Source author record

Wen-Qian Huang

Wen-Qian Huang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

Study of a sealed high gas pressure THGEM detector and response of Alpha particle spectra

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under high pressure of 2 atm mainly consist in selecting optimal voltages for ionization region and induction region. The dependence of the shape of Alpha particle spectra measured with relative gas gain on gas pressure (1.3 $\sim$ 2.0 atm) has been studied. The 8 groups of relative gas gain versus working voltage of THGEM expressed by weighting filed $E/P$ are normalized, being consistent with theory. The results show that the air tightness of the chamber is good measured by a sensitive barometer and checked with gas gain. The experimental results are compared with Monte Carlo simulation on energy deposition without gas gain involved.

preprint2015arXiv

A Novel Method of Encoded Multiplexing Readout for Micro-pattern Gas Detectors

The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a particle, a novel method of encoded multiplexing readout for MPGDs is presented in this paper. The method offers a feasible and easily-extensible way of encoding and decoding, and can significantly reduce the number of readout channels. A verification test was carried out on a 5*5 cm2 Thick Gas Electron Multiplier (THGEM) detector using a 8 keV Cu X-ray source with 100um slit, where 166 strips are read out by 21 encoded readout channels. The test results show a good linearity in its position response, and the spatial resolution root-mean-square (RMS) of the test system is about 260 μm. This method has an attractive potential to build large area detectors and can be easily adapted to other detectors like MPGDs.