Researcher profile

Vincent Maurice

Vincent Maurice contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Laser-actuated hermetic seals for integrated atomic devices

Atomic devices such as atomic clocks and optically-pumped magnetometers rely on the interrogation of atoms contained in a cell whose inner content has to meet high standards of purity and accuracy. Glass-blowing techniques and craftsmanship have evolved over many decades to achieve such standards in macroscopic vapor cells. With the emergence of chip-scale atomic devices, the need for miniaturization and mass fabrication has led to the adoption of microfabrication techniques to make millimeter-scale vapor cells. However, many shortcomings remain and no process has been able to match the quality and versatility of glass-blown cells. Here, we introduce a novel approach to structure, fill and seal microfabricated vapor cells inspired from the century-old approach of glass-blowing. In particular we demonstrate opening and closing single-use zero-leak microfabricated valves, actuated exclusively by laser, and operating in the same way as the "make-seals" and "break-seals" found in the filling apparatus of traditional cells. Such structures are employed to fill cesium vapor cells at the wafer-level. The make-seal structure consists of a glass membrane that can be locally heated and deflected to seal a microchannel. The break-seal is obtained by breaching a silicon wall between cavities. This new approach allows adapting processes previously restricted to glass-blown cells. It can also be extended to vacuum microelectronics and vacuum-packaging of micro-electro-mechanical systems (MEMS) devices.

preprint2020arXiv

Advanced protection against environmental degradation of silver mirror stacks for space application

Protection of silver mirror stacks from environmental degradation before launching is crucial for space applications. Hereby, we report a comparative study of the advanced protection of silver mirror stacks for space telescopes provided by SiO2 and Al2O3 coatings in conditions of accelerated aging by sulfidation. The model silver stack samples were deposited by cathodic magnetron sputtering on a reference silica substrate for optical applications and a surface-pretreated SiC substrate. Accelerated aging was performed in dry and more severe wet conditions. Optical micrographic observations, surface and interface analysis by Time-of Flight Secondary Ion Mass Spectrometry (ToF-SIMS) and reflectivity measurements were combined to comparatively study the effects of degradation. The results show a lower kinetics of degradation by accelerated aging of the stacks protected by the alumina coating in comparable test conditions.

preprint2020arXiv

Enhanced observation time of magneto-optical traps using micro-machined non-evaporable getter pumps

We show that micro-machined non-evaporable getter pumps (NEGs) can extend the time over which laser cooled atoms canbe produced in a magneto-optical trap (MOT), in the absence of other vacuum pumping mechanisms. In a first study, weincorporate a silicon-glass microfabricated ultra-high vacuum (UHV) cell with silicon etched NEG cavities and alumino-silicateglass (ASG) windows and demonstrate the observation of a repeatedly-loading MOT over a 10 minute period with a single laser-activated NEG. In a second study, the capacity of passive pumping with laser activated NEG materials is further investigated ina borosilicate glass-blown cuvette cell containing five NEG tablets. In this cell, the MOT remained visible for over 4 days withoutany external active pumping system. This MOT observation time exceeds the one obtained in the no-NEG scenario by almostfive orders of magnitude. The cell scalability and potential vacuum longevity made possible with NEG materials may enable inthe future the development of miniaturized cold-atom instruments.

preprint2020arXiv

Miniaturized optical frequency standard for next-generation portable optical clocks

Optical frequency standards, lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency standard based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. The optical standard achieves a fractional frequency stability of 2.9x10$^{-12}$/$\sqrtτ$ for averaging times $τ$ less than 10$^{3}$ s, has a volume of $\approx$35 cm$^3$ and operates on $\approx$450 mW of electrical power. These results demonstrate a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.

preprint2020arXiv

Passivation mechanisms and pre-oxidation effects on model surfaces of FeCrNi austenitic stainless steel

Passivation mechanisms were investigated on (100)-oriented Fe-18Cr-13Ni surfaces with direct transfer between surface preparation and analysis by X-ray photoelectron spectroscopy and scanning tunneling microscopy and electrochemical characterization. Starting from oxide-free surfaces, pre-oxidation at saturation under ultra-low pressure (ULP) oxygen markedly promotes the oxide film Cr(III) enrichment and hinders/delays subsequent iron oxidation in water-containing environment. Exposure to sulfuric acid at open circuit potential causes preferential dissolution of oxidized iron species. Anodic passivation forces oxide film re-growth, Cr(III) dehydroxylation and further enrichment. ULP pre-oxidation promotes Cr(III) hydroxide formation at open circuit potential, compactness of the nanogranular oxide film and corrosion protection.

preprint2015arXiv

Characterization of Cs vapor cell coated with octadecyltrichlorosilane using coherent population trapping spectroscopy

We report the realization and characterization using coherent population trapping (CPT) spectroscopy of an octadecyltrichlorosilane (OTS)-coated centimeter-scale Cs vapor cell. The dual-structure of the resonance lineshape, with presence of a narrow structure line at the top of a Doppler-broadened structure, is clearly observed. The linewidth of the narrow resonance is compared to the linewidth of an evacuated Cs cell and of a buffer gas Cs cell of similar size. The Cs-OTS adsorption energy is measured to be (0.42 $\pm$ 0.03) eV, leading to a clock frequency shift rate of $2.7\times10^{-9}/$K in fractional unit. A hyperfine population lifetime, $T_1$, and a microwave coherence lifetime, $T_2$, of 1.6 and 0.5 ms are reported, corresponding to about 37 and 12 useful bounces, respectively. Atomic-motion induced Ramsey narrowing of dark resonances is observed in Cs-OTS cells by reducing the optical beam diameter. Ramsey CPT fringes are detected using a pulsed CPT interrogation scheme. Potential applications of the Cs-OTS cell to the development of a vapor cell atomic clock are discussed.