Source author record

Travis Sawyer

Travis Sawyer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm/s, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser frequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on radial velocity precision due to pixel-position non-uniformities (PPNU) and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter-McLaughlin effect.

preprint2018arXiv

Quantitative phase and polarisation endoscopy applied to detection of early oesophageal tumourigenesis

Phase and polarisation of coherent light are highly perturbed by interaction with microstructural changes in pre-malignant tissue, holding promise for label-free early cancer detection in endoscopically accessible tissues such as the gastrointestinal tract. Flexible optical fibres used in conventional diagnostic endoscopy scramble phase and polarisation, restricting clinicians instead to low-contrast amplitude-only imaging. Here, we unscramble phase and polarisation images by exploiting the near-diagonal multi-core fibre (MCF) transmission matrix to create a novel parallelised fibre characterisation architecture, scalable to arbitrary MCFs without additional experimental overhead. Our flexible MCF holographic endoscope produces full-field en-face images of amplitude, quantitative phase and resolved polarimetric properties using a low-cost laser diode and camera. We demonstrate that recovered phase enables computational re-focusing at working distances up to 1mm over a field-of-view up to 750$\times$750 $μm^2$. Furthermore, we demonstrate that the spatial distribution of phase and polarisation information enables label-free visualisation of early tumours in oesophageal mouse issue that are not identifiable using conventional amplitude-only information, a milestone towards future application for early cancer detection in endoscopy.