Source author record

X. Defay

X. Defay appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2021arXiv

Performance of a Large Area Photon Detector For Rare Event Search Applications

We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a $45.6$ $\mathrm{cm}^2$ surface area by 1-mm-thick $10.6$ $\mathrm{g}$ Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors (QETs) with superconducting critical temperature $T_c=41.5$ $\mathrm{mK}$ to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated with a collimated $^{55}$Fe X-ray source incident on the center of the detector. The noise equivalent power is measured to be $1\times 10^{-17}$ $\mathrm{W}/\sqrt{\mathrm{Hz}}$ in a bandwidth of $2.7$ $\mathrm{kHz}$. The baseline energy resolution is measured to be $σ_E = 3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.23}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$ (RMS). The detector also has an expected timing resolution of $σ_t = 2.3$ $μ\mathrm{s}$ for $5$ $σ_E$ events.

preprint2020arXiv

Description of CRESST-III Data

In CRESST-III, 10 cryogenic detector modules optimized for low energy thresholds were operated for almost two years (May 2016 - February 2018). Together with this document we are publishing data from the best performing detector module which has a nuclear recoil threshold of 30.1eV. With this data-set we were able to set limits on the cross-section for spin-dependent and spin-independent elastic scattering of dark matter particles off nuclei at dark matter masses down to 160MeV/c$^2$. We publish the energies of all events after data selection as well as of all events within the acceptance region for dark-matter searches. In this document we describe how to use these data sets.

preprint2019arXiv

First results on sub-GeV spin-dependent dark matter interactions with $^{7}$Li

In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.

preprint2016arXiv

Cryogenic silicon detectors with implanted contacts for the detection of visible photons using the Neganov-Luke Effect

There is a common need in astroparticle experiments such as direct dark matter detection, 0ν\b{eta}\b{eta} (double beta decay without emission of neutrinos) and Coherent Neutrino Nucleus Scattering experiments for light detectors with a very low energy threshold. By employing the Neganov-Luke Effect, the thermal signal of particle interactions in a semiconductor absorber operated at cryogenic temperatures, can be amplified by drifting the photogenerated electrons and holes in an electric field. This technology is not used in current experiments, in particular because of a reduction of the signal amplitude with time which is due to trapping of the charges within the absorber. We present here the first results of a novel type of Neganov-Luke Effect detector with an electric field configuration designed to improve the charge collection within the semiconductor.

preprint2016arXiv

Limits on momentum-dependent asymmetric dark matter with CRESST-II

The usual assumption in direct dark matter searches is to only consider the spin-dependent or spin-independent scattering of dark matter particles. However, especially in models with light dark matter particles $\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the momentum transfer $q^2$ can become dominant. One such model based on asymmetric dark matter has been invoked to overcome discrepancies in helioseismology and an indication was found for a particle with preferred mass of 3 $\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data from the CRESST-II experiment, which uses cryogenic detectors based on $\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter particles, are used to constrain these momentum-dependent models. The low energy threshold of 307 eV for nuclear recoils of the detector used, allows us to rule out the proposed best fit value above.

preprint2016arXiv

New Limits on Double Electron Capture of $^{40}$Ca and $^{180}$W

We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Depending on the process, these values improve the currently best limits by a factor of $\sim$1.4-30.

preprint2016arXiv

Results on light dark matter particles with a low-threshold CRESST-II detector

The CRESST-II experiment uses cryogenic detectors to search for nuclear recoil events induced by the elastic scattering of dark matter particles in CaWO$_4$ crystals. Given the low energy threshold of our detectors in combination with light target nuclei, low mass dark matter particles can be probed with high sensitivity. In this letter we present the results from data of a single detector module corresponding to 52 kg live days. A blind analysis is carried out. With an energy threshold for nuclear recoils of 307 eV we substantially enhance the sensitivity for light dark matter. Thereby, we extend the reach of direct dark matter experiments to the sub-region and demonstrate that the energy threshold is the key parameter in the search for low mass dark matter particles.

preprint2015arXiv

The CRESST Dark Matter Search - Status and Perspectives

In the past years the spotlight of the search for dark matter particles widened to the low mass region, both from theoretical and experimental side. We discuss results from data obtained in 2013 with a single detector TUM40. This detector is equipped with a new upgraded holding scheme to efficiently veto backgrounds induced by surface alpha decays. This veto, the low threshold of 0.6keV and an unprecedented background level for CaWO$_4$ target crystals render TUM40 the detector with the best overall performance of CRESST-II phase 2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate light dark matter particles (<3GeV/c$^2$), previously not accessible for other direct detection experiments.

preprint2011arXiv

Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments

The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.

preprint2011arXiv

Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes

The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.

preprint2010arXiv

A detection system to measure muon-induced neutrons for direct Dark Matter searches

Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.

preprint2010arXiv

Monitoring of the thermal neutron flux in the LSM underground laboratory

This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$π$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $Φ_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.

preprint2009arXiv

A new high-background-rejection dark matter Ge cryogenic detector

A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $β$, approaching 10$^5$ . This opens the road to investigate the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.

preprint2009arXiv

First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.