Source author record

Bijan Nemati

Bijan Nemati appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

Flatfield Calibrations with Astrophysical Sources for the Nancy Grace Roman Space Telescope's Coronagraph Instrument

The Nancy Grace Roman Space Telescope Coronagraph Instrument is a high-contrast imager, polarimeter, and spectrometer that will enable the study of exoplanets and circumstellar disks at visible wavelengths ($\sim$550--850~nm) at contrasts 2--3 orders of magnitude better than can currently be achieved by ground or space-based direct imaging facilities. To capitalize on this sensitivity, precise flux calibration will be required. The Roman Coronagraph, like other space-based missions, will use on-orbit flatfields to measure and correct for phenomena that impact the measured total effective throughput. However, the Coronagraph does not have internal lamp sources, therefore we have developed a method to perform flatfield calibrations using observations of extended sources, such as Uranus and Neptune, using a combination of rastering the Coronagraph's Fast Steering Mirror, tiling the planet across the field of view, and matched-filter image processing. Here we outline the process and present the results of simulations using images of Uranus and Neptune from the Hubble Space Telescopes Wide Field Camera 3, in filters approximate to the Coronagraph's Band 1 and Band 4. The simulations are performed over the Coronagraph's direct imaging and polarimetric modes. We model throughput effects in 3 different spatial frequency regimes including 1) high spatial frequency detector pixel-to-pixel quantum efficiency variations, 2) medium spatial frequency "measles" caused by particle deposition on the detector or other focal-plane optics post-launch, and 3) low spatial frequency detector fringing caused by self-interference due to internal reflections in the detector substrate as well as low spatial frequency vignetting at the edges of the Coronagraph's field of view. We show that Uranus and Neptune can be used as astrophysical flat sources with high precision ($\sim$0.5% relative error)

preprint2022arXiv

Nancy Grace Roman Space Telescope Coronagraph Instrument Observation Calibration Plan

NASA's next flagship mission, the Nancy Grace Roman Space Telescope, is a 2.4-meter observatory set to launch no later than May 2027. Roman features two instruments: the Wide Field Imager and the Coronagraph Instrument. Roman's Coronagraph is a Technology Demonstration that will push the current capabilities of direct imaging to smaller contrast ratios ($\sim$10$^{-9}$) and inner-working angles (3~$λ$/D). In order to achieve this high precision, Roman Coronagraph data must be calibrated to remove as many potential sources of error as possible. Here we present a detailed overview of the Nancy Grace Roman Space Telescope Coronagraph Instrument Observation Calibration Plan including identifying potential sources of error and how they will be mitigated via on-sky calibrations.

preprint2021arXiv

Sensitivity of the Roman Coronagraph Instrument to Exozodiacal Dust

Exozodiacal dust, warm debris from comets and asteroids in and near the habitable zone of stellar systems, reveals the physical processes that shape planetary systems. Scattered light from this dust is also a source of background flux which must be overcome by future missions to image Earthlike planets. This study quantifies the sensitivity of the Nancy Grace Roman Space Telescope Coronagraph to light scattered by exozodi, the zodiacal dust around other stars. Using a sample of 149 nearby stars, previously selected for optimum detection of habitable exoplanets by space observatories, we find the maximum number of exozodiacal disks with observable \textit{inner} habitable zone boundaries is six and the number of observable outer habitable boundaries is 74. One zodi was defined as the visible-light surface brightness of 22 $m_{\rm V}\ $arcsec$^{-2}$ around a solar-mass star, approximating the scattered light brightness in visible light at the Earth-equivalent insolation. In the speckle limited case, where the signal-to-noise ratio is limited by speckle temporal stability rather than shot noise, the median $5σ$ sensitivity to habitable zone exozodi is 12 zodi per resolution element. This estimate is calculated at the inner-working angle of the coronagraph, for the current best estimate performance, neglecting margins on the uncertainty in instrument performance and including a post-processing speckle suppression factor. For an log-norm distribution of exozodi levels with a median exozodi of 3$\times$ the solar zodi, we find that the Roman Coronagraph would be able to make 5$σ$ detections of exozodiacal disks in scattered light from 13 systems with a 95\% confidence interval spanning 7-20 systems. This sensitivity allows Roman Coronagraph to complement ground-based measurements of exozodiacal thermal emission and constrain dust albedos.

