Source author record

Vladislav Balagura

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
3topics
4close collaborators

Published work

3 publications

preprint2020arXiv

Van der Meer Scan Luminosity Measurement and Beam-Beam Correction

The main method for calibrating the luminosity at Large Hadron Collider (LHC) is van der Meer scan where the beams are swept transversely across each other. This beautiful method was invented in 1968. Despite the honourable age, it remains the preferable tool at hadron colliders. It delivers the lowest calibration systematics, which still often dominates the overall luminosity uncertainty at LHC experiments. Various details of the method are discussed in the paper. One of the main factors limiting proton-proton van der Meer scan accuracy is the beam-beam electromagnetic interaction. It modifies the shapes of the colliding bunches and biases the measured luminosity. In the first years of operation, four main LHC experiments did not attempt to correct the bias because of its complexity. In 2012 a correction method was proposed and then subsequently used by all experiments. It was based, however, on a simplified linear approximation of the beam-beam force and, therefore, had limited accuracy. In this paper, a new simulation is presented, which takes into account the exact non-linear force. Depending on the beam parameters, the results of the new and old methods differ by ∼1%\sim1\%. This needs to be propagated to all LHC cross-section measurements after 2012. The new simulation is going to be used at LHC in future luminosity calibrations.

preprint2016arXiv

Reconstruction and classification of tau lepton decays with ILD

Tau-lepton decays with up to two π0π^0's in the final state, τ+→π+νˉττ^+ \to π^+ \barν_τ, ρ+(π+π0)νˉτρ^+ (π^+π^0) \barν_τ, a1+(π+π0π0)νˉτa^+_1 (π^+π^0π^0) \barν_τ, are used to study the performance of the barrel part of the silicon-tungsten electromagnetic calorimeter (Si-W ECAL) of the International Large Detector (ILD) at the future e+−e−e^+-e^- International Linear Collider. A correct reconstruction of the tau decay mode is crucial for constraining the tau spin state and measuring the Higgs boson CP state in H→τ+τ−H\to τ^+τ^- decays. About 95% of π+νˉτπ^+ \barν_τ and 90% of ρ+νˉτρ^+\barν_τ and a1+νˉτa^+_1\barν_τ decays from e+e−→Z0→τ+τ−e^+e^-\to Z^0\to τ^+τ^- reaction at e±e^\pm-beam energy of 125 GeV are correctly reconstructed. In a smaller ILD detector, with Si-W ECAL radius reduced by about 20% these numbers degrade by at most 2%. The π0π^0 mass resolution stays below 10%. Since the failures in the tau-lepton reconstruction are mainly due to photons, the increase of the ILD magnetic field from 3.5 T to 4 T does not bring any significant improvement.

preprint2011arXiv

Notes on van der Meer Scan for Absolute Luminosity Measurement

An absolute luminosity can be measured in an accelerator by sweeping beams transversely across each other in the so called van der Meer scan. We prove that the method can be applied in the general case of arbitrary beam directions and a separation scan plane. A simple method to develop an image of the beam in its transverse plane from spatial distributions of interaction vertexes is also proposed. From the beam images one can determine their overlap and the absolute luminosity. This provides an alternative way of the luminosity measurement during van der Meer scan.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.