Source author record

Thomas Vogt

Thomas Vogt appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

Assessment of the regionalised demand response potential in Germany using an open source tool and dataset

With the expansion of renewable energies in Germany, imminent grid congestion events occur more often. One approach for avoiding curtailment of renewable energies is to cover excess feed-in by demand response. As curtailment is often a local phenomenon, in this work we determine the regional demand response potential for the 401 German administrative districts. The load regionalisation is based on weighting factors derived from population and employment statistics, locations of industrial facilities, etc. Using periodic and temperature-dependent load profiles and technology specific parameters, load shifting potentials were determined with a temporal resolution of 15 minutes. Our analysis yields that power-to-heat technologies provide the highest potentials, followed by residential appliances, commercial and industrial loads. For the considered 2030 scenario, power-to-gas and e-mobility also contribute a significant potential. The cumulated load increase potential of all technologies ranges from $5 - 470~MW$ per administrative district. The median value is $25~MW$, which would suffice to avoid the curtailment of 8 classical wind turbines. Further, we calculated load shifting cost-potential curves for each district. Industrial processes and power-to-heat in district heating have the lowest load shifting investment cost, due to the largest installed capacities per facility. We distinguished between different size classes of the installed capacity of heat pumps, yielding $23\%$ lower average investment cost for heat pump flexibilisation in the city of Berlin compared to a rural district. The variable costs of most considered load shifting technologies remain under the average compensation costs for curtailment of renewable energies of $110~\text{\euro{}}/MWh$. As all results and the developed code are published under open source licenses, they can be integrated into energy system models.

preprint2020arXiv

On the Connection between Dynamical Optimal Transport and Functional Lifting

Functional lifting methods provide a tool for approximating solutions of difficult non-convex problems by embedding them into a larger space. In this work, we investigate a mathematically rigorous formulation based on embedding into the space of pointwise probability measures over a fixed range $Γ$. Interestingly, this approach can be derived as a generalization of the theory of dynamical optimal transport. Imposing the established continuity equation as a constraint corresponds to variational models with first-order regularization. By modifying the continuity equation, the approach can also be extended to models with higher-order regularization.

preprint2014arXiv

Integration of Renewable Energy Sources in Future Power Systems: The Role of Storage

Integrating a high share of electricity from non-dispatchable Renewable Energy Sources in a power supply system is a challenging task. One option considered in many studies dealing with prospective power systems is the installation of storage devices to balance the fluctuations in power production. However, it is not yet clear how soon storage devices will be needed and how the integration process depends on different storage parameters. Using long-term solar and wind energy power production data series, we present a modelling approach to investigate the influence of storage size and efficiency on the pathway towards a 100% RES scenario. Applying our approach to data for Germany, we found that up to 50% of the overall electricity demand can be met by an optimum combination of wind and solar resources without both curtailment and storage devices if the remaining energy is provided by sufficiently flexible power plants. Our findings show further that the installation of small, but highly efficient storage devices is already highly beneficial for the RES integration, while seasonal storage devices are only needed when more than 80% of the electricity demand can be met by wind and solar energy. Our results imply that a compromise between the installation of additional generation capacities and storage capacities is required.

preprint2014arXiv

Optimized imaging using non-rigid registration

The extraordinary improvements of modern imaging devices offer access to data with unprecedented information content. However, widely used image processing methodologies fall far short of exploiting the full breadth of information offered by numerous types of scanning probe, optical, and electron microscopies. In many applications, it is necessary to keep measurement intensities below a desired threshold. We propose a methodology for extracting an increased level of information by processing a series of data sets suffering, in particular, from high degree of spatial uncertainty caused by complex multiscale motion during the acquisition process. An important role is played by a nonrigid pixel-wise registration method that can cope with low signal-to-noise ratios. This is accompanied by formulating objective quality measures which replace human intervention and visual inspection in the processing chain. Scanning transmission electron microscopy of siliceous zeolite material exhibits the above-mentioned obstructions and therefore serves as orientation and a test of our procedures.

preprint2004arXiv

Structural Distortion and Disappearance of Layer Ordering in LixCoO2x2H2O

The structure of a new member of the AxCoO2 x nH2O family (A=Li,Na,K) was determined by high-resolution synchrotron X-ray powder diffraction. Layered lithium cobalt oxide hydrate LixCoO2 x 2H2O crystallizes in a disordered monoclinic structure (space group C2/m) with lattice parameters a = 4.8915(2) A, b = 2.8239(1) A, c = 10.7033(9) A, beta = 112.386(4)deg. Unlike the superconducting sodium cobalt oxide hydrate, this material possesses a structure with lithium-water layers intercalated between disordered octahedral sheets of cobalt oxide. The interlayer spacing is slightly larger (~0.9%) due to the higher water content, and one of the two lithium sites extends into the water layer. This material shows no superconducting transition above 2K.