Researcher profile

Xuanqin Mou

Xuanqin Mou contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2023arXiv

Task-based Assessment of Deep Networks for Sinogram Denoising with A Transformer-based Observer

A variety of supervise learning methods are available for low-dose CT denoising in the sinogram domain. Traditional model observers are widely employed to evaluate these methods. However, the sinogram domain evaluation remains an open challenge for deep learning-based low-dose CT denoising. Since each lesion in medical CT images corresponds to a narrow sinusoidal strip in sinogram domain, here we proposed a transformer-based model observer to evaluate sinogram domain supervised learning methods. The numerical results indicate that our transformer-based model well-approximates the Laguerre-Gauss channelized Hotelling observer (LG-CHO) for a signal-known-exactly (SKE) and background-known-statistically (BKS) task. The proposed model observer is employed to assess two classic CNN-based sinogram domain denoising methods. The results demonstrate a utility and potential of this transformer-based observer model in developing deep low-dose CT denoising methods in the sinogram domain.

preprint2022arXiv

AutoMO-Mixer: An automated multi-objective Mixer model for balanced, safe and robust prediction in medicine

Accurately identifying patient's status through medical images plays an important role in diagnosis and treatment. Artificial intelligence (AI), especially the deep learning, has achieved great success in many fields. However, more reliable AI model is needed in image guided diagnosis and therapy. To achieve this goal, developing a balanced, safe and robust model with a unified framework is desirable. In this study, a new unified model termed as automated multi-objective Mixer (AutoMO-Mixer) model was developed, which utilized a recent developed multiple layer perceptron Mixer (MLP-Mixer) as base. To build a balanced model, sensitivity and specificity were considered as the objective functions simultaneously in training stage. Meanwhile, a new evidential reasoning based on entropy was developed to achieve a safe and robust model in testing stage. The experiment on an optical coherence tomography dataset demonstrated that AutoMO-Mixer can obtain safer, more balanced, and robust results compared with MLP-Mixer and other available models.

preprint2014arXiv

Improved Scatter Correction in X-Ray Cone Beam CT with Moving Beam Stop Array Using Johns' Equation

In this paper, an improved scatter correction with moving beam stop array (BSA) for x-ray cone beam (CB) CT is proposed. Firstly, correlation between neighboring CB views is deduced based on John's Equation. Then, correlation-based algorithm is presented to complement the incomplete views by using the redundancy (over-determined information) in CB projections. Finally, combining the algorithm with scatter correction method using moving BSA, where part of primary radiation is blocked and incomplete projections are acquired, an improved correction method is proposed. Effectiveness and robustness is validated by Monte Carlo (MC) simulation with EGSnrc on humanoid phantom.

preprint2014arXiv

Single-scan scatter correction in CBCT by using projection correlation based view interpolation (PC-VI) and a stationary ring-shaped beam stop array (BSA)

In the scatter correction for x-ray Cone Beam (CB) CT, the single-scan scheme with moving Beam Stop Array (BSA) offers reliable scatter measurement with low dose, and by using Projection Correlation based View Interpolation (PC-VI), the primary fluence shaded by the moving BSA (during scatter measurement) could be recovered with high accuracy. However, the moving BSA may increase the mechanical burden in real applications. For better practicability, in this paper we proposed a PC-VI based single-scan scheme with a ring-shaped stationary BSA, which serves as a virtual moving BSA during CB scan, so the shaded primary fluence by this stationary BSA can be also well recovered by PC-VI. The principle in designing the whole system is deduced and evaluated. The proposed scheme greatly enhances the practicability of the single-scan scatter correction scheme.