Researcher profile

Xin-Hu Yan

Xin-Hu Yan contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Radiation and Ionization Energy Loss Simulation for GDH Sum Rule Experiment in Hall-A at Jefferson Lab

The radiation and ionization energy loss are presented for single arm Monte Carlo simulation for the GDH sum rule experiment in Hall-A at Jefferson Lab. Radiation and ionization energy loss are discussed for $^{12}C$ elastic scattering simulation. The relative momentum ratio $\frac{Δp}{p}$ and $^{12}C$ elastic cross section are compared without and with Radiation Energy Loss and a reasonable shape is obtained by the simulation. The total energy loss distribution is obtained, showing a Landau shape for $^{12}C$ elastic scattering. This simulation work will give good support for radiation correction analysis of the GDH sum rule experiment.

preprint2010arXiv

NaI (Tl) Calorimeter Calibration and Simulation for Coulomb Sum Rule Experiment in Hall-A at Jefferson Lab

A precision measurment of inclusive electron scattering cross sections was carried out at Jefferson Lab in the quasi-elastic region for ${^4}$He, ${^{12}}$C, ${^{56}}$Fe and ${^{208}}$Pb targets. Longitudinal ($R_{L}$) and transverse ($R_{T}$) response functions of nucleon were extracted in the momentum transfer range 0.55 GeV/c$\le$$|q|$$\le$1.0 GeV/c. To achieve the above goal, a NaI (Tl) calorimeter was used to distinguish good electrons from background including pions and low energy electrons rescattered from walls of the spectrometer magnets. Due to a large set of kinematics and changes in HV settings, a number of calibrations were performed for the NaI (Tl) detector. Corrections for a few blocks of NaI (Tl) with bad or no signal were applied. The resolution of NaI (Tl) detector after calibration reached $\frac{δE}{\sqrt{E}} \approx 3\%$ at E=1 GeV. The performance of NaI (Tl) detector was compared with a simulation.