}Mnβ_βSi/MgO interfaces studied by x-ray magnetic circular dichroism

We have studied the electronic and magnetic states of Co and Mn atoms at the interface of the Co2_\mathrm{2}Mnβ_βSi (CMS)/MgO (ββ=0.69, 0.99, 1.15 and 1.29) magnetic tunnel junction (MTJ) by means of x-ray magnetic circular dichroism. In particular, the Mn composition (ββ) dependences of the Mn and Co magnetic moments were investigated. The experimental spin magnetic moments of Mn, mspinm_\mathrm{spin}(Mn), derived from XMCD weakly decreased with increasing Mn composition ββ in going from Mn-deficient to Mn-rich CMS films. This behavior was explained by first-principles calculations based on the antisite-based site-specific formula unit (SSFU) composition model, which assumes the formation of only antisite defect, not vacancies, to accommodate off-stoichiometry. Furthermore, the experimental spin magnetic moments of Co, mspinm_\mathrm{spin}(Co), also weakly decreased with increasing Mn composition. This behavior was consistently explained by the antisite-based SSFU model, in particular, by the decrease in the concentration of CoMn_\mathrm{Mn} antisites detrimental to the half-metallicity of CMS with increasing ββ. This finding is consistent with the higher TMR ratios which have been observed for CMS/MgO/CMS MTJs with Mn-rich CMS electrodes.

preprint2015arXiv

Precise determination of Λ12^{12}_ΛC level structure by γγ-ray spectroscopy

Level structure of the Λ12^{12}_ΛC hypernucleus was precisely determined by means of γγ-ray spectroscopy. We identified four γγ-ray transitions via the 12^{12}C(π+,K+γ)(π^{+},K^{+}γ) reaction using a germanium detector array, Hyperball2. The spacing of the ground-state doublet (21−,11−)(2^{-}_{1},1^{-}_{1}) was measured to be 161.5±0.3(stat)±0.3(syst)161.5\pm0.3\text{(stat)}\pm0.3\text{(syst)}\,keV from the direct M1M1 transition. Excitation energies of the 12−1^{-}_{2} and 13−1^{-}_{3} states were measured to be 2832±3±42832\pm3\pm4\,keV and 6050±8±76050\pm8\pm7\,keV, respectively. The obtained level energies provide definitive references for the reaction spectroscopy of ΛΛ hypernuclei.

preprint2007arXiv

Photoproduction of neutral kaons on the liquid deuterium target in the threshold region

The photoproduction process of neutral kaons on a liquid deuterium target is investigated near the threshold region, Egamma = 0.8-1.1 GeV. K0 events are reconstructed from positive and negative pions, and differential cross sections are derived. Experimental momentum spectra are compared with those calculated in the spectator model using a realistic deuteron wave function. Elementary amplitudes as given by recent isobar models and a simple phenomenological model are used to study the effect of the new data on the angular behavior of the elementary cross section. The data favor a backward-peaked angular distribution of the elementary n(gamma,K0)Lambda process, which provides additional constraints on current models of kaon photoproduction. The present study demonstrates that the n(gamma,K0)Lambda reaction can provide key information on the mechanism of the photoproduction of strangeness.

preprint2005arXiv

Exclusive Measurement of the Nonmesonic Weak Decay of ^{5}_ΛHe Hypernucleus

We performed a coincidence measurement of two nucleons emitted from the nonmesonic weak decay (NMWD) of ^{5}_ΛHe formed via the ^{6}Li(π^+,K^+) reaction. The energies of two nucleons and the pair number distributions in the opening angle between them were measured. In both np and nn pairs, we observed a clean back-to-back correlation coming from the two-body decay of Λp --> n p and Λn --> n n, respectively. The ratio of the nucleon pair numbers was N_{nn}/N_{np}=0.45 \pm 0.11(stat)\pm 0.03(syst) in the kinematic region of cos(theta_{NN}) < -0.8. Since each decay mode was exclusively detected, the measured ratio should be close to the ratio of Γ(Λp --> np)/Γ(Λn --> nn). The ratio is consistent with recent theoretical calculations based on the heavy meson/direct quark exchange picture.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.