Researcher profile

Weimin Zhou

Weimin Zhou contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
10topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2022arXiv

A deep Q-learning method for optimizing visual search strategies in backgrounds of dynamic noise

Humans process visual information with varying resolution (foveated visual system) and explore images by orienting through eye movements the high-resolution fovea to points of interest. The Bayesian ideal searcher (IS) that employs complete knowledge of task-relevant information optimizes eye movement strategy and achieves the optimal search performance. The IS can be employed as an important tool to evaluate the optimality of human eye movements, and potentially provide guidance to improve human observer visual search strategies. Najemnik and Geisler (2005) derived an IS for backgrounds of spatial 1/f noise. The corresponding template responses follow Gaussian distributions and the optimal search strategy can be analytically determined. However, the computation of the IS can be intractable when considering more realistic and complex backgrounds such as medical images. Modern reinforcement learning methods, successfully applied to obtain optimal policy for a variety of tasks, do not require complete knowledge of the background generating functions and can be potentially applied to anatomical backgrounds. An important first step is to validate the optimality of the reinforcement learning method. In this study, we investigate the ability of a reinforcement learning method that employs Q-network to approximate the IS. We demonstrate that the search strategy corresponding to the Q-network is consistent with the IS search strategy. The findings show the potential of the reinforcement learning with Q-network approach to estimate optimal eye movement planning with real anatomical backgrounds.

preprint2022arXiv

Learning stochastic object models from medical imaging measurements by use of advanced ambient generative adversarial networks

Purpose: To objectively assess new medical imaging technologies via computer-simulations, it is important to account for the variability in the ensemble of objects to be imaged. This source of variability can be described by stochastic object models (SOMs). It is generally desirable to establish SOMs from experimental imaging measurements acquired by use of a well-characterized imaging system, but this task has remained challenging. Approach: A generative adversarial network (GAN)-based method that employs AmbientGANs with modern progressive or multiresolution training approaches is proposed. AmbientGANs established using the proposed training procedure are systematically validated in a controlled way using computer-simulated magnetic resonance imaging (MRI) data corresponding to a stylized imaging system. Emulated single-coil experimental MRI data are also employed to demonstrate the methods under less stylized conditions. Results: The proposed AmbientGAN method can generate clean images when the imaging measurements are contaminated by measurement noise. When the imaging measurement data are incomplete, the proposed AmbientGAN can reliably learn the distribution of the measurement components of the objects. Conclusions: Both visual examinations and quantitative analyses, including task-specific validations using the Hotelling observer, demonstrated that the proposed AmbientGAN method holds promise to establish realistic SOMs from imaging measurements.

preprint2021arXiv

Advancing the AmbientGAN for learning stochastic object models

Medical imaging systems are commonly assessed and optimized by use of objective-measures of image quality (IQ) that quantify the performance of an observer at specific tasks. Variation in the objects to-be-imaged is an important source of variability that can significantly limit observer performance. This object variability can be described by stochastic object models (SOMs). In order to establish SOMs that can accurately model realistic object variability, it is desirable to use experimental data. To achieve this, an augmented generative adversarial network (GAN) architecture called AmbientGAN has been developed and investigated. However, AmbientGANs cannot be immediately trained by use of advanced GAN training methods such as the progressive growing of GANs (ProGANs). Therefore, the ability of AmbientGANs to establish realistic object models is limited. To circumvent this, a progressively-growing AmbientGAN (ProAmGAN) has been proposed. However, ProAmGANs are designed for generating two-dimensional (2D) images while medical imaging modalities are commonly employed for imaging three-dimensional (3D) objects. Moreover, ProAmGANs that employ traditional generator architectures lack the ability to control specific image features such as fine-scale textures that are frequently considered when optimizing imaging systems. In this study, we address these limitations by proposing two advanced AmbientGAN architectures: 3D ProAmGANs and Style-AmbientGANs (StyAmGANs). Stylized numerical studies involving magnetic resonance (MR) imaging systems are conducted. The ability of 3D ProAmGANs to learn 3D SOMs from imaging measurements and the ability of StyAmGANs to control fine-scale textures of synthesized objects are demonstrated.

preprint2020arXiv

A signal detection model for quantifying over-regularization in non-linear image reconstruction

Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regularization in the sense that they can favor removal of subtle details in the image. To address this shortcoming, we develop an image quality metric based on signal detection that serves as a surrogate to the qualitative loss of fine image details. Methods: The metric is demonstrated in the context of a breast CT simulation, where different equal-dose configurations are considered. The configurations differ in the number of projections acquired. Image reconstruction is performed with a non-linear algorithm based on total variation constrained least-squares (TV-LSQ). The images are evaluated visually, with image RMSE, and with the proposed signal-detection based metric. The latter uses a small signal, and computes detectability in the sinogram and in the reconstructed image. Loss of signal detectability through the image reconstruction process is taken as a quantitative measure of loss of fine details in the image. Results: Loss of signal detectability is seen to correlate well with the blocky or patchy appearance due to over-regularization with TV-LSQ, and this trend runs counter to the image RMSE metric, which tends to favor the over-regularized images. Conclusions: The proposed signal detection based metric provides an image quality assessment that is complimentary to that of image RMSE. Using the two metrics in concert may yield a useful prescription for determining CT algorithm and configuration parameters when non-linear image reconstruction is used.

