Source author record

Xinxin Li

Xinxin Li appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2023arXiv

Demonstration of an AI-driven workflow for autonomous high-resolution scanning microscopy

With the continuing advances in scientific instrumentation, scanning microscopes are now able to image physical systems with up to sub-atomic-level spatial resolutions and sub-picosecond time resolutions. Commensurately, they are generating ever-increasing volumes of data, storing and analysis of which is becoming an increasingly difficult prospect. One approach to address this challenge is through self-driving experimentation techniques that can actively analyze the data being collected and use this information to make on-the-fly measurement choices, such that the data collected is sparse but representative of the sample and sufficiently informative. Here, we report the Fast Autonomous Scanning Toolkit (FAST) that combines a trained neural network, a route optimization technique, and efficient hardware control methods to enable a self-driving scanning microscopy experiment. The key features of our method are that: it does not require any prior information about the sample, it has a very low computational cost, and that it uses generic hardware controls with minimal experiment-specific wrapping. We test this toolkit in numerical experiments and a scanning dark-field x-ray microscopy experiment of a $WSe_2$ thin film, where our experiments show that a FAST scan of <25% of the sample is sufficient to produce both a high-fidelity image and a quantitative analysis of the surface distortions in the sample. We show that FAST can autonomously identify all features of interest in the sample while significantly reducing the scan time, the volume of data acquired, and dose on the sample. The FAST toolkit is easy to apply for any scanning microscopy modalities and we anticipate adoption of this technique will empower broader multi-level studies of the evolution of physical phenomena with respect to time, temperature, or other experimental parameters.

preprint2016arXiv

Direct Imaging of Dynamic Glassy Behavior in a Strained Manganite Film

Complex many-body interaction in perovskite manganites gives rise to a strong competition between ferromagnetic metallic and charge ordered phases with nanoscale electronic inhomogeneity and glassy behaviors. Investigating this glassy state requires high resolution imaging techniques with sufficient sensitivity and stability. Here, we present the results of a near-field microwave microscope imaging on the strain driven glassy state in a manganite film. The high contrast between the two electrically distinct phases allows direct visualization of the phase separation. The low temperature microscopic configurations differ upon cooling with different thermal histories. At sufficiently high temperatures, we observe switching between the two phases in either direction. The dynamic switching, however, stops below the glass transition temperature. Compared with the magnetization data, the phase separation was microscopically frozen, while spin relaxation was found in a short period of time.

preprint2013arXiv

Batch-fabricated cantilever probes with electrical shielding for nanoscale dielectric and conductivity imaging

This paper presents the design and fabrication of batch-processed cantilever probes with electrical shielding for scanning microwave impedance microscopy. The diameter of the tip apex, which defines the electrical resolution, is less than 50 nm. The width of the stripline and the thicknesses of the insulation dielectrics are optimized for a small series resistance (< 5 W) and a small background capacitance (~ 1 pF), both critical for high sensitivity imaging on various samples. The coaxial shielding ensures that only the probe tip interacts with the sample. The structure of the cantilever is designed to be symmetric to balance the stresses and thermal expansions of different layers so that the cantilever remains straight under variable temperatures. Such shielded cantilever probes produced in the wafer scale will facilitate enormous applications on nanoscale dielectric and conductivity imaging.

preprint2012arXiv

Unexpected Surface Implanted Layer in Static Random Access Memory Devices Observed by Microwave Impedance Microscope

Real-space mapping of doping concentration in semiconductor devices is of great importance for the microelectronic industry. In this work, a scanning microwave impedance microscope (MIM) is employed to resolve the local conductivity distribution of a static random access memory (SRAM) sample. The MIM electronics can also be adjusted to the scanning capacitance microscopy (SCM) mode, allowing both measurements on the same region. Interestingly, while the conventional SCM images match the nominal device structure, the MIM results display certain unexpected features, which originate from a thin layer of the dopant ions penetrating through the protective layers during the heavy implantation steps.