Researcher profile

Wilfried Glastre

Wilfried Glastre contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
6works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2012arXiv

Acousto-optic laser optical feedback imaging

We present a photon noise and diffraction limited imaging method combining the imaging laser and ultrasonic waves. The laser optical feedback imaging (LOFI) technique is an ultrasensitive imaging method for imaging objects through or embedded within a scattering medium. However, LOFI performances are dramatically limited by parasitic optical feedback occurring in the experimental setup. In this work, we have tagged the ballistic photons by an acousto-optic effect in order to filter the parasitic feedback effect and to reach the theoretical and ultimate sensitivity of the LOFI technique. We present the principle and the experimental setup of the acousto-optic laser optical feedback imaging (AO-LOFI) technique, and we demonstrate the suppression of the parasitic feedback.

preprint2012arXiv

Deep and optically resolved imaging through scattering media by space-reversed propagation

We propose a novel technique of microscopy to overcome the effects of both scattering and limitation of the accessible depth due to the objective working distance. By combining Laser Optical Feedback Imaging (LOFI) with Acoustic Photon Taging (APT) and Synthetic Aperture (SA) refocusing we demonstrate an ultimate shot noise sensitivity at low power (required to preserve the tissues) and a high resolution beyond the microscope working distance. More precisely, with a laser power of 10mW, we obtain images with a micrometric resolution over ~8 transport mean free paths, corresponding to 1.3 times the microscope working distance. Various applications such as biomedical diagnosis, research and development of new drugs and therapies can benefit from our imaging setup.

preprint2012arXiv

Experimental comparison of autodyne and heterodyne laser interferometry using a Nd:YVO4 microchip laser

Using a Nd:YVO4 microchip laser with a relaxation frequency in the megahertz range, we have experimentally compared a heterodyne interferometer based on a Michelson configuration with an autodyne interferometer based on the laser optical feedback imaging (LOFI) method regarding their signal to noise ratios. In the heterodyne configuration, the beating between the reference beam and the signal beam is realized outside the laser cavity while in the autodyne configuration, the wave beating takes place inside the laser cavity and the relaxation oscillations of the laser intensity then play an important part. For a given laser output power, object under investigation and detection noise level, we have determined the amplification gain of the LOFI interferometer compared to the heterodyne interferometer. LOFI interferometry is demonstrated to show higher performances than heterodyne interferometry for a wide range of laser power and detection level of noise. The experimental results are in good agreement with the theoretical predictions.

preprint2012arXiv

Limitations of synthetic aperture laser optical feedback imaging

In this paper we study the origin and the effect of amplitude and phase noise on Laser Optical Feedback Imaging (LOFI) associated with Synthetic Aperture (SA) imaging system. Amplitude noise corresponds to photon noise and acts as an additive noise, it can be reduced by increasing the global measurement time. Phase noise can be divided in three families: random, sinusoidal and drift phase noise; we show that it acts as a multiplicative noise. We explain how we can reduce phase noise by making oversampling or multiple measurements depending on its type. This work can easily be extended to all SA systems (Radar, Laser or Terahertz), especially when raw holograms are acquired point by point.

preprint2012arXiv

Sensitivity of synthetic aperture laser optical feedback imaging

In this paper we compare the sensitivity of two imaging configurations both based on Laser Optical Feedback Imaging (LOFI). The first one is direct imaging, which uses conventional optical focalisation on target and the second one is made by Synthetic Aperture (SA) Laser, which uses numerical focalisation. We show that SA configuration allows to obtain good resolutions with high working distance and that the drawback of SA imagery is that it has a worse photometric balance in comparison to conventional microscope. This drawback is partially compensated by the important sensitivity of LOFI. Another interest of SA relies on the capacity of getting a 3D information in a single x-y scan.

preprint2012arXiv

Synthetic aperture laser optical feedback imaging using a translational scanning with galvanometric mirrors

In this paper we present an experimental setup based on Laser Optical Feedback Imaging (LOFI) and on Synthetic Aperture (SA) with translational scanning by galvanometric mirrors for the purpose of making deep and resolved images through scattering media. We provide real 2D optical synthetic-aperture image of a fixed scattering target with a moving aperture and an isotropic resolution. We demonstrate theoretically and experimentally that we can keep microscope resolution beyond the working distance. A photometric balance is made and we show that the number of photons participating in the final image decreases with the square of the reconstruction distance. This degradation is partially compensated by the high sensitivity of LOFI.