preprint2020arXiv

Approximating the Ideal Observer for joint signal detection and localization tasks by use of supervised learning methods

Medical imaging systems are commonly assessed and optimized by use of objective measures of image quality (IQ). The Ideal Observer (IO) performance has been advocated to provide a figure-of-merit for use in assessing and optimizing imaging systems because the IO sets an upper performance limit among all observers. When joint signal detection and localization tasks are considered, the IO that employs a modified generalized likelihood ratio test maximizes observer performance as characterized by the localization receiver operating characteristic (LROC) curve. Computations of likelihood ratios are analytically intractable in the majority of cases. Therefore, sampling-based methods that employ Markov-Chain Monte Carlo (MCMC) techniques have been developed to approximate the likelihood ratios. However, the applications of MCMC methods have been limited to relatively simple object models. Supervised learning-based methods that employ convolutional neural networks have been recently developed to approximate the IO for binary signal detection tasks. In this paper, the ability of supervised learning-based methods to approximate the IO for joint signal detection and localization tasks is explored. Both background-known-exactly and background-known-statistically signal detection and localization tasks are considered. The considered object models include a lumpy object model and a clustered lumpy model, and the considered measurement noise models include Laplacian noise, Gaussian noise, and mixed Poisson-Gaussian noise. The LROC curves produced by the supervised learning-based method are compared to those produced by the MCMC approach or analytical computation when feasible. The potential utility of the proposed method for computing objective measures of IQ for optimizing imaging system performance is explored.

preprint2020arXiv

Learning Numerical Observers using Unsupervised Domain Adaptation

Medical imaging systems are commonly assessed by use of objective image quality measures. Supervised deep learning methods have been investigated to implement numerical observers for task-based image quality assessment. However, labeling large amounts of experimental data to train deep neural networks is tedious, expensive, and prone to subjective errors. Computer-simulated image data can potentially be employed to circumvent these issues; however, it is often difficult to computationally model complicated anatomical structures, noise sources, and the response of real world imaging systems. Hence, simulated image data will generally possess physical and statistical differences from the experimental image data they seek to emulate. Within the context of machine learning, these differences between the sets of two images is referred to as domain shift. In this study, we propose and investigate the use of an adversarial domain adaptation method to mitigate the deleterious effects of domain shift between simulated and experimental image data for deep learning-based numerical observers (DL-NOs) that are trained on simulated images but applied to experimental ones. In the proposed method, a DL-NO will initially be trained on computer-simulated image data and subsequently adapted for use with experimental image data, without the need for any labeled experimental images. As a proof of concept, a binary signal detection task is considered. The success of this strategy as a function of the degree of domain shift present between the simulated and experimental image data is investigated.

preprint2020arXiv

Learning stochastic object models from medical imaging measurements using Progressively-Growing AmbientGANs

It has been advocated that medical imaging systems and reconstruction algorithms should be assessed and optimized by use of objective measures of image quality that quantify the performance of an observer at specific diagnostic tasks. One important source of variability that can significantly limit observer performance is variation in the objects to-be-imaged. This source of variability can be described by stochastic object models (SOMs). A SOM is a generative model that can be employed to establish an ensemble of to-be-imaged objects with prescribed statistical properties. In order to accurately model variations in anatomical structures and object textures, it is desirable to establish SOMs from experimental imaging measurements acquired by use of a well-characterized imaging system. Deep generative neural networks, such as generative adversarial networks (GANs) hold great potential for this task. However, conventional GANs are typically trained by use of reconstructed images that are influenced by the effects of measurement noise and the reconstruction process. To circumvent this, an AmbientGAN has been proposed that augments a GAN with a measurement operator. However, the original AmbientGAN could not immediately benefit from modern training procedures, such as progressive growing, which limited its ability to be applied to realistically sized medical image data. To circumvent this, in this work, a new Progressive Growing AmbientGAN (ProAmGAN) strategy is developed for establishing SOMs from medical imaging measurements. Stylized numerical studies corresponding to common medical imaging modalities are conducted to demonstrate and validate the proposed method for establishing SOMs.

preprint2020arXiv

Markov-Chain Monte Carlo Approximation of the Ideal Observer using Generative Adversarial Networks

