Source author record

Hugues Guillet de Chatellus

Hugues Guillet de Chatellus appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2020arXiv

Toward a large bandwidth photonic correlator for infrared heterodyne interferometry

Infrared heterodyne interferometry has been proposed as a practical alternative for recombining a large number of telescopes over kilometric baselines in the mid-infrared. However, the current limited correlation capacities impose strong restrictions on the sensitivity of this appealing technique. In this paper, we propose to address the problem of transport and correlation of wide-bandwidth signals over kilometric distances by introducing photonic processing in infrared heterodyne interferometry. We describe the architecture of a photonic double-sideband correlator for two telescopes, along with the experimental demonstration of this concept on a proof-of-principle test bed. We demonstrate the \textit{a posteriori} correlation of two infrared signals previously generated on a two-telescope simulator in a double-sideband photonic correlator. A degradation of the signal-to-noise ratio of $13\%$, equivalent to a noise factor $\text{NF}=1.15$, is obtained through the correlator, and the temporal coherence properties of our input signals are retrieved from these measurements. Our results demonstrate that photonic processing can be used to correlate heterodyne signals with a potentially large increase of detection bandwidth. These developments open the way to photonic processing of wide bandwidth signals for mid-infrared heterodyne interferometry, in particular for a large number of telescopes and for direct imager recombiners.

preprint2014arXiv

Comparative study of autodyne and heterodyne laser interferometry for imaging

For given laser output power, object under investigation and photodiode noise level, we have theoretically compared the signal to noise ratio (SNR) of a heterodyne scanning imager based on a Michelson interferometer and of an autodyne setup based on the Laser Optical Feedback Imaging (LOFI) technique. In both cases, the image is obtained point by point. In the heterodyne configuration, the beating between the reference beam and the signal beam is realized outside the laser cavity (i.e. directly on the detector), while in the autodyne configuration, the wave beating takes place inside the laser cavity and therefore is indirectly detected. In the autodyne configuration, where the laser relaxation oscillations play a leading role, we have compared 1D scans obtained by numerical simulations with different lasers dynamical parameters. Finally we have determined the best laser for LOFI applications and the experimental conditions for which the LOFI detection setup (autodyne interferometer) is competitive comparing to a heterodyne interferometer.

preprint2014arXiv

Time-resolved and spectral-resolved optical imaging to study brain hemodynamics in songbirds

Contrary to the intense debate about brain oxygen dynamics and its uncoupling in mammals, very little is known in birds. In zebra finches, picosecond optical tomography (POT) with a white laser and a streak camera can measure in vivo oxy-hemoglobin (HbO2) and deoxy-hemoglobin (Hb) concentration changes following physiological stimulation (familiar calls and songs). POT demonstrated sufficient sub-micromolar sensitivity to resolve the fast changes in hippocampus and auditory forebrain areas with 250 μm resolution. The time-course is composed of (i) an early 2s-long event with a significant decrease in Hb and HbO2, respectively -0.7 μMoles/L and -0.9 μMoles/L (ii) a subsequent increase in blood oxygen availability with a plateau of HbO2 (+0.3 μMoles/L) and (iii) pronounced vasodilatation events immediately following the end of the stimulus. One of the findings of our work is the direct link between the blood oxygen level-dependent (BOLD) signals previously published in birds and our results. Furthermore, the early vasoconstriction event and post-stimulus ringing seem to be more pronounced in birds than in mammals. These results in bird, a tachymetabolic vertebrate with a long lifespan, can potentially yield new insights for example in brain aging.

preprint2012arXiv

Acousto-optic laser optical feedback imaging

We present a photon noise and diffraction limited imaging method combining the imaging laser and ultrasonic waves. The laser optical feedback imaging (LOFI) technique is an ultrasensitive imaging method for imaging objects through or embedded within a scattering medium. However, LOFI performances are dramatically limited by parasitic optical feedback occurring in the experimental setup. In this work, we have tagged the ballistic photons by an acousto-optic effect in order to filter the parasitic feedback effect and to reach the theoretical and ultimate sensitivity of the LOFI technique. We present the principle and the experimental setup of the acousto-optic laser optical feedback imaging (AO-LOFI) technique, and we demonstrate the suppression of the parasitic feedback.

