Researcher profile

Weihua Zhou

Weihua Zhou contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2021arXiv

A Deep Learning-Based Approach to Extracting Periosteal and Endosteal Contours of Proximal Femur in Quantitative CT Images

Automatic CT segmentation of proximal femur is crucial for the diagnosis and risk stratification of orthopedic diseases; however, current methods for the femur CT segmentation mainly rely on manual interactive segmentation, which is time-consuming and has limitations in both accuracy and reproducibility. In this study, we proposed an approach based on deep learning for the automatic extraction of the periosteal and endosteal contours of proximal femur in order to differentiate cortical and trabecular bone compartments. A three-dimensional (3D) end-to-end fully convolutional neural network, which can better combine the information between neighbor slices and get more accurate segmentation results, was developed for our segmentation task. 100 subjects aged from 50 to 87 years with 24,399 slices of proximal femur CT images were enrolled in this study. The separation of cortical and trabecular bone derived from the QCT software MIAF-Femur was used as the segmentation reference. We randomly divided the whole dataset into a training set with 85 subjects for 10-fold cross-validation and a test set with 15 subjects for evaluating the performance of models. Two models with the same network structures were trained and they achieved a dice similarity coefficient (DSC) of 97.87% and 96.49% for the periosteal and endosteal contours, respectively. To verify the excellent performance of our model for femoral segmentation, we measured the volume of different parts of the femur and compared it with the ground truth and the relative errors between predicted result and ground truth are all less than 5%. It demonstrated a strong potential for clinical use, including the hip fracture risk prediction and finite element analysis.

preprint2021arXiv

A Deep Learning-based Method to Extract Lumen and Media-Adventitia in Intravascular Ultrasound Images

Intravascular ultrasound (IVUS) imaging allows direct visualization of the coronary vessel wall and is suitable for the assessment of atherosclerosis and the degree of stenosis. Accurate segmentation and measurements of lumen and median-adventitia (MA) from IVUS are essential for such a successful clinical evaluation. However, current segmentation relies on manual operations, which is time-consuming and user-dependent. In this paper, we aim to develop a deep learning-based method using an encoder-decoder deep architecture to automatically extract both lumen and MA border. Our method named IVUS-U-Net++ is an extension of the well-known U-Net++ model. More specifically, a feature pyramid network was added to the U-Net++ model, enabling the utilization of feature maps at different scales. As a result, the accuracy of the probability map and subsequent segmentation have been improved We collected 1746 IVUS images from 18 patients in this study. The whole dataset was split into a training dataset (1572 images) for the 10-fold cross-validation and a test dataset (174 images) for evaluating the performance of models. Our IVUS-U-Net++ segmentation model achieved a Jaccard measure (JM) of 0.9412, a Hausdorff distance (HD) of 0.0639 mm for the lumen border, and a JM of 0.9509, an HD of 0.0867 mm for the MA border, respectively. Moreover, the Pearson correlation and Bland-Altman analyses were performed to evaluate the correlations of 12 clinical parameters measured from our segmentation results and the ground truth, and automatic measurements agreed well with those from the ground truth (all Ps<0.01). In conclusion, our preliminary results demonstrate that the proposed IVUS-U-Net++ model has great promise for clinical use.

preprint2021arXiv

A new approach to extracting coronary arteries and detecting stenosis in invasive coronary angiograms

In stable coronary artery disease (CAD), reduction in mortality and/or myocardial infarction with revascularization over medical therapy has not been reliably achieved. Coronary arteries are usually extracted to perform stenosis detection. We aim to develop an automatic algorithm by deep learning to extract coronary arteries from ICAs.In this study, a multi-input and multi-scale (MIMS) U-Net with a two-stage recurrent training strategy was proposed for the automatic vessel segmentation. Incorporating features such as the Inception residual module with depth-wise separable convolutional layers, the proposed model generated a refined prediction map with the following two training stages: (i) Stage I coarsely segmented the major coronary arteries from pre-processed single-channel ICAs and generated the probability map of vessels; (ii) during the Stage II, a three-channel image consisting of the original preprocessed image, a generated probability map, and an edge-enhanced image generated from the preprocessed image was fed to the proposed MIMS U-Net to produce the final segmentation probability map. During the training stage, the probability maps were iteratively and recurrently updated by feeding into the neural network. After segmentation, an arterial stenosis detection algorithm was developed to extract vascular centerlines and calculate arterial diameters to evaluate stenotic level. Experimental results demonstrated that the proposed method achieved an average Dice score of 0.8329, an average sensitivity of 0.8281, and an average specificity of 0.9979 in our dataset with 294 ICAs obtained from 73 patient. Moreover, our stenosis detection algorithm achieved a true positive rate of 0.6668 and a positive predictive value of 0.7043.

preprint2020arXiv

3D Fusion between Fluoroscopy Angiograms and SPECT Myocardial Perfusion Images to Guide Percutaneous Coronary Intervention

