Source author record

Ian Dobson

Ian Dobson appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2025arXiv

The statistical spread of transmission outages on a fast protection time scale based on utility data

When there is a fault, the protection system automatically removes one or more transmission lines on a fast time scale of less than one minute. The outaged lines form a pattern in the transmission network. We extract these patterns from utility outage data, determine some key statistics of these patterns, and then show how to generate new patterns consistent with these statistics. The generated patterns provide a new and easily feasible way to model the overall effect of the protection system at the scale of a large transmission system. This new generative modeling of protection is expected to contribute to simulations of disturbances in large grids so that they can better quantify the risk of blackouts. Analysis of the pattern sizes suggests an index that describes how much outages spread in the transmission network at the fast timescale.

preprint2020arXiv

Bayesian estimates of transmission line outage rates that consider line dependencies

Transmission line outage rates are fundamental to power system reliability analysis. Line outages are infrequent, occurring only about once a year, so outage data are limited. We propose a Bayesian hierarchical model that leverages line dependencies to better estimate outage rates of individual transmission lines from limited outage data. The Bayesian estimates have a lower standard deviation than estimating the outage rates simply by dividing the number of outages by the number of years of data, especially when the number of outages is small. The Bayesian model produces more accurate individual line outage rates, as well as estimates of the uncertainty of these rates. Better estimates of line outage rates can improve system risk assessment, outage prediction, and maintenance scheduling.

preprint2020arXiv

Real-Time Monitoring of Area Angles with Synchrophasor Measurements

This paper develops a comprehensive framework of Area Angle Monitoring (AAM) to monitor the stress of bulk power transfer across an area of a power transmission system in real-time. Area angle is calculated from synchrophasor measurements to provide alert to system operators if the area angle exceeds pre-defined thresholds. This paper proposes general methods to identify these warning and emergency thresholds, and tests a mitigation strategy to relieve the area stress when the area angle exceeds the threshold. In order to handle the limited coverage of synchrophasor measurements, this paper proposes methods to estimate phase angles for boundary buses without synchrophasor measurements, which extends the application of AAM. AAM is verified for a power transmission area in the Western Electricity Coordinating Council system with both simulated data and synchrophasor measurements recorded from real events. A utility deployment to test the framework for monitoring area angle with live-stream and recorded synchrophasor data is described.

preprint2016arXiv

Obtaining statistics of cascading line outages spreading in an electric transmission network from standard utility data

We show how to use standard transmission line outage historical data to obtain the network topology in such a way that cascades of line outages can be easily located on the network. Then we obtain statistics quantifying how cascading outages typically spread on the network. Processing real outage data is fundamental for understanding cascading and for evaluating the validity of the many different models and simulations that have been proposed for cascading in power networks.

preprint2015arXiv

Applying a formula for generator redispatch to damp interarea oscillations using synchrophasors

If an interarea oscillatory mode has insufficient damping, generator redispatch can be used to improve its damping. We explain and apply a new analytic formula for the modal sensitivity to rank the best pairs of generators to redispatch. The formula requires some dynamic power system data and we show how to obtain that data from synchrophasor measurements. The application of the formula to damp interarea modes is explained and illustrated with interarea modes of the New England 10-machine power system.

preprint2014arXiv

Monitoring voltage collapse margin by measuring the area voltage across several transmission lines with synchrophasors

We consider the fast monitoring of voltage collapse margin using synchrophasor measurements at both ends of transmission lines that transfer power from two generators to two loads. This shows a way to extend the monitoring of a radial transmission line to multiple transmission lines. The synchrophasor voltages are combined into a single complex voltage difference across an area containing the transmission lines that can be monitored in the same way as a single transmission line. We identify ideal conditions under which this reduction to the single line case perfectly preserves the margin to voltage collapse, and give an example that shows that the error under practical non-ideal conditions is reasonably small.

preprint2014arXiv

Monitoring voltage collapse margin with synchrophasors across transmission corridors with multiple lines and multiple contingencies

We use synchrophasor measurements of the complex voltage and current at both ends of multiple transmission lines that connect areas of a power system to monitor the online voltage collapse margin. A new reduction is used to reduce the multiple transmission lines to a single line equivalent and determine how to combine the synchrophasor measurements. Generator reactive power limits can be accommodated. The results show that this methodology can capture the effect of multiple contingencies inside the transmission corridors, giving awareness to the operators about the severity of contingencies with respect to voltage stability.

preprint2014arXiv

Synchrophasor monitoring of single line outages via area angle and susceptance

The area angle is a scalar measure of power system area stress that responds to line outages within the area and is a combination of synchrophasor measurements of voltage angles around the border of the area. Both idealized and practical examples are given to show that the variation of the area angle for single line outages can be approximately related to changes in the overall susceptance of the area and the line outage severity.

preprint2014arXiv

Threshold-based monitoring of cascading outages with PMU measurements of area angle

When power grids are heavily stressed with a bulk power transfer, it is useful to have a fast indication of the increased stress when multiple line outages occur. Reducing the bulk power transfer when the outages are severe could forestall further cascading of the outages. We show that synchrophasor measurements of voltage angles at all the area tie lines can be used to indicate the severity of multiple outages. These synchrophasor measurements are readily combined into an "area angle" that can quickly track the severity of multiple outages after they occur. We present a procedure to define thresholds for the area angle that relate to the maximum power that can be transferred through the area until a line limit is reached. Then in real time we would monitor the area angle and compare it to the thresholds when line outages occur to determine the urgency (or not) of actions to reduce the bulk transfer of power through the area. The procedure also identifies exceptional cases in which separate actions to resolve local power distribution problems are needed. We illustrate the thresholds and monitoring with the area angle across several states of Northwestern USA.

preprint2013arXiv

Transdisciplinary electric power grid science

The 20th-century engineering feat that most improved the quality of human life, the electric power system, now faces discipline-spanning challenges that threaten that distinction. So multilayered and complex that they resemble ecosystems, power grids face risks from their interdependent cyber, physical, social and economic layers. Only with a holistic understanding of the dynamics of electricity infrastructure and human operators, automatic controls, electricity markets, weather, climate and policy can we fortify worldwide access to electricity.