preprint2021arXiv

The Nancy Grace Roman Space Telescope Coronagraph Instrument (CGI) Technology Demonstration

The Coronagraph Instrument (CGI) on the Nancy Grace Roman Space Telescope will demonstrate the high-contrast technology necessary for visible-light exoplanet imaging and spectroscopy from space via direct imaging of Jupiter-size planets and debris disks. This in-space experience is a critical step toward future, larger missions targeted at direct imaging of Earth-like planets in the habitable zones of nearby stars. This paper presents an overview of the current instrument design and requirements, highlighting the critical hardware, algorithms, and operations being demonstrated. We also describe several exoplanet and circumstellar disk science cases enabled by these capabilities. A competitively selected Community Participation Program team will be an integral part of the technology demonstration and could perform additional CGI observations beyond the initial tech demo if the instrument performance warrants it.

preprint2020arXiv

Laboratory Demonstration of Spatial Linear Dark Field Control For Imaging Extrasolar Planets in Reflected Light

Imaging planets in reflected light, a key focus of future NASA missions and ELTs, requires advanced wavefront control to maintain a deep, temporally correlated null of stellar halo -- i.e. a dark hole -- at just several diffraction beam widths. Using the Ames Coronagraph Experiment testbed, we present the first laboratory tests of Spatial Linear Dark Field Control (LDFC) approaching raw contrasts ($\sim$ 5$\times$10$^{-7}$) and separations (1.5--5.2 $λ$/D) needed to image jovian planets around Sun-like stars with space-borne coronagraphs like WFIRST-CGI and image exo-Earths around low-mass stars with future ground-based 30m class telescopes. In four separate experiments and for a range of different perturbations, LDFC largely restores (to within a factor of 1.2--1.7) and maintains a dark hole whose contrast is degraded by phase errors by an order of magnitude. Our implementation of classical speckle nulling requires a factor of 2--5 more iterations and 20--50 DM commands to reach contrasts obtained by spatial LDFC. Our results provide a promising path forward to maintaining dark holes without relying on DM probing and in the low-flux regime, which may improve the duty cycle of high-contrast imaging instruments, increase the temporal correlation of speckles, and thus enhance our ability to image true solar system analogues in the next two decades.

preprint2020arXiv

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm/s, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser frequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on radial velocity precision due to pixel-position non-uniformities (PPNU) and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter-McLaughlin effect.

preprint2020arXiv

The Habitable Exoplanet Observatory (HabEx) Mission Concept Study Final Report

The Habitable Exoplanet Observatory, or HabEx, has been designed to be the Great Observatory of the 2030s. For the first time in human history, technologies have matured sufficiently to enable an affordable space-based telescope mission capable of discovering and characterizing Earthlike planets orbiting nearby bright sunlike stars in order to search for signs of habitability and biosignatures. Such a mission can also be equipped with instrumentation that will enable broad and exciting general astrophysics and planetary science not possible from current or planned facilities. HabEx is a space telescope with unique imaging and multi-object spectroscopic capabilities at wavelengths ranging from ultraviolet (UV) to near-IR. These capabilities allow for a broad suite of compelling science that cuts across the entire NASA astrophysics portfolio. HabEx has three primary science goals: (1) Seek out nearby worlds and explore their habitability; (2) Map out nearby planetary systems and understand the diversity of the worlds they contain; (3) Enable new explorations of astrophysical systems from our own solar system to external galaxies by extending our reach in the UV through near-IR. This Great Observatory science will be selected through a competed GO program, and will account for about 50% of the HabEx primary mission. The preferred HabEx architecture is a 4m, monolithic, off-axis telescope that is diffraction-limited at 0.4 microns and is in an L2 orbit. HabEx employs two starlight suppression systems: a coronagraph and a starshade, each with their own dedicated instrument.