The Ideal Observer (IO) performance has been advocated when optimizing medical imaging systems for signal detection tasks. However, analytical computation of the IO test statistic is generally intractable. To approximate the IO test statistic, sampling-based methods that employ Markov-Chain Monte Carlo (MCMC) techniques have been developed. However, current applications of MCMC techniques have been limited to several object models such as a lumpy object model and a binary texture model, and it remains unclear how MCMC methods can be implemented with other more sophisticated object models. Deep learning methods that employ generative adversarial networks (GANs) hold great promise to learn stochastic object models (SOMs) from image data. In this study, we described a method to approximate the IO by applying MCMC techniques to SOMs learned by use of GANs. The proposed method can be employed with arbitrary object models that can be learned by use of GANs, thereby the domain of applicability of MCMC techniques for approximating the IO performance is extended. In this study, both signal-known-exactly (SKE) and signal-known-statistically (SKS) binary signal detection tasks are considered. The IO performance computed by the proposed method is compared to that computed by the conventional MCMC method. The advantages of the proposed method are discussed.

preprint2020arXiv

Medical image reconstruction with image-adaptive priors learned by use of generative adversarial networks

Medical image reconstruction is typically an ill-posed inverse problem. In order to address such ill-posed problems, the prior distribution of the sought after object property is usually incorporated by means of some sparsity-promoting regularization. Recently, prior distributions for images estimated using generative adversarial networks (GANs) have shown great promise in regularizing some of these image reconstruction problems. In this work, we apply an image-adaptive GAN-based reconstruction method (IAGAN) to reconstruct high fidelity images from incomplete medical imaging data. It is observed that the IAGAN method can potentially recover fine structures in the object that are relevant for medical diagnosis but may be oversmoothed in reconstructions with traditional sparsity-promoting regularization.

preprint2020arXiv

Progressively-Growing AmbientGANs For Learning Stochastic Object Models From Imaging Measurements

The objective optimization of medical imaging systems requires full characterization of all sources of randomness in the measured data, which includes the variability within the ensemble of objects to-be-imaged. This can be accomplished by establishing a stochastic object model (SOM) that describes the variability in the class of objects to-be-imaged. Generative adversarial networks (GANs) can be potentially useful to establish SOMs because they hold great promise to learn generative models that describe the variability within an ensemble of training data. However, because medical imaging systems record imaging measurements that are noisy and indirect representations of object properties, GANs cannot be directly applied to establish stochastic models of objects to-be-imaged. To address this issue, an augmented GAN architecture named AmbientGAN was developed to establish SOMs from noisy and indirect measurement data. However, because the adversarial training can be unstable, the applicability of the AmbientGAN can be potentially limited. In this work, we propose a novel training strategy---Progressive Growing of AmbientGANs (ProAGAN)---to stabilize the training of AmbientGANs for establishing SOMs from noisy and indirect imaging measurements. An idealized magnetic resonance (MR) imaging system and clinical MR brain images are considered. The proposed methodology is evaluated by comparing signal detection performance computed by use of ProAGAN-generated synthetic images and images that depict the true object properties.

preprint2020arXiv

Strain controlled superconductivity in few-layer NbSe2

The controlled tunability of superconductivity in low-dimensional materials may enable new quantum devices. Particularly in triplet or topological superconductors, tunneling devices such as Josephson junctions etc. can demonstrate exotic functionalities. The tunnel barrier, an insulating or normal material layer separating two superconductors, is a key component for the junctions. Thin layers of NbSe2 have been shown as a superconductor with strong spin orbit coupling, which can give rise to topological superconductivity if driven by a large magnetic exchange field. Here we demonstrate the superconductor-insulator transitions in epitaxially grown few-layer NbSe2 with wafer-scale uniformity on insulating substrates. We provide the electrical transport, Raman spectroscopy, cross-sectional transmission electron microscopy, and X-ray diffraction characterizations of the insulating phase. We show that the superconductor-insulator transition is driven by strain, which also causes characteristic energy shifts of the Raman modes. Our observation paves the way for high quality hetero-junction tunnel barriers to be seamlessly built into epitaxial NbSe2 itself, thereby enabling highly scalable tunneling devices for superconductor-based quantum electronics.

preprint2020arXiv

Varied fusion reaction probability induced by ion stopping modification in laser-driven plasma with different temperature

The dynamics of nuclear reaction in plasma is a fundamental issue in many high energy density researches, such as the astrophysical reactions and the inertial confinement fusion. The effective reaction cross-sections and ion stopping power in plasma need to be taken into account to analyze the reactivity. In this research, we have experimentally investigated the from D-D reactions from interactions between deuteron beams and deuterated polystyrene (CD) plasma, driven by two laser pulses respectively. The neutron yields, plasma density and deuteron energy loss in plasma have been measured, and the plasma temperature and deuteron stopping power have been analyzed from simulations. It is shown that, compared with a cold target, the reaction probability in plasma conditions can be enhanced or suppressed, which is ascribed to the deuteron stopping power modifications in plasma. In hotter CD plasma, the energy loss of moderate energetic deuterons reduces, which leads to higher D-D reaction probability, while the contrary happens in colder plasma. This work provides new understanding of fusion reactions in plasma environment.