Published work

4 published item(s)

preprint2022arXiv

Transition edge sensor based detector: from X-ray to $γ$-ray

The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies below 10 keV have very weak penetrating ability, so only a few microns thick of gold or bismuth can obtain quantum efficiency higher than 70\%. Therefore, the entire structure of the TES X-ray detector in this energy range can be realized in the microfabrication process. However, for X-rays or gamma rays from 10 keV to 200 keV, sub-millimeter absorber layers are required, which cannot be realized by microfabrication process. This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems built by ShanghaiTech University, then focus on the introduction of the TES $γ$-ray detector, with absorber based on an sub-millimeter lead-tin alloy sphere. The detector has a quantum efficiency above 70\% near 100 keV, and an energy resolution of about 161.5eV@59.5keV.

preprint2016arXiv

Design and optimization of resistive anode for a two-dimensional imaging triple-GEM detector

The optimization of resistive anode for two dimensional imaging detectors which consists of a series of high resistive square pads surrounding by low resistive strips has been studied by both numerical simulations and experimental tests. It has been found that to obtain good detector performance, the resistance ratio of the pad to the strip should be larger than 5, the nonuniformity of the pad surface resistivity had better be less than $20\%$, a smaller pad width leads to a smaller spatial resolution and when the pad width is $6mm$, the spatial resolution ($σ$) can reach about $105μm$. Based on the study results, a 2-D GEM detector prototype with the optimized resistive anode is constructed and a good imaging performance is achieved.

preprint2016arXiv

Development of a two-dimensional imaging GEM detector using the resistive anode readout method with $6\times6$ cells

We report the application of the resistive anode readout method on a two dimensional imaging GEM detector. The resistive anode consists of $6\times6$ cells with the cell size $6~\mathrm{mm}\times6~\mathrm{mm}$. New electronics and DAQ system are used to process the signals from the 49 readout channels. The detector has been tested by using the X-ray tube (8~keV). The spatial resolution of the detector is about $103.46~\mathrm{μm}$ with the detector response part about $66.41~\mathrm{μm}$. The nonlinearity of the detector is less than $1.5\%$. A quite good two dimensional imaging capability is achieved as well. The performances of the detector show the prospect of the resistive anode readout method for the large readout area imaging detectors.

preprint2015arXiv

Study of cluster reconstruction and track fitting algorithms for CGEM-IT at BESIII

Considering the aging effects of existing Inner Drift Chamber (IDC) of BES\uppercase\expandafter{\romannumeral3}, a GEM based inner tracker is proposed to be designed and constructed as an upgrade candidate for IDC. This paper introduces a full simulation package of CGEM-IT with a simplified digitization model, describes the development of the softwares for cluster reconstruction and track fitting algorithm based on Kalman filter method for CGEM-IT. Preliminary results from the reconstruction algorithms are obtained using a Monte Carlo sample of single muon events in CGEM-IT.