preprint2016arXiv

Technology advancement of the CCD201-20 EMCCD for the WFIRST coronagraph instrument: sensor characterization and radiation damage

The Wide Field InfraRed Survey Telescope-Astrophysics Focused Telescope Asset (WFIRST-AFTA) mission is a 2.4-m class space telescope that will be used across a swath of astrophysical research domains. JPL will provide a high-contrast imaging coronagraph instrument - one of two major astronomical instruments. In order to achieve the low noise performance required to detect planets under extremely low flux conditions, the electron multiplying charge-coupled device (EMCCD) has been baselined for both of the coronagraph's sensors - the imaging camera and integral field spectrograph. JPL has established an EMCCD test laboratory in order to advance EMCCD maturity to technology readiness level-6. This plan incorporates full sensor characterization, including read noise, dark current, and clock-induced charge. In addition, by considering the unique challenges of the WFIRST space environment, degradation to the sensor's charge transfer efficiency will be assessed, as a result of damage from high-energy particles such as protons, electrons, and cosmic rays. Science-grade CCD201-20 EMCCDs have been irradiated to a proton fluence that reflects the projected WFIRST orbit. Performance degradation due to radiation displacement damage is reported, which is the first such study for a CCD201-20 that replicates the WFIRST conditions. In addition, techniques intended to identify and mitigate radiation-induced electron trapping, such as trap pumping, custom clocking, and thermal cycling, are discussed.

preprint2015arXiv

Demonstration of high contrast with an obscured aperture with the WFIRST-AFTA shaped pupil coronagraph

The coronagraph instrument on the WFIRST-AFTA mission study has two coronagraphic architectures, shaped pupil and hybrid Lyot, which may be interchanged for use in different observing scenarios. Each architecture relies on newly-developed mask components to function in the presence of the AFTA aperture, and so both must be matured to a high technology readiness level (TRL) in advance of the mission. A series of milestones were set to track the development of the technologies required for the instrument; in this paper, we report on completion of WFIRST-AFTA Coronagraph Milestone 2---a narrowband $10^{-8}$ contrast test with static aberrations for the shaped pupil---and the plans for the upcoming broadband Coronagraph Milestone 5.

preprint2015arXiv

Numerical modelling of the proposed WFIRST-AFTA coronagraphs and their predicted optical performances

The WFIRST-AFTA 2.4 m telescope will provide in the next decade the opportunity to host a coronagraph for the imaging and spectroscopy of planets and disks. The telescope, however, is not ideal, given its obscured aperture. Only recently have coronagraph designs been thoroughly investigated that can efficiently work with this configuration. Three coronagraph designs, the hybrid Lyot, the shaped pupil, and the phase-induced amplitude-apodization complex mask coronagraph (PIAA-CMC) have been selected for further development by the AFTA project. Real-world testbed demonstrations of these have just begun, so for now the most reliable means of evaluating their potential performance comes from numerical modeling incorporating diffraction propagation, realistic system models, and simulated wavefront sensing and control. Here we present the methods of performance evaluation and results for the current coronagraph designs.

preprint2014arXiv

Detection of a faint fast-moving near-Earth asteroid using synthetic tracking technique

