Source author record

Wenyun Ju

Wenyun Ju appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Real-Time Monitoring of Area Angles with Synchrophasor Measurements

This paper develops a comprehensive framework of Area Angle Monitoring (AAM) to monitor the stress of bulk power transfer across an area of a power transmission system in real-time. Area angle is calculated from synchrophasor measurements to provide alert to system operators if the area angle exceeds pre-defined thresholds. This paper proposes general methods to identify these warning and emergency thresholds, and tests a mitigation strategy to relieve the area stress when the area angle exceeds the threshold. In order to handle the limited coverage of synchrophasor measurements, this paper proposes methods to estimate phase angles for boundary buses without synchrophasor measurements, which extends the application of AAM. AAM is verified for a power transmission area in the Western Electricity Coordinating Council system with both simulated data and synchrophasor measurements recorded from real events. A utility deployment to test the framework for monitoring area angle with live-stream and recorded synchrophasor data is described.

preprint2016arXiv

Estimating the Propagation of Interdependent Cascading Outages with Multi-Type Branching Processes

In this paper, the multi-type branching process is applied to describe the statistics and interdependencies of line outages, the load shed, and isolated buses. The offspring mean matrix of the multi-type branching process is estimated by the Expectation Maximization (EM) algorithm and can quantify the extent of outage propagation. The joint distribution of two types of outages is estimated by the multi-type branching process via the Lagrange-Good inversion. The proposed model is tested with data generated by the AC OPA cascading simulations on the IEEE 118-bus system. The largest eigenvalues of the offspring mean matrix indicate that the system is closer to criticality when considering the interdependence of different types of outages. Compared with empirically estimating the joint distribution of the total outages, good estimate is obtained by using the multitype branching process with a much smaller number of cascades, thus greatly improving the efficiency. It is shown that the multitype branching process can effectively predict the distribution of the load shed and isolated buses and their conditional largest possible total outages even when there are no data of them.