Researcher profile

Ming-Yi Dong

Ming-Yi Dong contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2016arXiv

Design and optimization of resistive anode for a two-dimensional imaging triple-GEM detector

The optimization of resistive anode for two dimensional imaging detectors which consists of a series of high resistive square pads surrounding by low resistive strips has been studied by both numerical simulations and experimental tests. It has been found that to obtain good detector performance, the resistance ratio of the pad to the strip should be larger than 5, the nonuniformity of the pad surface resistivity had better be less than $20\%$, a smaller pad width leads to a smaller spatial resolution and when the pad width is $6mm$, the spatial resolution ($σ$) can reach about $105μm$. Based on the study results, a 2-D GEM detector prototype with the optimized resistive anode is constructed and a good imaging performance is achieved.

preprint2016arXiv

Development of a two-dimensional imaging GEM detector using the resistive anode readout method with $6\times6$ cells

We report the application of the resistive anode readout method on a two dimensional imaging GEM detector. The resistive anode consists of $6\times6$ cells with the cell size $6~\mathrm{mm}\times6~\mathrm{mm}$. New electronics and DAQ system are used to process the signals from the 49 readout channels. The detector has been tested by using the X-ray tube (8~keV). The spatial resolution of the detector is about $103.46~\mathrm{μm}$ with the detector response part about $66.41~\mathrm{μm}$. The nonlinearity of the detector is less than $1.5\%$. A quite good two dimensional imaging capability is achieved as well. The performances of the detector show the prospect of the resistive anode readout method for the large readout area imaging detectors.

preprint2016arXiv

Track segment finding with CGEM-IT and matching to tracks in ODC

The relative differences in coordinates of Cylindrical-Gas-Electron-Multiplier-Detector-based Inner Tracker (CGEM-IT) clusters are studied to search for track segments in CGEM-IT. With the full simulation of single muon track samples, clear patterns are found and parameterized for the correct cluster combinations. The cluster combinations satisfying the patterns are selected as track segment candidates in CGEM-IT with an efficiency higher than 99%. The parameters of the track segments are obtained by a helix fitting. Some chi-squared quantities, evaluating the differences in track parameters between the track segments in CGEM-IT and the tracks found in Outer-Drift-Chamber (ODC), are calculated and used to match them. Proper chi-squared requirements are determined as a function of transverse momentum and the matching efficiency is found reasonable.

preprint2015arXiv

Study of cluster reconstruction and track fitting algorithms for CGEM-IT at BESIII

Considering the aging effects of existing Inner Drift Chamber (IDC) of BES\uppercase\expandafter{\romannumeral3}, a GEM based inner tracker is proposed to be designed and constructed as an upgrade candidate for IDC. This paper introduces a full simulation package of CGEM-IT with a simplified digitization model, describes the development of the softwares for cluster reconstruction and track fitting algorithm based on Kalman filter method for CGEM-IT. Preliminary results from the reconstruction algorithms are obtained using a Monte Carlo sample of single muon events in CGEM-IT.