Source author record

Trong Hieu Tran

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
2topics
4close collaborators

Published work

2 publications

preprint2016arXiv

Reconstruction and classification of tau lepton decays with ILD

Tau-lepton decays with up to two π0π^0's in the final state, τ+→π+νˉττ^+ \to π^+ \barν_τ, ρ+(π+π0)νˉτρ^+ (π^+π^0) \barν_τ, a1+(π+π0π0)νˉτa^+_1 (π^+π^0π^0) \barν_τ, are used to study the performance of the barrel part of the silicon-tungsten electromagnetic calorimeter (Si-W ECAL) of the International Large Detector (ILD) at the future e+−e−e^+-e^- International Linear Collider. A correct reconstruction of the tau decay mode is crucial for constraining the tau spin state and measuring the Higgs boson CP state in H→τ+τ−H\to τ^+τ^- decays. About 95% of π+νˉτπ^+ \barν_τ and 90% of ρ+νˉτρ^+\barν_τ and a1+νˉτa^+_1\barν_τ decays from e+e−→Z0→τ+τ−e^+e^-\to Z^0\to τ^+τ^- reaction at e±e^\pm-beam energy of 125 GeV are correctly reconstructed. In a smaller ILD detector, with Si-W ECAL radius reduced by about 20% these numbers degrade by at most 2%. The π0π^0 mass resolution stays below 10%. Since the failures in the tau-lepton reconstruction are mainly due to photons, the increase of the ILD magnetic field from 3.5 T to 4 T does not bring any significant improvement.

preprint2014arXiv

ILD SiW ECAL and sDHCAL dimension-performance optimisation

The ILD, International Large Detector, is one of the detector concepts for a future linear collider. Its performance is investigated using Monte-Carlo full simulation and PandoraPFA. Among several options, a combination of the silicon-tungsten electromagnetic calorimeter (SiW ECAL) and the semi-digital hadronic calorimeter (sDHCAL) presenting the highest granularity calorimeters, is here investigated. It is shown that by reducing the radius and length of the entire detector by a factor of ∼1.3\sim1.3 with respect to the baseline dimensions, the jet energy resolution is degraded by 8 to 19% in the range of 45 and 250 GeV. The price of ILD which scales roughly quadratically with the ILD dimensions may be reduced by a factor of nearly two. A similar study made with the SiW ECAL and the analog hadronic calorimeter (AHCAL) shows that for an inner radius of ECAL of about~1.4 m, the performance is comparable between sDHCAL and AHCAL.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.