We report a detection of a faint near-Earth asteroid (NEA), which was done using our synthetic tracking technique and the CHIMERA instrument on the Palomar 200-inch telescope. This asteroid, with apparent magnitude of 23, was moving at 5.97 degrees per day and was detected at a signal-to-noise ratio (SNR) of 15 using 30 sec of data taken at a 16.7 Hz frame rate. The detection was confirmed by a second observation one hour later at the same SNR. The asteroid moved 7 arcseconds in sky over the 30 sec of integration time because of its high proper motion. The synthetic tracking using 16.7 Hz frames avoided the trailing loss suffered by conventional techniques relying on 30-sec exposure, which would degrade the surface brightness of image on CCD to an approximate magnitude of 25. This detection was a result of our 12-hour blind search conducted on the Palomar 200-inch telescope over two nights on September 11 and 12, 2013 scanning twice over six 5.0 deg x 0.043 deg fields. The fact that we detected only one NEA, is consistent with Harris's estimation of the asteroid population distribution, which was used to predict the detection of 1--2 asteroids of absolute magnitude H=28--31 per night. The design of experiment, data analysis method, and algorithms for estimating astrometry are presented. We also demonstrate a milli-arcsecond astrometry using observations of two bright asteroids with the same system on Apr 3, 2013. Strategies of scheduling observations to detect small and fast-moving NEAs with the synthetic tracking technique are discussed.

preprint2013arXiv

Finding Very Small Near-Earth Asteroids using Synthetic Tracking

We present an approach that significantly increases the sensitivity for finding and tracking small and fast near Earth asteroids (NEA's). This approach relies on a combined use of a new generation of high-speed cameras which allow short, high frame-rate exposures of moving objects, effectively "freezing" their motion, and a computationally enhanced implementation of the "shift-and-add" data processing technique that helps to improve the signal to noise ratio (SNR) for detection of NEA's. The SNR of a single short exposure of a dim NEA is insufficient to detect it in one frame, but by computationally searching for an appropriate velocity vector, shifting successive frames relative to each other and then co-adding the shifted frames in post-processing, we synthetically create a long-exposure image as if the telescope were tracking the object. This approach, which we call "synthetic tracking," enhances the familiar shift-and-add technique with the ability to do a wide blind search, detect, and track dim and fast-moving NEA's in near real time. We discuss also how synthetic tracking improves the astrometry of fast moving NEA's. We apply this technique to observations of two known asteroids conducted on the Palomar 200-inch telescope and demonstrate improved SNR and 10-fold improvement of astrometric precision over the traditional long exposure approach. In the past 5 years, about 150 NEA's with absolute magnitudes H=28 (~10 m in size) or fainter have been discovered. With an upgraded version of our camera and a field of view of (28 arcmin)^2 on the Palomar 200-inch telescope, synthetic tracking could allow detecting up to 180 such objects per night, including very small NEAs with sizes down to 7 m.

preprint2011arXiv

Micro-pixel accuracy centroid displacement estimation and detector calibration

Precise centroid estimation plays a critical role in accurate astrometry using telescope images. Conventional centroid estimation fits a template point spread function (PSF) to the image data. Because the PSF is typically not known to high accuracy due to wavefront aberrations and uncertainties in optical system, a simple Gaussian function is commonly used. PSF knowledge error leads to systematic errors in the conventional centroid estimation. In this paper, we present an accurate centroid estimation algorithm by reconstructing the PSF from well sampled (above Nyquist frequency) pixelated images. In the limit of an ideal focal plane array whose pixels have identical response function (no inter-pixel variation), this method can estimate centroid displacement between two 32$\times$32 images to sub-micropixel accuracy. Inter-pixel response variations exist in real detectors, {\it e.g.}~CCDs, which we can calibrate by measuring the pixel response of each pixel in Fourier space. The Fourier transforms of the inter-pixel variations of pixel response functions can be conveniently expressed in terms of powers of spatial wave numbers using their Taylor series expansions. Calibrating up to the third order terms in this expansion, we show that our centroid displacement estimation is accurate to a few micro-pixels using simulated data. This algorithm is applicable to the new proposed mission concept Nearest Earth Astrometry Telescope (NEAT) to achieve mirco-arcsecond accuracy in relative astrometry for detecting terrestrial exoplanets. This technology is also applicable to high precision photometry missions.