Researcher profile

Xiaoshen Kang

Xiaoshen Kang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2023arXiv

Sensitivity of $CP$ Violation of $Λ$ decay in $J/ψ\to Λ\barΛ$ at STCF

The process of $J/ψ\to Λ\barΛ$ is studied using $1.0\times10^{12}$ $J/ψ$ Monte Carlo (MC) events at $\sqrt{s}$=3.097 GeV with a fast simulation software at future Super Tau Charm Facility (STCF). The statistical sensitivity for $CP$ violation is determined to be the order of $\mathcal{O} (10^{-4})$ by measuring the asymmetric parameters of the $Λ$ decay. Furthermore, the decay of $J/ψ\to Λ\barΛ$ also serves as a benchmark process to optimize the detector responses using the interface provided by the fast simulation software.

preprint2022arXiv

Timing performance simulation for 3D 4H-SiC detector

To meet high radiation challenge for detectors in future high-energy physics, a novel 3D 4H-SiC detector was investigated. SiC detectors could potentially operate in radiation harsh and room temperature environment because of its high thermal conductivity and high atomic displacement threshold energy. 3D structure, which decouples thickness and distance between electrodes, further improves timing performance and radiation hardness of the detector. We developed a simulation software - RASER (RAdiation SEmiconductoR) to simulate the time resolution of planar and 3D 4H-SiC detectors with different parameters and structures, and the reliability of the software is verified by comparing time resolution results of simulation with data. The rough time resolution of 3D 4H-SiC detector was estimated, and the simulation parameters could be used as guideline to 3D 4H-SiC detector design and optimization.