Researcher profile

Theodor Steffen

Theodor Steffen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2026arXiv

Group-kernel auto-calibration and group-patch k-space reconstruction: Fast MRI with time-variant B0 kernels partitioned into time-invariant subsets

Purpose: Pushing MRI speed further demands more spatially-encoded information captured per unit time, e.g., by superimposing additional field modulations during oversampled readout. However, this can introduce calibration errors and increase reconstruction time. Thus, we propose a continuous field calibration approach and an efficient k-space reconstruction technique. Theory and Methods: Our auto-calibration generalizes GRAPPA kernels to explicitly extract continuous B0 modulation kernels, solving interpolation relationships between two ACS regions differing only in the extra field modulation. The k-space locations sharing the same instantaneous image-space modulation are grouped, so that subsets of time-invariant kernels can be separately estimated, as a generalized solution for Wave-CAIPI/FRONSAC-type scans. This view further inspires a k-space subregion-wise reconstruction technique, as an efficient alternative to conventional hybrid-space reconstruction. At 9.4T, FLASH accelerated by a local B0 coil array and Wave-CAIPI were tested with retrospective undersampling. Results: Artifact-free images were reconstructed, under diverse rapid B0 modulation schemes, reaching maximum acceleration factors of 8-fold in 2D and 14.6-fold in 3D. Some nonlinear gradients modulation schemes reach similar sampling efficiency as linear gradients modulation. The proposed reconstruction shows potentials in reducing reconstruction time. Conclusion: Rapid B0 modulations and widely-adopted parallel imaging can share a common mathematical framework, and consequently, achieve similarly-robust reconstructions. Specifically, for scans using dynamic B0 and static RF kernels, not only signal encoding, but also auto-calibration and reconstruction can be performed in k-space. This paves the way to robustly remove eddy currents, and explore more complex B0 modulation strategies towards ultimate MRI speed.