preprint2012arXiv

Coherent microscopy by laser optical feedback imaging (LOFI) technique

The application of the non conventional imaging technique LOFI (Laser Optical Feedback Imaging) to coherent microscopy is presented. This simple and efficient technique using frequency-shifted optical feedback needs the sample to be scanned in order to obtain an image. The effects on magnitude and phase signals such as vignetting and field curvature occasioned by the scanning with galvanometric mirrors are discussed. A simple monitoring method based on phase images is proposed to find the optimal position of the scanner. Finally, some experimental results illustrating this technique are presented.

preprint2012arXiv

Deep and optically resolved imaging through scattering media by space-reversed propagation

We propose a novel technique of microscopy to overcome the effects of both scattering and limitation of the accessible depth due to the objective working distance. By combining Laser Optical Feedback Imaging (LOFI) with Acoustic Photon Taging (APT) and Synthetic Aperture (SA) refocusing we demonstrate an ultimate shot noise sensitivity at low power (required to preserve the tissues) and a high resolution beyond the microscope working distance. More precisely, with a laser power of 10mW, we obtain images with a micrometric resolution over ~8 transport mean free paths, corresponding to 1.3 times the microscope working distance. Various applications such as biomedical diagnosis, research and development of new drugs and therapies can benefit from our imaging setup.

preprint2012arXiv

Experimental comparison of autodyne and heterodyne laser interferometry using a Nd:YVO4 microchip laser

Using a Nd:YVO4 microchip laser with a relaxation frequency in the megahertz range, we have experimentally compared a heterodyne interferometer based on a Michelson configuration with an autodyne interferometer based on the laser optical feedback imaging (LOFI) method regarding their signal to noise ratios. In the heterodyne configuration, the beating between the reference beam and the signal beam is realized outside the laser cavity while in the autodyne configuration, the wave beating takes place inside the laser cavity and the relaxation oscillations of the laser intensity then play an important part. For a given laser output power, object under investigation and detection noise level, we have determined the amplification gain of the LOFI interferometer compared to the heterodyne interferometer. LOFI interferometry is demonstrated to show higher performances than heterodyne interferometry for a wide range of laser power and detection level of noise. The experimental results are in good agreement with the theoretical predictions.

preprint2012arXiv

Limitations of synthetic aperture laser optical feedback imaging

In this paper we study the origin and the effect of amplitude and phase noise on Laser Optical Feedback Imaging (LOFI) associated with Synthetic Aperture (SA) imaging system. Amplitude noise corresponds to photon noise and acts as an additive noise, it can be reduced by increasing the global measurement time. Phase noise can be divided in three families: random, sinusoidal and drift phase noise; we show that it acts as a multiplicative noise. We explain how we can reduce phase noise by making oversampling or multiple measurements depending on its type. This work can easily be extended to all SA systems (Radar, Laser or Terahertz), especially when raw holograms are acquired point by point.

preprint2012arXiv

Sensitivity of synthetic aperture laser optical feedback imaging

In this paper we compare the sensitivity of two imaging configurations both based on Laser Optical Feedback Imaging (LOFI). The first one is direct imaging, which uses conventional optical focalisation on target and the second one is made by Synthetic Aperture (SA) Laser, which uses numerical focalisation. We show that SA configuration allows to obtain good resolutions with high working distance and that the drawback of SA imagery is that it has a worse photometric balance in comparison to conventional microscope. This drawback is partially compensated by the important sensitivity of LOFI. Another interest of SA relies on the capacity of getting a 3D information in a single x-y scan.

preprint2012arXiv

Synthetic aperture laser optical feedback imaging using a translational scanning with galvanometric mirrors

In this paper we present an experimental setup based on Laser Optical Feedback Imaging (LOFI) and on Synthetic Aperture (SA) with translational scanning by galvanometric mirrors for the purpose of making deep and resolved images through scattering media. We provide real 2D optical synthetic-aperture image of a fixed scattering target with a moving aperture and an isotropic resolution. We demonstrate theoretically and experimentally that we can keep microscope resolution beyond the working distance. A photometric balance is made and we show that the number of photons participating in the final image decreases with the square of the reconstruction distance. This degradation is partially compensated by the high sensitivity of LOFI.