Background. Percutaneous coronary intervention(PCI) in stable coronary artery disease(CAD) is commonly triggered by abnormal myocardial perfusion imaging(MPI). However, due to the possibilities of multivessel disease and variability of coronary artery perfusion distribution, opportunity exists to better align anatomic stenosis with perfusion abnormalities to improve revascularization decisions. This study aims to develop a 3D multi-modality fusion approach to assist decision-making for PCI. Methods. Coronary arteries from fluoroscopic angiography(FA) were reconstructed into 3D artery anatomy. Left ventricular(LV) epicardial surface was extracted from SPECT. The 3D artery anatomy was non-rigidly fused with the LV epicardial surface. The accuracy of the 3D fusion was evaluated via both computer simulation and real patient data. For technical validation, simulated FA and MPI were integrated and then compared with the ground truth from a digital phantom. For clinical validation, FA and SPECT images were integrated and then compared with the ground truth from CT angiograms. Results. In the technical evaluation, the distance-based mismatch error between simulated fluoroscopy and phantom arteries is 1.86(SD:1.43)mm for left coronary arteries(LCA) and 2.21(SD:2.50)mm for right coronary arteries(RCA). In the clinical validation, the distance-based mismatch errors between the fluoroscopy and CT arteries were 3.84(SD:3.15)mm for LCA and 5.55(SD:3.64)mm for RCA. The presence of the corresponding fluoroscopy and CT arteries in the AHA 17-segment model agreed well with a Kappa value of 0.91(95% CI: 0.89-0.93) for LCA and 0.80(CI: 0.67-0.92) for RCA. Conclusions. Our fusion approach is technically accurate to assist PCI decision-making and is clinically feasible to be used in the catheterization laboratory. There is an opportunity to improve the decision-making and outcomes of PCI in stable CAD.

preprint2020arXiv

A Deep Learning-Based Method for Automatic Segmentation of Proximal Femur from Quantitative Computed Tomography Images

Purpose: Proximal femur image analyses based on quantitative computed tomography (QCT) provide a method to quantify the bone density and evaluate osteoporosis and risk of fracture. We aim to develop a deep-learning-based method for automatic proximal femur segmentation. Methods and Materials: We developed a 3D image segmentation method based on V-Net, an end-to-end fully convolutional neural network (CNN), to extract the proximal femur QCT images automatically. The proposed V-net methodology adopts a compound loss function, which includes a Dice loss and a L2 regularizer. We performed experiments to evaluate the effectiveness of the proposed segmentation method. In the experiments, a QCT dataset which included 397 QCT subjects was used. For the QCT image of each subject, the ground truth for the proximal femur was delineated by a well-trained scientist. During the experiments for the entire cohort then for male and female subjects separately, 90% of the subjects were used in 10-fold cross-validation for training and internal validation, and to select the optimal parameters of the proposed models; the rest of the subjects were used to evaluate the performance of models. Results: Visual comparison demonstrated high agreement between the model prediction and ground truth contours of the proximal femur portion of the QCT images. In the entire cohort, the proposed model achieved a Dice score of 0.9815, a sensitivity of 0.9852 and a specificity of 0.9992. In addition, an R2 score of 0.9956 (p<0.001) was obtained when comparing the volumes measured by our model prediction with the ground truth. Conclusion: This method shows a great promise for clinical application to QCT and QCT-based finite element analysis of the proximal femur for evaluating osteoporosis and hip fracture risk.

preprint2020arXiv

A Novel Method for ECG Signal Classification via One-Dimensional Convolutional Neural Network

This paper presents an end-to-end ECG signal classification method based on a novel segmentation strategy via 1D Convolutional Neural Networks (CNN) to aid the classification of ECG signals. The ECG segmentation strategy named R-R-R strategy (i.e., retaining ECG data between the R peaks just before and after the current R peak) for segmenting the original ECG data into segments in order to train and test the 1D CNN models. The novel strategy mimics physicians in scanning ECG to a greater extent, and maximizes the inherent information of ECG segments. The performance of the classification models for 5-class and 6-class are verified with ECG signals from 48 records of the MIT-BIH arrhythmia database. As the heartbeat types are divided into 5 classes (i.e., normal beat, left bundle branch block beat, right bundle branch block beat, ventricular ectopic beat, and paced beat) in the MIT-BIH, the best classification accuracy, the area under the curve (AUC), the sensitivity and the F1-score reach 99.24%, 0.9994, 0.99 and 0.99, respectively. As the heartbeat types are divided into 6 classes (i.e., normal beat, left bundle branch block beat, right bundle branch block beat, ventricular ectopic beat, paced beat and other beats) in the MIT-BIH, the beat classification accuracy, the AUC, the sensitivity, and the F1-score reach 97.02%, 0.9966, 0.97, and 0.97, respectively. Meanwhile, according to the recommended practice from the Association for Advancement of Medical Instrumentation (AAMI), the heartbeat types are divided into 5 classes (i.e., normal beat, supraventricular ectopic beats, ventricular ectopic beats, fusion beats, and unclassifiable beats), the beat classification accuracy, the sensitivity, and the F1-score reach 97.45%, 0.97, and 0.97, respectively. The experimental results show that the proposed method achieves better performance than the state-of-the-art methods.